PRODUCT
The HMP155A provides reliable relative humidity (RH) and
temperature measurements for a wide range of applications.
It uses a HUMICAP®180R capacitive thin film polymer sensor
to measure RH over the 0 to 100% RH range. A PRT measures
temperature over the -80° to +60°C range. This rugged,
accurate temperature/RH probe is manufactured by Vaisala.
Well-suited for long-term, unattended applications
Accurate and rugged
The HMP155A uses a HUMICAP180R capacitive thin film
polymer sensor to measure RH, and a PRT to measure
temperature.
To reduce the current drain, power can be supplied to the
HMP155A only during measurement when the sensor is
Electromagnetic
Compatibility
Complies with EMC standard
EN61326-1 Electromagnetic
Filter Description Sintered PTFE
Housing Body Material PC
Housing Classification IP66
Temperature and Relative Humidity Probe
Accurate, Wide
Temp Range
Higher-end sensor where higher
accuracy is required
Overview
Benefits and Features
Detailed Description
Manufacturer's note: In changing temperature conditions
with high humidity, the probe temperature can lag behind
the temperature of surrounding air and this can cause risk of
condensation on the sensor. A wet probe cannot observe
the actual humidity in the ambient air. If the condense water
is contaminated, the life span of the probe may shorten and
the calibration may change.
Mounts to a mast, crossarm, or user-supplied pole
Compatible with most Campbell Scientific data loggers
connected to the datalogger’s switched 12 V terminal.
Dataloggers that do not have a switched 12 V terminal, such
as the CR510 or CR7, can use the SW12V switched 12 V
device to switch power to the sensor only during
measurement.
Specifications
Voltage Output 0 to 1 Vdc
Average Current
Consumption
Operating Voltage 7 to 28 Vdc
Settling Time 2 s (at power up)
For comprehensive details, visit: www.campbellsci.com.au/hmp155a
≤ 3 mA (analog output mode)
Field-Replaceable Chip or
Recalibrate
Recalibrate
Tip Diameter 1.2 cm (0.5 in.)
Length 27.9 cm (11 in.)
Head Height 4 cm (1.6 in.)
Body Height 2.4 cm (0.9 in.)
Body Width 2.0 cm (0.8 in.)
Relative Humidity
Sensing Element HUMICAP 180R
Measurement Range 0 to 100% RH (non-condensing)
Response Time 60 s (90% step change)
20 s (63% step change)
The response time for the RH
specification is for the
HUMICAP 180R at 20°C in still
air with sintered PTFE filter and
a 0 to 75% RH step change.
Factory Calibration
Uncertainty
The factory calibration
uncertainty is defined as ±2
standard deviation limits.
Uncertainty is at +20°C. Small
variations are possible; see
also the calibration certificate.
±1.0% RH 40 to 97% RH
±0.6% RH 0 to 40% RH
Accuracy ± (1.2 + 0.012 × reading) % RH
(at 40° to 60°C)
±1% RH (at 15° to 25°C, 0 to
90% RH)
-NOTE- Accuracy
specifications include nonlinearity, hysteresis, and
repeatability.
±1.7% RH (at 15° to 25°C, 90 to
100% RH)
±(1.0 + 0.008 × reading) % RH
(at -20° to +40°C)
±(1.2 + 0.012 × reading) % RH
(at -40° to -20°C)
±(1.4 + 0.032 × reading) % RH
(at -60° to -40°C)
Air Temperature
Sensing Element PT 100 RTD 1/3 class B IEC 751
Measurement Range -80° to +60°C
Accuracy ±(0.226 - 0.0028 x
temperature)°C (-80° to +20°C)
±(0.055 + 0.0057 x
temperature)°C (+20° to
+60°C)
Entire Temperature Range Refer to graph in probe manual.
For comprehensive details, visit: www.campbellsci.com.au/hmp155a