Campbell Scientific SC929 User Manual

INSTRUCTION MANUAL
SC929 RS232 Interface
9/96
Copyright (c) 1996
Campbell Scientific, Inc.

Warranty and Assistance

The SC929 RS232 INTERFACE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.
Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers wi thin their territories. Please visi t www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____ 815 West 1800 North Logan, Utah 84321-1784
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

SC929 RS232 INTERFACE

The SC929 temporarily connects a Campbell Scientific battery-powered PC to a datalogger for data retrieval and program transfer. This interface is typically used in remote locations.

1. SPECIFICATIONS

Operating temperature: -25° C to +50° C
Power: Powered by datalogger; current
consumption typically 8 mA
Connections: 9-pin male; connects to
datalogger
9-pin female; configured as DCE,
connects to AT-type portable PC
Length: 2 m (6 ft.) cable fitted with two
9-pin ‘D’ connectors
Weight: 225 g (8 oz.)

2. APPLICATION

The SC929 provides a two-way conversion between datalogger logic levels (0 V low, 5 V high) and RS232 logic levels (e.g., -8 V low, + 8 V high). It may be used in applications where a battery-powered laptop is taken to the field to communicate with the datalogger (e.g., transfer data or programs, set clock, monitor data, etc.). It provides a neat, single-cable alternative to an SC12 cable, 7026 cable, and an SC32A Interface, but with some differences (see adjoining note).
NOTE:
There are some significant differences between the SC929 and the SC32A:
a. The SC929 does not provide opto-
isolation. To prevent ground loops, do not use the SC929 with a computer directly connected to power, powered AC, or other ground-referenced power supplies.
b. Unlike the SC32A, the SC929
consumes significant levels of power from the datalogger. To avoid unnecessary power drain, disconnect the SC929 from the datalogger serial I/O port when the SC929 is not in use.
c. The SC929 does not have the jumper
option that is available with the SC32A and in certain situations odd characters may appear on the PC screen. However, this will not affect the correct operation of Campbell Scientific software.
12V 12V
DIFFSEAG H L AG H L AGH L AG GGE3 AG
4 5 6
78 910 1112
CAMPBELL SCIENTIFIC INC.
12 34 56
SE
1 2 3
AG H L AG H L AGH L AG GGE1 E2
DIFF
GGGG
SWITCHED
12V
SWITCHED
12V
CONTROL
EARTH
G 5V5VP1 P2 C8C7C6C5C4C3C2C1
G 12V
POWER
IN
CR10X
WIRING PANEL NO.
SERIAL I/O
MADE IN USA
FIGURE 1. The SC929 connects the datalogger’s Serial I/O with a laptop’s serial port for
two-way communication.
1
SC929 RS232 INTERFACE
This is a blank page.
2
This is a bla nk page.
Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES www.campbellsci.com info@campbellsci.com
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
www.csafrica.co.za
sales@csafrica.co.za
Campbell Scientific Australia Pty. Ltd. (CSA)
PO Box 444
Thuringo wa Cent ra l QLD 4812 AUSTRALIA www.campbellsci.com.au
info@campbellsci.com.au
Campbell Scientific do Brazil Ltda . (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br
suporte@campbellsci.com.br
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
www.campbellsci.ca
dataloggers@campbellsci.ca
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk
sales@campbellsci.co.uk
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
FRANCE
www.campbellsci.fr
campbell.scientific@wanadoo.fr
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
08013 Barcelona
SPAIN www.campbellsci.es info@campbellsci.es
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
Loading...