Campbell Scientific SDM-CD16S Specifications

PRODUCT
With an SDM-CD16S, your data logger can controldc devices that have a relatively high-powered load, such as solenoids, solenoid valves, dc motors, stepper motors, lights, horns,
Allows the data logger to automatically turn devices on or off when a threshold (for example, temperature or water depth) has been reached
This relay driver provides 16dc voltage outputs that can be switched on and off manually or under data logger control. The SDM-CD16S's toggle switch has three positions: MANUAL, OFF, and AUTO.
In the MANUAL position, outputs are controlled by the position of the individual rocker switches.
In the OFF position, all outputs are off. In the AUTO position, the state of the relays is controlled by
the SDM commands from the data logger or by the logic control inputs.
Separate inputs for power-to-outputs (48 Vdc maximum) and power-to-SDM-CD16S logic (7 to 48 Vdc) allow the option of
16-Channel Solid-State DC Controller
SDM-CD16S
Expands Data Logger Control Capacity
For dc devices with higher current loads
Overview
Benefits and Features
Detailed Description
heaters, and fans.With a voltage range of up to 48 Vdc and a maximum current output per channel of 2 A, the SDM-CD16S can drive up to 100 W of power on each channel.
Provides a manual override Includes LEDs for a visual indicator of active outputs Drives up to 100 W of power on each channel
powering the logic from the data logger’s 12 V while switching a higher voltage.
SDM Operation
The SDM-CD16S is a synchronously addressed data logger peripheral. Data logger control ports 1, 2, and 3 are used to address the SDM-CD16S, then clock out the desired state of each of theeight control ports. Up to 15 SDM-CD16S devices may be addressed, making it possible to control a maximum of 256 ports from the first three data logger control ports.
Data Logger Connection
The CABLE5CBL-L is recommended for connecting the module to the data logger. A 1-ft cable length should be sufficient when both data logger and SDM-CD16S are housed within an
For comprehensive details, visit: www.campbellsci.com/sdm-cd16s
ENC12/14 enclosure; a 2-ft length may be required if the data logger and SDM-CD16S are housed at opposite ends of an ENC16/18 Enclosure. The cable length should be as short as
Function Allows the data logger to control
dc devices that have a relatively high-powered load, such as solenoids, solenoid valves, dc motors, stepper motors, lights,
horns, heaters, and fans. Number of Channels 16 Isolation Optically isolated between the
inputs and outputs Logic Power Voltage 7 to 48 Vdc Logic Current Drain (@ 12
Vdc)
2.5 mA per active LED (manual or auto) 15 mA quiescent
Toggle Switch Individual dip switches for
manual
Specifications
possible. Typically, the maximum cable length is 20 ft. Contact Campbell Scientific if the length needs to be longer.
MANUAL, OFF, AUTO Supply Voltage for Output 48 V max (dc only) Operating Voltage 12 Vdc Maximum Current 2 A (per channel)
10 A fused (all channels total) Fuse 3 AG 10 A Actuation/Release Times 8 μs/200 μs Operating Temperature -40° to +70°C Maximum Cable Length 6 m (20 ft) total to all SDM devices
(Contact Campbell Scientific if longer lengths are necessary.)
Dimensions 24.1 x 12.7 x 6.4 cm (9.5 x 5.0 x 2.5
in.)
Weight 771.1 g (1.7 lb)
For comprehensive details, visit: www.campbellsci.com/sdm-cd16s
© 2020 Campbell Scientific, Inc. | 08/13/2020
Loading...