camry EK-19A SERIES Instructions For Use Manual

Page 1
13EK-019E R2
CLEANING AND CARE
7
MEASURING CUP SCALES
INSTRUCTIONS FOR USE
E K - 1 9 A S E R I E S
ISO 9001:2008 CE RT IF IE D BY S
2. All plastic parts should be cleaned immediately after contact with fats,
spices, vinegar and strongly flavored/colored foods. Avoid contact with
acids citrus juices.
3. Always use the scale on a hard, flat surface. DO NOT use on carpet.
.
.
.
.
.
1.Clean the product with a soft, slightly damp (not wet) cloth. Remove
container to clean up. Ensure container is empty before removing; Do
not put scale into water. The scale is not water-proof.
4 DO NOT strike, shake or drop the scale.
5 The scale is precise instrument. Please treat with care.
6 Put the scale in cool and dry place.
7 If fail to switch on the scale, check whether battery is installed, or
battery power is low.
8 For family use only. DO NOT use for commercial purpose.
×
FRIENDLY REMINDER
When pouring liquid from the measuring cup, please remove the measuring
cup from scale body. If scale body has to be held when pouring the liquid,
please press the edge of the measuring cup with your thumb to avoid the
prolapse. Please see the diagram.
Page 2
1.Measuring cup function
2.Indicate volume of water,milk,oil and flour
3.Two weight units convertible: g, lb:oz
4.Three volume units convertible: ml, fl'oz, cup
5.Tare,Zero function
6.Low battery power/Overload indication
7.Auto off
FEATURES
TO I NSTA LL OR R E PLAC E BAT TERY
Open the battery compartment cover : A. Take out the used battery with the aid of a sharp object, as shown in picture. B. Install new battery by putting one side of the battery beneath the battery baffle and then pressing down the other side.
1 2
LCD
Battery baffle
1x3V CR2032 lithium battery . Remove isolation sheet
before use.
included)
Volume unit( )fl'oz
Volume unit(ml)
Weight unit(g)
Weight unit(lb:oz)
LC D
PRODUCT OUTLINE
Body
Button
Measuring cup
FUNCTION BUTTON
Mode selector (Arrow keys)
Tare function
Mode selector (Arrow keys)
Press "MODE"
Press "MODE"
Press "MODE"
Press "MODE"
Press "MODE"
Water modevolume Milk volume mode
Oil volume mode
Flour volume mode
Weighing mode
MODE CONVERSION
The product will be in weighing mode after turn on. Please press MODE to switch mode (weighing, water volume, milk volume, oil volume and flour volume ). Then press UNIT to select the unit you need.
(Please observe the polarity.)
Mode conversion
Unit conversion
MODE UNIT
ON/OFF
ZERO
MODE
UNIT
:
=
:
=
ON/ OFF
ZER O
ON/ OFF
ZER O
:
=
The b atter y compa rtmen t cover p ositi on of dif feren t model s may be di fferen t ( or ), ple ase pre vail in a ctual i tem.
Page 3
43
ON/ OFF
ZER O
TO MEASURE
ON/ OFF
ZER O
1. Weighing mode
A. Place the scale on a solid and flat
surface. .
B. Press to turn on.
C. Wait until LCD shows "0".
D. Load weighing object on scale to start
weighing, LCD wil l show the weight
reading.
UNIT CONVERSION
If the scale is with both measuring systems of Metric (kg, g) and Imperial (lb, oz)
1. Weight unit conversion:
Press UNIT button to convert weight unit between Metric and Imperial system after entering weighing mode.
Press"UNIT"
Remark: The unit system of scale depends on sales destination or the requirement of distributor.
Press"UNIT"
ON/ OFF
ZER O
Pre ss
Pre ss "MO DE"
Pre ss"UN IT"
Pou r milk
2. Volume mode
ON/ OFF
ZER O
A.Place the container.Place the scale
on a solid and flat surface.
B. Press to turn on the scale.
For instance, unit as following steps:
measuring milk by CUP
C. Wait until LCD shows "0", press MODE button to select milk mode. D.Press UNIT button to set CUP unit. E. Pour milk into the container, LCD shows the volume of liquid.
2.Volume unit conversion
For instance,under water volume mode:
Press UNIT button to convert volume unit between ml (fl'oz) and CUP after entering volume mode.
Load weighing object
Page 4
"ZERO" OR "TARE" FUNCTION
To weigh different loads consecutively without removing loads from the scale.
Put first Load on the scale, get weight reading. Press button to reset the
LCD reading to "0" before adding next load. You can repeat this operation.
5
1.
2.
WARNING INDICATORS
1. Replace new battery.
2. Scale overload. Remove item to avoid
damage.Max.weight capacity is
indicated on the scale.
MANUAL SHUT OFF
Auto shut-off occurs if no operation
or shows the same weight reading
for 30 seconds.
AUTO SHUT OFF
6
Condition 1: "TARE" function
When total sum of all loads on scale>0g
Condition 2: "ZERO" function
When total sum of all loads on scale<0g
LCD will show ----- or 0g each time is pressed. ----- means processing, please wait for a moment. When 0g and icon T on lower left corner of LCD show up together, it means TARE function is active.Max. Capacity is reduced by total weight of all loads.
ON/ OFF
ZER O
ON/ OFF
ZER O
Pre ss
ON/ OFF
ZER O
Pre ss
ON/ OFF
ZER O
ON/ OFF
ZER O
LCD display will show --- or 0g each time is pressed. "----" means processing, please wait for a moment. When LCD shows "0g", it means "ZERO" function is active. Max capacity remains unchanged.
ON/ OFF
ZER O
ON/ OFF
ZER O
To maximize battery life, please press
button for 3 seconds to turn off
scale after use.
Loading...