TheHUB-SDM5 is warranted by CAMPBELL SCIENTIFIC, INC. to be free
from defects in materials and workmanship under normal use and service for
twelve (12) months from date of shipment unless specified otherwise.
Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation
under this warranty is limited to repairing or replacing (at CAMPBELL
SCIENTIFIC, INC.'s option) defective products. The customer shall assume
all costs of removing, reinstalling, and shipping defective products to
CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will
return such products by surface carrier prepaid. This warranty shall not apply
to any CAMPBELL SCIENTIFIC, INC. products which have been subjected
to modification, misuse, neglect, accidents of nature, or shipping damage. This
warranty is in lieu of all other warranties, expressed or implied, including
warranties of merchantability or fitness for a particular purpose. CAMPBELL
SCIENTIFIC, INC. is not liable for special, indirect, incidental, or
consequential damages.
Products may not be returned without prior authorization. The following
act information is for US and International customers residing in countries
cont
served by Campbell Scientific, Inc. directly. Affiliate companies handle
repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company
serves your country. To obtain a Returned Materials Authorization (RMA),
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an
applications engineer determines the nature of the problem, an RMA number
will be issued. Please write this number clearly on the outside of the shipping
container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 W
Logan, Ut
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
est 1800 North
ah 84321-1784
Page 3
HUB-SDM5 Table of Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use
the Adobe Acrobat® bookmarks tab for links to specific sections.
The HUB-SDM5 is a junction box and is used to connect multiple
Synchronous Device for Measurement (SDM) or SDI-12 devices/peripherals to
a single Campbell Scientific, Inc. datalogger. The HUB-SDM5 consists of an
environmental enclosure with six weather resistant bulkhead fittings and five
terminal strips.
2. HUB-SDM5 Specifications
Terminal Strips:
Three spring-loaded guillotine connections per terminal; two terminals in
common through a jumper creates five banks
Operating Temperature:
-55°C to +85°C
Operating Humidity:
Noncondensing 0% – 95%
Dimensions:
Length:17.8 cm (7.0”)
Width:19.7 cm (7.75”)
Depth:13.3 cm (5.25”)
Weight:
0.82 kg (1.8 lbs)
3. General
Inside the HUB-SDM5 enclosure are five pairs of terminal strips. These
terminal strips are mounted on a DIN rail and an orange end cap separates each
pair. Each pair of terminal strips is connected to each other by means of a
jumper. The terminal strips are used to connect up to six wires to each other.
The wires are secured to the terminal by a spring-loaded guillotine.
4. Installation and Wiring
A U-bolt is used to mount the HUB-SDM5 to a 1.25 inch NPT pipe.
The spring-loaded guillotines are opened with a small flat blade (2.5 X 50 mm)
screwdriver (p/n 8125). Orient the screwdriver blade so that the blade edge is
perpendicular to the orange separators. Gently insert the small flat blade
1
Page 6
HUB-SDM5
4.1 Wiring SDM Devices
screwdriver into the square slot located next to the circular wire port until it
bottoms out. For the cluster of four wire ports located on the left hand side of
the HUB-SDM5, the guillotine release slot is located to the right of the wire
port. For the wire ports on the right hand side of the HUB-SDM5, the
guillotine release slot is located to the left of the wire port. Once the
screwdriver has been completely inserted and has bottomed out, firmly press
the screwdriver down until the guillotine snaps open. Insert and hold the wire
as the screwdriver is removed.
Before connecting the SDM signal cable to the terminals, strip the wire
insulation back to expose ¼ inch of bare wire. Feed the cable through the
bulkhead fitting. Neatly separate the five wires into the following order, SDM
data, SDM clock, SDM enable, SDM ground, and SDM shield.
To CSAT3 #1
To CSAT3 #2
Sealed Bulkhead fitting
To LI-7500 #1
To LI-7500 #2
To Datalogger
FIGURE 1. HUB-SDM5 connecting four SDM devices to a datalogger.
2
Page 7
HUB-SDM5
SDM Data
SDM Clock
SDM Enable
SDM Ground
SDM Shield
SDM Devices
FIGURE 2. HUB-SDM5 terminal strip connecting four SDM devices to a datalogger.
Datalogger or second
HUB-SDM5
4.2 Wiring SDI-12 Devices
Before connecting the SDI-12 signal/power cable to the terminals, strip the
wire insulation back to expose ¼ inch of bare wire. Feed the cable through the
bulkhead fitting. Neatly separate the four wires into the following order, SDI12 data, SDI-12 power, SDI-12 ground, SDI-12 shield.
To SDI-12 sensor#1
To SDI-12 sensor#2
To SDI-12 sensor#3
Sealed
Bulkhead
Fitting
To
Datalogger
FIGURE 3. HUB-SDM5 connecting three SDI-12 devices
to a datalogger.
3
Page 8
HUB-SDM5
r
SDI-12 Data
SDI-12 Powe
SDI-12 Ground
SDI-12 Shield
SDI-12 Devices
Datalogger or second
HUB-SDM5
FIGURE 4. HUB-SDM5 terminal strip with SDI-12 devices
5. Generic Junction Box
The HUB-SDM5 can be used as a generic junction box. In its default
configuration, six, five conductor cables can be connected to each other.
Three, ten conductor cables can be connected to each other by removing the
jumper between the terminal strips. Use a small screwdriver to pry the jumper
out.
6. Maintenance
There are no user-serviceable parts in the HUB-SDM5. Make sure that all
unused bulkhead fittings are sealed with a plug and that the lid is tightly
fastened.
connected to a datalogger.
4
Page 9
This is a bla nk page.
Page 10
Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES
www.campbellsci.com
info@campbellsci.com
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
www.csafrica.co.za
sales@csafrica.co.za
Campbell Scientific Australia Pty. Ltd. (CSA)
PO Box 444
Thuringo wa Cent ra l
QLD 4812 AUSTRALIA
www.campbellsci.com.au
info@campbellsci.com.au
Campbell Scientific do Brazil Ltda . (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br
suporte@campbellsci.com.br
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
www.campbellsci.ca
dataloggers@campbellsci.ca
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk
sales@campbellsci.co.uk
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
FRANCE
www.campbellsci.fr
campbell.scientific@wanadoo.fr
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
08013 Barcelona
SPAIN
www.campbellsci.es
info@campbellsci.es
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.