Campbell Scientific SC532A User Manual

SC532A 9-Pin Peripheral to
RS232 Interface
Revision: 4/09
Copyright © 1998-2009
Campbell Scientific, Inc.

Warranty and Assistance

The SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.
Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country.
To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____ 815 West 1800 North Logan, Utah 84321-1784
For all returns, the customer must fill out a “Declaration of Hazardous Material and Decontamination” form and comply with the requirements specified in it. The form is available from our website at completed form must be either emailed to shanna@campbellsci.com to 435-750-9579. Campbell Scientific will not process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer’s expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees.
www.campbellsci.com/repair
. A
or faxed
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
SC532A Table of Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections.
1. Function................................................................................... 1
2. Physical Description............................................................ 1
3. Specifications........................................................................ 2
4. Hardware Connections....................................................... 3
5. Operation................................................................................. 3
6. Portable Battery Power....................................................... 4
Appendices
A. Pin Description
..................................................................A-1
B. Schematic............................................................................B-1
C. Component Location.......................................................C-1
Figures
1. SC532A Case Top ......................................................................................1
2. Connection Block Diagram.........................................................................3
3. DC Cable for 12 VDC Datalogger Connection...........................................3
Tables
1. SC532A Power Supply Connector..............................................................5
2. CSI Peripherals and Their Maximum Operating Current Requirements....5
3. SC532A Jumper Guide...............................................................................5
A-1. SC532A Pin Description.................................................................... A-1
A-2. DTE 25 Pin Configuration................................................................. A-2
A-3. DTE 9 Pin Configuration................................................................... A-2
This is a blank page.

SC532A 9-Pin Peripheral to 9-Pin RS232 Interface

1. Function

The SC532A Peripheral Interface connects an IBM® PC compatible computer, with appropriate software, to certain Campbell Scientific datalogger peripherals including phone modems (COM200, COM210, COM220), storage modules (SM4M/16M, SM192/716), MD9 multi-drop interface, and Seimac SCD/Argos satellite transmitter.
Like the SC532, the SC532A supplies 5 VDC on the PERIPHERAL connector (pin 1) to power 5V peripherals like the SM16M. The SC532A also supplies 12 VDC (on pin 8) to power 12V peripherals such as the COM220, high-speed modems, and certain radios.
The SC532A has an internal jumper that selects either “SC532” or “PROG” mode. PROGRAM mode is for configuring the Seimac SCD/Argos satellite transmitter. The factory setting is “SC532” which is appropriate for most applications. The case can be opened by twisting a 1/8 inch (3 mm) standard screwdriver in the four seam slots.

2. Physical Description

An SC12 and a 10873 cable are shipped with the SC532A. The SC12 cable connects the SC532A 9-pin female D-Sub labeled “PERIPHERAL” to your CSI peripheral. The 10873 cable connects a PC COM port to the other 9-pin connector labeled “PC.”
The SC532A is typically powered by the 15966 wall charger (purchased separately). This wall charger supplies 12VDC @ 800 mA which is sufficient for any listed peripheral. The power jack on the SC532A allows convenient wall charger replacement. If only 5V peripherals are used, an AC adapter outputting just 6 VDC with enough current capability and having the correct barrel connector size and polarity will do (see Tables 1 and 2).
The 14020 and 14291 field cables are available (see Portable Battery Power section) for remote sites lacking 120 VAC. The 14020 and 14291 field cables are purchased separately.
PERIPHERAL
Logan, Utah
SC532A
RS232 to CS I/O
POWER
SN:
PC
MADE IN USA
FIGURE 1. SC532A Case Top
1
SC532A 9-Pin Peripheral to 9-Pin RS232 Interface

3. Specifications

Input voltage (to POWER jack)
Output voltages +5 VDC ± 0.075 VDC on PERIPHERAL connector
Current available to 5 V peripheral
Current available to 12 V peripheral
RS232 output levels +10 VDC ± 1 VDC
RS232 input levels ± 30 V maximum
A) 5 Volt Peripherals require 6 17 VDC B) 12 Volt Peripherals require 12 17 VDC Barrel connector: inner bore (+), outer sleeve (−) (factory 120 V AC adapter supplies 12 VDC unregulated @ 1A)
pin 1 and 6 17 VDC on PERIPHERAL connector pin 8, depending on AC adapter in use (12 VDC unregulated with factory AC adapter)
+5 VDC @ 120 mA maximum at 25°C derate 12 mA for each AC adapter Volt above 9 VDC derate 1 mA for each °C above 25°C
Factory provided AC adapter supplies unregulated 12 VDC @ 1 Amp
10 VDC ± 1 VDC Maximum output impedance = 1100 Ω
Low threshold 0.8 V High threshold 3.5 V Input impedance at least 3000 Ω
9-pin inputs
9-pin outputs
Current drain 5 mA typical quiescent
Port Configuration
Dimensions 4 5/8 x 1 3/4 x 1 inches (allow up to 1 1/4 inches
Weight 1 1/4 pounds with AC adapter
Low 1 V; High 3.5 V
Low 0.5 V; High 3.5 V
10 mA max imum quiescent
PC: 9-pin D-Subminiature Female configured as DCE.
Peripheral: 9-pin D-Subminiature Female connects to peripheral through SC12 Two Peripheral Connector Cable supplied with the SC532A.
extra on 1 3/4 dimension for power connector strain relief)
2
Loading...