Camplex CMX-3GSFP-TR Users Guide

Page 1
Mini 1-Channel Uni-Directional 3G-SDI over Fiber Extender Set
CMX-3GSFP-TR
User Manual and Specifications
Page 2
2 x 5V Mini XLR Power Supply
3G-SDI Over Single Mode Fiber Optic Extender
Connectors: 75Ω BNC Female & simplex LC Female
TV Signal Standard: SMPTE 424M, 292M, 259M, 297M, 305M, 310M,
M2S, DVB-ASI, DVB-SSI and Others
Signal Level: 800mV Nominal
Transmission Distance: up to 30km/18.6 miles
Reflection Loss: > 15dB
Operating Temperature: -40°F - 115°F (-40°C - 45°C)
Power Supply: 5V Mini XLR Power Supply
Power Consumption: 3W
TX Dimensions (LxWxH): 4.55 x 1.03 x 1.01in
RX Dimensions (LxWxH): 4.23 x 1.02 x 1.01in
The Camplex CMX-3GSFP-TR is a mini 1-channel uni-directional 3G-SDI over fiber extender set that sends 3G-SDI signals up to 1080p@60Hz over one LC single mode fiber up to 18.6 miles. The compact lightweight design is perfect for camera and computer interfaces where space is limited.
DESCRIPTION
PACKAGE CONTENTS
Sends 3G-SDI Signals Over One LC Single Mode Fiber up to 30km/18.6 Miles Supports Resolutions up to 1080p@60Hz Supports SMPTE-424M (3G-SDI), SMPTE-292M (HD-SDI), and SMTPE-259M (SD-SDI) Compact and Easy to Install Data Rate from 19.4Mbps up to 2.97Gb/s SMPTE 424M (2.97Gb/s) Clock Recovery 5V Power Supply with Mini XLR Connector Supports Automatic Cable Equalization Based on the Data Rate Detected
FEATURES
CMX-3GSFP-TR
SPECIFICATIONS
Page 3
CMX-3GSFP-TR
CONNECTION DIAGRAM:
LC Single Mode Fiber
3G SDI
Video
Source
75 Ohm BNC Cable
5V Mini XLR
Power Supply
75 Ohm BNC Cable
5V Mini XLR
Power Supply
3G SDI
Video
Source
Page 4
The unit should be serviced by qualified service personnel if:
(a) The DC power supply cord or AC adaptor has been damaged
(b) Objects or liquids have gotten into the unit
(c) The unit has been exposed to rain
(d) The unit does not operate normally or exhibits a marked change in performance; The unit has been dropped or the cabinet is damaged.
(2) Servicing Personnel: Do not attempt to service the unit beyond that described in these operating instructions. Refer all other servicing to authorized servicing personnel.
(3) Replacement parts: When parts need replacing ensure the servicer uses parts specified by the manufacturer. Unauthorized substitutes may result in fire, electric shock, or other hazards.
(4) Safety check: After repairs or service, ask the servicer to perform safety checks to confirm that the unit is in proper working condition.
Damage requiring service:
PRODUCT SERVICE
Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
Never spill liquid of any kind on or into this product.
Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit.
Do not attach the power supply cabling to building surfaces.
Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged.
Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it.
To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit
Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install the unit:
SAFETY PRECAUTIONS
WARRANTY
1 Year
CMX-3GSFP-TR
812 Kings Highway, Saugerties, NY 12477 | 1.800.445.7568 | sales@camplex.com
100% Employee Owned Division of Tower Products Incorporated
Loading...