Campbell Scientific CD294 User Manual

DataView (CD294)
Dual Line Data Display
Revision: 3/08
Copyright © 2002-2008
Campbell Scientific, Inc.

Warranty and Assistance

The DATAVIEW (CD294) DUAL LINE DATA DISPLAY is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.
Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____ 815 West 1800 North Logan, Utah 84321-1784
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
DataView (CD294) Table of Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections.
1. Introduction..................................................................1
2. Installation Procedure.................................................1
3. Software........................................................................1
4. Programming ...............................................................2
5. Mounting in Enclosure Door.......................................7
6. Shipping Kit..................................................................7
7. Hardware ......................................................................7
8. Problems ......................................................................9
A. Custom Programming Cable..................................A-1
Figures
1. Splash Screen..............................................................................................2
2. Open File Window......................................................................................3
3. Open LCD File Window.............................................................................3
4. Existing LCD File Window........................................................................3
5. Information Window ..................................................................................4
6. Main Screen................................................................................................4
7. New Location .............................................................................................4
8. Input Location List .....................................................................................5
9. Completed Screen.......................................................................................5
10. Final Screen..............................................................................................5
11. Communication Options...........................................................................6
12. Waiting for Acknowledge ........................................................................6
13. Incompatible File Type.............................................................................9
14. Unknown File Type................................................................................10
This is a blank page.
i

DataView (CD294) Dual Line Data Display

1. Introduction

The DataView is a two-line, 32-character LCD that displays a real time input location value along with a pre-defined descri pt i on st ri n g an d uni t s st ri n g. Two buttons allow the user to scroll through the programmed locations that are updated as often as they are measured. When the user has not pressed a button in the last two minutes the DataView switches to low power mode, drawing a current of less than 100 μA. The DataView is easily programmed using the Windows based PC294W package.

2. Installation Procedure

1. Using the CD from the CD294 shipping kit, install PC294W on your PC.
2. Connect the gray programming cable’s RJ11 connector into the back of the
CD294 and the other end into your PC’s serial COM por t.
3. Program the CD294 to display input locations as required.
4. Remove the programming cable.
5. Mount the CD294 into your datalogger enclosure.
6. Connect the CD294 data cable to the datalogger’s CS I/O port.
7. Power-up the datalogger and verify correct operation.
8. The CD294 can be reprogrammed at any time if required.

3. Software

COMPUTER SYSTEM REQUIREMENTS
MINIMUM CONFIGURATION
IBM 486 PC/Compatible with 16 MB Ram running Windows 3.x/95.
INSTALLATION
Included in the CD294 shipping kit is a CD containing PC294W. The software can also be downloaded from the CSA web site. The address to collect the file from is:
ftp://campbellsci.com.au/pub/PC294W
Windows 3.1x
1. Insert the PC294 CD into the CD ROM drive.
2. From the Program manager or File manager select ‘Run’ from the File
menu.
3. Type N:\setup (where N is the CD drive).
4. Click OK.
5. Follow the installation instructions as they are presented.
1
DataView (CD294) Dual Line Data Display
Windows 95 / 98/ 2000
1. Insert the PC294 CD into the CD drive.
2. From the Start menu select ‘Run’.
3. Type N:\setup (where N is the CD drive).
4. Click OK.
5. Follow the installation instructions as they are presented.
In either of the above installations, PC294W will create a program group and all the necessary files will be installed. In addition to the program files there will be a sample LCD file called TEST.LCD and a download file called TEST.DLD. These files can be used to modify and send to the DataView.

4. Programming

The DataView is programmed using PC294W, a windows based program which guides the user though the programming process.
The program has the following limitations:
Only the first 255 input locations can be sent to the DataView
The DataView can be configured to display up to 18 locations.
For help on the function of any of the buttons, simply leave the mouse positioned over a button for a short period of time and an extended message will appear.
The program briefly displays a splash screen that displays information about the program, including the License details and the version number.
FIGURE 1. Splash Screen
2
Loading...
+ 12 hidden pages