CANDD cPCI420DC Datasheet

Corporate: www.cdtechno.com Product: www.cdpowerelectronics.com
cPCI420DC
420 Watt, 6U x 8HP, CompactPCI
Corporate: www.cdtechno.com
6U X 8HP
36-72 VDC Input Range
420 Watts Continuous Output
Complies with PICMG 2.11
R1.0 with 47 Pin I/O Connector
Hot-Swap Capable
The cPCI420DC is a high-reliability, 420 watt power supply for 6U Compact PCI™ systems. Developed to support hot-swap, redundant operation, the cPCI420DC is designed for compliance with PICMG™ 2.11 R1.0 Power Interface Specification with 47-pin I/O connector, as well as the underlying CompactPCI™ standards. Operating from 36-72VDC, this unit was developed with high-availability (HA)
Outputs Individually Protected
Against Overloads; Automatic Recovery
PCI VoltageArchitecture
(5V, 3.3V,+12V,-12V)
No Minimum Load
telecommunications applications in mind. Active current sharing and internal ORing diodes are included to support these and other applications requiring reliable, hot-swap performance and N+1 redundant configuration. The 8HP package and complement of agency approvals provide for a complete power solution for your CompactPCI™ system requirements.
SPECIFICATIONS, ALL MODELS
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Operating Voltage Vin 36 72 VDC
Input Voltage Withstand 34 75 VDC
Inrush Current I
INPUT
Efficiency η 48VDC input, 420W load 68 %
OUTPUT NUMBER RATED OUTPUT VOLTAGE MIN MAX REGULATION
V1 +5.0VDC 0A 50 A* +2%
V2 +3.3VDC 0A 40 A* +2%
V3 +12.0VDC 0A 12 A +4%
V4 -12.0VDC 0A 2.0 A +/-4%
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Voltage Adjustment V1 and V2 only +5 %
OUTPUT
Temperature Coefficient TC 0.02 %/°C
PARD 20MHz bandwidth 50 mV
Output Power 50°C max temp. 420 W
* Combined currents from outputs V1 & V2 not to exceed 60A.
i
VOUT RATED OUTPUT CURRENT
36VDC input 8 APK
72VDC input 16 APK
IOUT
all outputs or 1.0% P-P
whichever is greater
cPCI420-DC REV B 8/2002
P-P
)
F
F
F
SPECIFICATIONS, ALL MODELS
Current Share
Active current sharing is employed on outputs V1, V2, and V3. Accuracy exceeds 10% of maximum rated load. N Output V4 to share within 40% of maximum rated load by means of droop response.
Remote Sense
Outputs V1, V2, and V3 capable of compensating up to
0.5VDC of line drop. Unit automatically reverts to local sensing in the event that the sense leads are opened for any reason. Unit is protected against reversed or shorted sense leads.
Output Power
420W continuous maximum, with 400lfm airflow at a maximum ambient of 50°C. See Derating Chart on page 3 for additional data.
Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Over Voltage Protection
Output V1 OVP set at 6.0V ± 0.5V
4.3V ± 0.5V V4 OVP set at -13.5
DC. Output V3 OVP set at 13.5 +0.5VDC. Output
+0.5VDC. The power supply will shut
DC. Output V2 OVP set at
down and latch off under an OVP fault condition. Restart of the unit is accomplished by cycling of the input power.
Over Temperature Protection
Thermal switch shuts down the power supply in the event that critical temperatures are exceeded. Unit will automatically restart when acceptable temperatures are restored.
Output Fault Isolation
Output isolation diodes are present in all outputs to isolate faults within a failed power supply.
Synchronous Start
Interconnection of the Sync Start pin (pin 23) ensures that the outputs of parallel supplies will be enabled simultaneously to
max
= 4.
ensure sufficient source current in applications where the load current exceeds the capacity of a single power supply module.
Remote Inhibit (INH#)
Secondary referenced, active low, TTL compatible signal inhibits all outputs upon activation.
Power Fail Warning (FAL#)
Secondary referenced, active low, TTL compatible signal indicates output failure.
Enable (EN#)
Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Temperature Warning (DEG#)
Open collector indicates internal temperatures are approaching the thermal shutdown limit.
Fault Indicator
Red LED will be ON if output voltages are not within specification.
Power Present LED
Green LED will be ON when input voltage is present and above the minimum requirement.
Cooling
400 lfm of airflow required to maintain full output power at 0­50°C ambient. See Derating Chart below for additional data.
Temperature
0-70°C operating range with full output power achievable over the range of 0-50°C. See Derating Chart below for additional data. Storage temperature limits are –20 to +85°C.
Altitude
Operating: -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate.
450
400
350
300
250
200
150
Output Power (Watts
100
50
0
20 30 40 50 60 70
Product: www.cdpowerelectronics.com
DERATING CHART
Ambient Temp. ( Degrees C
NOTES: Data points are typical.
Power derating is load profile-dependent; data shown reflects output load currents reduced in direct proportion to the power derating.
400 L
200 L
100 L
)
cPCI420-DC REV B 8/2002