CANDD cPCI350DC Datasheet

cPCI350DC
cPCI350DC
CompactPCI SERIES
POWER: 350 Watt
SIZE: 6U x 8HP
COMPLIANCE: PICMG2.11 R1.0
FEATURES❁❁
6U X 8HP
36-75 VDC INPUT RANGE
350 WATT CONTINUOUS OUTPUT POWER
COMPLIES WITH PICMG™ 2.11 R1.0 WITH 47 PIN I/O CONNECTOR
OUTPUTS INDIVIDUALLY PROTECTED AGAINST OVERLOADS;
AUTOMATIC RECOVERY
HOT-SWAP CAPABLE
POWER ELECTRONICS DIVISION
Corporate: www.cdtechno.com product: www.cdpowerelectronics.com
PRODUCT DATA SHEET
PCI VOLTAGE ARCHITECTURE
(5V, 3.3V, +12V, -12V)
NO MINIMUM LOAD
The cPCI350DC is a high-reliability, 350 watt power supply for 6U Compact PCI™ systems. Developed to support hot-swap, redundant operation, the cPCI350DC is designed for compliance with PICMG™ 2.11 R1.0
47-pin I/O connector, as well as the underlying from 36-75VDC, this unit was developed with high-availability (HA) telecommunications applications in mind. Active current sharing and internal ORing diodes are included to support these and other applications requiring reliable, hot-swap performance and N+1 redundant configuration. The 8HP package and complement of agency approvals provide for a complete power solution for your CompactPCI system requirements.
AGENCY APPROVALS PENDING
Power Interface Specification
standards. Operating
with
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Ar izona 85706
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for users intended purpose and in users specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
cPCI 350DC 9/2001 REV C Page 1
Phone: 800.547.2537
Fax: 520.770.9369
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
C&D Technologies, (NCL)
Tanners Drive Blakelands North
Milton Keynes MK14 5BU UK
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
INPUT CHARACTERISTICS
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Operating Voltage Vin 36 75 VDC
Input Voltage With Stand 34 75 VDC
Inrush Current 36VDC input 18 APK
72VDC input 36 APK
Current Share
Active current sharing is employed on outputs V1, V2, and V3. Accuracy exceeds 10% of maximum rated load. N
max
=
4. Output V4 to share within 40% of maximum rated load by means of droop response.
Remote Sense
Outputs V1, V2, and V3 capable of compensating up to
0.5VDC of line drop. Unit automatically reverts to local sens­ing in the event that the sense leads are opened for any reason. Unit is protected against reversed or shorted sense leads.
Output Power
350W continuous maximum, with 400lfm airflow at a maxi­mum ambient of 50°C. Output power derates linearly to 175W at 70°C ambient or 200lfm of airflow at 50°C.
Overload Protection
Outputs are individually protected against overloads and in­definite short circuit with automatic recovery upon removal of the fault condition.
Over Voltage Protection
Output V1 OVP set at 6.0V ± 0.5V
DC. Output V2 OVP set at
4.3V ± 0.5VDC. The power supply will shut down and latch off under an OVP fault condition. Restart of the unit is ac­complished by cycling of the input power.
Over Temperature Protection
Thermal switch shuts down the power supply in the event that critical temperatures are exceeded. Unit will automati­cally restart when acceptable temperatures are restored.
Output Fault Isolation
Output isolation diodes are present in all outputs to isolate faults within a failed power supply.
Remote Inhibit (INH#)
Secondary referenced, active low, TTL compatible signal in­hibits all outputs upon activation.
Power Fail Warning (FAL#)
Secondary referenced, active low, TTL compatible signal in­dicates output failure.
Enable (EN#)
Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating con­nector.
Temperature Warning (DEG#)
Open collector indicates internal temperatures are approach­ing the thermal shutdown limit.
Fault Indicator
Red LED will be ON if output voltages are not within specifi­cation.
Power Present LED
Green LED will be ON when input voltage is present and above the minimum requirement.
Cooling
400 lfm of airflow required to maintain full output power at 0­50°C ambient. At 200 lfm, the output power is derated to 175W.
Temperature
0-70°C operating range with full output power achievable over the range of 0-50°C. Between 50°C and 70°C, output power derates linearly from 350W to 175W. Storage temperature limits are –20 to +85°C.
Page 2
Altitude
Operating: -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate.
cPCI 350DC 9/2001 REV C
Loading...
+ 2 hidden pages