1. Safety Instructions
For Household Use Only
1. Only use the vacuum cleaner indoors on dry surfaces.
to ensure that they do not play with the appliance.
5. Use only as described in this manual. Use only the manufacturer’s recommended attachments.
6. Do not use the vacuum cleaner with a damaged cord or plug. Do not use the vacuum cleaner if it has been dropped, damaged, left outdoors or dropped into water. Return the vacuum cleaner to a Vax Authorised Service Agent for examination, repair or adjustment.
7. Do not pull or carry by the cord. Do not use the cord as a handle, close a door on the cord or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
or use in the presence of explosive liquids or vapours.
14. Do not vacuum up hard or sharp objects such as glass, nails, screws, coins, etc.
15. Do not use without the filters in place.
16. Use extra care when vacuuming on stairs.
17. Keep vacuuming area well lit.
18. Store the vacuum cleaner indoors in a cool, dry area.
19. Turn off the switch before unplugging.
WARNING: Always switch off and unplug the vacuum cleaner from the electrical outlet before assembling, opening or emptying the dirt container, or before connecting/disconnecting the attachments.
CAUTION: The vacuum cleaner is a very powerful unit. Before plugging the cord into the outlet make sure the switch is in the ‘off’ position. Hold the vacuum cleaner firmly when starting and in use.
IMPORTANT: If the inlet or hose is blocked, switch off the vacuum cleaner and remove the blockage(s) before restarting.
IMPORTANT: Cleaning filters improves vacuum performance. Make sure all filters are replaced back into the vacuum cleaner before using. This vacuum cleaner is intended for household use only and not for commercial or industrial use.
PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER USE.
Motor Thermostat IMPORTANT: The motor is equipped with a
thermal cut-out. If, for any reason the vacuum cleaner should over-heat, the thermostat will automatically turn the unit off. Should this occur, unplug the vacuum cleaner from the electrical outlet and turn off the switch. Remove the dirt container and empty. Clean the filters. Allow the cleaner to cool for approximately one (1) hour before re-starting.
Replacement Filters & Belts
Replacement filters and belts are available from your Vax stockist or Vax direct. Phone VAXCARE or visit www.vax.com.au
Fig.7/3
Fig.8/1
9. Troubleshooting
WARNING: to reduce risk of personal injury
unplug vacuum cleaner before servicing.
PROBLEM: Cleaner won’t run
Cause: Not properly plugged into electrical
outlet.
Solution: Plug in firmly. Cause: No electricity in electrical outlet.
Solution: Check fuse or breaker. Cause: On/off switch not turned on.
Solution: Push on/off switch to on. Cause: Motor thermostat tripped.
Solution: Reset motor thermostat (see page 2). Cause: Blown fuse/tripped breaker.
Solution: Reset circuit breaker or replace fuse.
PROBLEM: Cleaner won’t pick up
Cause: Full or clogged dirt container. Solution: Clean dirt container.
Cause: Wrong pile height setting. Solution: Adjust brushbar height adjuster .
Cause: Clogged nozzle. Solution: Remove obstruction.
Cause: Clogged dirt inlet. Solution: Remove vacuum cleaner head
cover and remove obstruction.
Cause: Clogged hose. Solution: Remove obstruction.
Cause: Broken belt. Solution: Replace belt.
Cause: Hose not inserted fully. Solution: Push hose in securely.
Cause: Dirty filters. Solution: Clean/change filters.
PROBLEM: Accessories won’t pick up
Cause: Accessories not attached correctly. Solution: Refer to page 5 for fitting
information.
PROBLEM: Cleaner picks up moveable rugs or is too hard to push
Cause: Wrong pile height setting. Solution: Adjust setting on brushbar height
adjuster.
PROBLEM: Brushbar does not turn
Cause: Broken belt. Solution: Replace belt.
Cause: Belt installed incorrectly. Solution: Check belt.
PROBLEM: Air flow restricted with attachment use
Cause: Attachment use restricts air flow. Solution: Check attachment for blockage.
Cause: New carpet debris clogging air path. Solution: Remove obstruction.
4. Remove the worn or broken belt from the motor drive shaft.
5. Remove any residue in the belt area before installing a new belt.
6. Loop the new belt first over the motor drive shaft and then over the agitator pulley.
7. Insert the right side of the brushbar first by placing the end cap down in the slot and then do the same with the left side. Press firmly to make sure that each end is completely inserted.
8. Check to make sure that the belt is centred on the agitator pulley and that the brushbar turns.
9. Replace the vacuum head cover by screwing in the four (4) screws on the underside of the vacuum cleaner.
8. Clearing Blockages
1. Switch the vacuum cleaner off and disconnect the power plug from the electrical outlet.
2. The flexible hose can be disconnected from the vacuum cleaner by turning anti­clockwise and pulling away from the machine (Fig.8/1). Remove any blockages found then reconnect the hose securely.