ThePS12LA, PS512M, CH12R, CH512R POWER SUPPLIES AND
CHARGING REGULATORS are warranted by CAMPBELL SCIENTIFIC,
INC. to be free from defects in materials and workmanship under normal use
and service for twelve (12) months from date of shipment unless specified
otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s
obligation under this warranty is limited to repairing or replacing (at
CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer
shall assume all costs of removing, reinstalling, and shipping defective products
to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will
return such products by surface carrier prepaid. This warranty shall not apply
to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to
modification, misuse, neglect, accidents of nature, or shipping damage. This
warranty is in lieu of all other warranties, expressed or implied, including
warranties of merchantability or fitness for a particular purpose. CAMPBELL
SCIENTIFIC, INC. is not liable for special, indirect, incidental, or
consequential damages.
Products may not be returned without prior authorization. To obtain a
Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC,
INC., phone (435) 753-2342. After an applications engineer determines the
nature of the problem, an RMA number will be issued. Please write this
number clearly on the outside of the shipping container. CAMPBELL
SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
Non-warranty products returned for repair should be accompanied by a
purchase order to cover the repair.
This is a blank page.
PS12LA, PS512M, CH12R, CH512R
Power Supplies and Charging Regulators
1. General Description
The PS12LA and PS512M are 12 volt power supplies that include the charging
regulator and a 7 amp hour battery. The CH12R and CH512R are charging
regulators that are used with a Campbell Scientific battery pack such as the
BP12 or BP24 or with a user-supplied battery. Charging power is typically
supplied by a CSI Model 9591 AC Transformer or by an MSX10 or MSX20
solar panel.
The PS512M and CH512R also have two 9-pin connectors that provide a null
modem for use in a site, without a datalogger, that connects and powers two
Campbell Scientific peripherals that would normally be connected to a
datalogger. These peripherals are typically modems linking different
communications technologies; e.g., telephone to radio.
charge for 12 V Battery
Temperature Compensation Range:-40 to +60ºC
Charging Current Limit:1.2 Amps typical
Power Out (+12 terminals)
Voltage:Unregulated 12 V from Battery
Current Limited w / 3 A Thermal Fuse:
Battery Packs
Operating Temperature Range:-40 to +60ºC
Capacity:
PS12LA7 Amp hours
BP1212 Amp hours
BP2424 Amp hours
AC Transformer: CSI Model No. 9591
Input Voltage:120 VAC
Output Voltage:18 VAC RMS
Output Current (max):1.2 Amps RMS
Protection (automatic reset):
UL Approval:UL-1950
> 3 A @ < 20°C
3 A @ 20°C
2.1A @ 50°C
1.8 A @ 60°C
85°C thermal reset breaker
1
PS12LA, PS512M, CH12R, CH512R Power Supplies and Charging Regulators
3. Wiring
An internal or external battery is connected to the charger by means of the INT
(Internal) or EXT (External) connectors, as shown in Figure 1. An “external
battery” cable comes with the charger that allows connecting another battery to
the charger to provide power if the main battery is removed. The red lead
connects to the positive battery terminal and the black lead connects to the
negative terminal.
WARNING
CAUTION
Reversal of polarity of external battery will damage the
PS12LA or PS512M.
It is possible to leave two batteries connected. The battery connections are
diode isolated (Figure 3-2); however, if one of the batteries fail, it could draw
all the charging current and the other battery will be discharged.
A battery must be attached for the charger to function
correctly as a power supply.
The leads from the transformer or solar panel are connected to the CHG
terminals. Polarity does not matter; either lead can be connected to either
terminal.
The wires that connect power to the datalogger and/or peripherals are
connected to the +12 and ground (
) terminals.
To Battery
From Transformer or Solar Panel {
To Datalogger or peripherals {
2
These look identical
when unplugged
OFF
INT
EXT
CHG
CHG
CHG
+12
+12
BATT
ON
FIGURE 1. Wiring to Charger
PS12LA, PS512M, CH12R, CH512R Power Supplies and Charging Regulators
These
INT
look
identical
when
BATT
EXT
unplugged
Charging
Regulator
OUT
IN
3 A
Thermal
Fuse
FIGURE 2. Simplified Charging Circuit Schematic
4. Null Modem on PS512M and CH512R
The PS512M and CH12R have two 9-pin CS I/O ports on them with a null
modem between them. The ports are used to connect two 9-pin devices that
would normally be connected to the CS I/O port on a Campbell datalogger.
The charger supplies 12 volts and 5 volts to the appropriate pins on the
connector for powering the connected devices.
OFF
CHG
ON
CHG
CHG
+12
+12
CAUTION
This cannot be used as a null modem between two RS-232
devices.
3
PS12LA, PS512M, CH12R, CH512R Power Supplies and Charging Regulators
+5 V
1
6
2
7
3
8
4
9
5
1
2
7
3
8
4
9
5
+5 V
GND
HS
Ring
+12 V
RX
TX
ME
+12 V
1.85 A
Thermal
Fuse
Ring
RX
TX
ME
FIGURE 3. Null Modem Connections