Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Oil-Lubricated Compressors
Description
This oil-lubricated compressor is designed for do-it-yourselfers with a variety of home and automotive jobs. These compressors can power spray guns, impact wrenches and other tools. Compressed air from this unit will contain moisture. Install a water filter or air dryer if application requires dry air.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates an
imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates a
potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a
potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service. In case of questions, damaged or missing parts,
DO NOT RETURN THE
STOP!
PRODUCT TO THE RETAILER!
Record the Model No., Serial No. and date of purchase located on the base below the pump in the space below.
Model No. ______________________ Serial No. ______________________ Date of purchase ______________________ Retain these numbers for future reference.
please call 1-800-543-6400 for customer assistance. Have the serial number, model number, and parts list (with missing parts circled) before calling.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
You can
dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This dust often contains chemicals known to cause cancer, birth defects, or other reproductive harm. Wear protective gear.
create
Breathable Air Warning
This compressor/pump is not equipped and should not be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor/pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G
7.1 - 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA).
DISCLAIMER OF WARRANTIES In the event the compressor
is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties shall be voided, and the manufacturer disclaims any liability whatsoever for any loss, personal injury or damage.
GENERAL INFORMATION
Do not operate unit
if damaged during shipping, handling or use. Damage may result in bursting and cause injury or property damage.
Do not run
unattended. Leaving compressor in AUTO position may allow it to turn on inadvertently. To prevent this and possible damage from power surge, turn to OFF position after each use.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2010 Campbell Hausfeld/Scott Fetzer
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN634800AV 8/10
Operating Instructions
General Safety Information (Continued)
Since the air compressor and other components (filters, lubricators, hoses, etc.) used, make up a high pressure pumping system, the following safety precautions must be observed at all times:
1. Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
2. Follow all local electrical and safety codes as well as in the US, National Electrical Code (NEC) and Occupational Safety and Health Act (OSHA).
3. Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.
4. Keep visitors away and NEVER allow children in the work area.
5. Wear safety glasses and use hearing protection when operating the pump or unit.
6. Do not stand on or use the pump or unit as a handhold.
7. Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.
8. Check all fasteners at frequent intervals for proper tightness.
Motors,
electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never operate or repair the unit near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.
Com-
pressor parts may be hot even if the unit is stopped.
9. Keep fingers away from
a running compressor; fast moving and hot parts will cause injury and/ or burns.
MANUAL
10. If the equipment should start to abnormally vibrate, STOP the engine/motor and check immediately for the cause. Vibration is generally a warning of trouble.
11. To reduce fire hazard, keep engine/motor exterior free of oil, solvent, or grease.
Never remove or
attempt to adjust safety valve. Keep safety valve free from paint and other accumulations.
Never
attempt to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn or damaged tanks.
Drain liquid from
tank daily.
12. Tanks rust from moisture build-up,
which weakens the tank. Make sure to drain tank daily and inspect periodically for unsafe conditions such as rust formation and corrosion.
13. Fast moving air will stir up dust
and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.
SPRAYING PRECAUTIONS
Do not spray
flammable materials in vicinity of open flame or near ignition sources including the compressor unit.
14. Do not smoke when spraying paint,
insecticides, or other flammable substances.
15. Use a face mask/
respirator when spraying and spray in a well ventilated area to prevent health and fire hazards.
16. Do not direct paint or other sprayed
material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor.
17. When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.
Assembly
HANDLE ASSEMBLY (Figure 1)
Lock Nuts
Washers
Screws
Figure 1 - Handle Assembly
1. Place ends of handle around tank, behind the mounting plate. Align holes in handle to holes in mounting plate.
2. Assemble four (4) screws and washers (from parts package) through holes in mounting plate and handle. Secure with lock nuts.
Never use the
handle to lift the unit completely off the ground. Only use the handle to lift one end so the wheels may be used to move the unit.
WHEEL ASSEMBLY (Figure 2)
Wheel
Nuts
Lock washer
Figure 2 - Wheel Assembly
Wheel assembly kit includes:
- 2 wheels*
- 2 axle bolts*
- 2 lock washers*
- 2 nuts* The items marked with an asterisk (*)
were shipped loose with the unit.
1. Wheel has an offset hub. With offset
hub facing axle iron, assemble axle bolt through holes in wheel and axle iron.
Screws
www.chpower.com
2
HX5100, HX5101
Assembly (Continued)
2. Place lock washer on axle bolt. Then tighten nut securely to threaded part of axle bolt.
3. Repeat procedure with other side.
LUBRICATION
THIS UNIT IS
SHIPPED WITHOUT OIL IN PUMP! Follow lubrication instructions before operating compressor.
Use oil shipped with the compressor. Do not use regular automotive oil such as 10W-30. Additives in regular motor
oil can cause valve deposits and reduce pump life. For maximum pump life, drain and replace oil after the first few hours of run time.
The compressor pump takes approximately 280 ml (9.5 ozs.) of oil. The sight glass, located on the crankcase portion of the pump, is marked with “max” and “min” levels. Avoid overfilling by adding oil gradually and checking the oil level with the sight glass several times. Add enough oil to reach the “max” level on the sight glass. Proper oil level is illustrated in Figure 3.
Max.
Min.
Figure 3 - Proper oil level
Side view of unit
Intake filter
Oil fill / breather
INTAKE FILTER
Thread the intake air filter into the threaded opening in the side of the compressor head as illustrated in Figure
4. Tighten gently with a wrench.
Figure 4 - Intake filter installation
Installation
LOCATION
It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.
A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.
Do not locate the
compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor.
Top view of unit
Exhaust Tube
Pressure Switch (Auto/Off)
ELECTRICAL INSTALLATION
All wiring and
electrical connections should be performed by a qualified electrician. Installation must be in accordance with local codes and national electrical codes.
WIRING
1. Local electrical wiring codes differ
from area to area. Source wiring, plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this minimum.
2. Use a slow blow fuse or a circuit
breaker.
3. Make sure the product is connected
to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Overheating, short
circuiting and fire damage will result from inadequate wiring.
Sight
glass
Handle
Oil drain plug
Drain valve
Figure 6 - Unit Identification
Check Valve
Regulator
Safety Valve
Extension cords
Length of Cord (ft) 25 50 100
Gauge of Cord 14 12 10
www.chpower.com
3
Operating Instructions
Operation
•  Pressure Switch - Auto/Off Switch (Figure 7) - In the AUTO position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure. In the OFF position, the compressor will not operate. This switch should be in the OFF position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools.
Figure 7 - Auto/Off Switch
•  Regulator - The regulator controls the amount of air pressure released at the hose outlet.
•  ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
•  Exhaust Tube - This tube carries compressed air from the pump to the check valve. This tube becomes very hot during use. To avoid the risk of severe burns, never touch the exhaust tube.
•  Check Valve - A one-way valve that allows air to enter the tank, but prevents air in the tank from flowing back into the compressor pump.
•  Handle - Designed to move the compressor.
Never use the
handle on wheeled units to lift the unit completely off the ground.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture.
•  Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture from tank by opening the drain valve located underneath the tank.
BEFORE FIRST START-UP BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise (to the right) to open air flow.
2. Turn on/off switch to OFF position.
3. Plug in power cord.
4. Turn on/off switch to AUTO position and run compressor for 30 minutes.
5. Turn on/off switch to OFF position.
6. Unplug power cord- open drain valve.
The compressor is now ready for use.
BEFORE FIRST START-UP OPERATING PROCEDURE
1. Turn regulator knob fully counter clockwise (to the left) to close air flow.
2. Connect air hose to outlet of regulator.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to AUTO position and let compressor run until it reaches automatic shutoff pressure.
6. Attach tire chuck or tool to end of hose.
7. Turn regulator knob clockwise (to the right) to desired pressure of tool being used.
On/Off cycling of compressor
In the AUTO position, the compressor pumps air into the tank. When a shutoff (preset “cut-out”) pressure is reached, the compressor automatically shuts off.
If the compressor is left in the AUTO position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically.
In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord from
electrical outlet.
ASME SAFETY VALVE
Do not remove or
attempt to adjust
the safety valve!
Check the safety valve by performing the following steps:
1. Plug the compressor in and run until shut off pressure is reached (see Operating Procedure).
2. Wearing safety glasses, pull the ring on the safety valve (see Figures 6 and 8) to release pressure from compressor tank. Use your other hand to deflect fast-moving air from being directed toward your face.
Figure 8
www.chpower.com
4
HX5100, HX5101
Operation (Continued)
3. The safety valve should automatically close at approximately 40 psi - 50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced.
Safety valve must
be replaced if it cannot be actuated or it leaks air after ring is released.
PRESSURE GAUGES
Gauge attached to regulator indicates air pressure going to hose (and any tool attached to end of hose). Gauge attached to pressure switch indicates air pressure in tank.
Maintenance
Disconnect power source and then release all pressure from the system before attempting to install, service, relocate or perform any maintenance.
Check compressor often for any visible problems and follow maintenance procedures each time compressor is used.
1. Turn compressor off and release
pressure from system. To release pressure from system, pull ring on ASME safety valve (see Figures 6 and
8). Deflect escaping air by shielding valve with one hand as you pull ring with other hand. Pull ring until tank is empty.
A large amount of
fast moving air will be released when the safety valve is opened with pressure in the tank. Wear ANSI approved Z87.1 safety glasses.
2. Drain moisture from tank by
opening drain valve (see Figure
6) underneath tank. Tilt tank to remove all moisture.
3. Clean dust and dirt from tank,
air lines and pump cover while compressor is still OFF.
OIL CHANGE
1. Allow compressor to run and warm
up oil. Unplug unit.
2. Position a pan under pump end of unit.
3. Remove oil drain plug (see Figure 6). Allow oil to collect in pan. Tilt unit to completely drain.
4. Replace drain plug, fill pump to full line on sight glass. Use Chevron synthetic 5W-30, Mobil 1 5W-30 or 10W-30 synthetic motor oil. Using other types of oil will cause starting problems.
Max.
Min.
Figure 9 - Proper oil level
5. Change oil after every 50 hours of use.
INTAKE AIR FILTER MAINTENANCE
Removal, Inspection and Replacement (Figure 10)
Filter element
Filter cover
Figure 10 - Intake filter maintenance
The intake filter element should be removed and checked periodically. A clogged intake filter can decrease compressor performance and cause the compressor to overheat.
1. Rotate the filter cover counter clockwise and remove .
2. Remove the filter element and inspect.
3. If the filter element is dirty or clogged, replace it.
4. Reinstall filter and cover.
IMPORTANT: Locate unit as far from spraying area as hose will allow to prevent overspray from clogging filter.
OVERLOAD PROTECTOR SECTION
This compressor is
equipped with an automatic reset overload protector which will shut off motor if it becomes overloaded.
If overload protector shuts motor OFF frequently, look for the following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
If the overload
protector is actuated, the motor must be allowed to cool down for 30 minutes before it will reset.
STORAGE
1. Drain tank of moisture.
2. When not in use, store compressor in
a cool, dry place.
3. Disconnect hose and hang open
ends down to allow any moisture to drain.
www.chpower.com
5
Operating Instructions
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Compressor will not run 1. Switch in OFF position
2. No electrical power at wall outlet
3. Compressor has reached automatic shutoff pressure
4. Motor overloaded
5. Pressure switch bad
Motor hums but cannot run or runs slowly
Flow blows/circuit breaker trips repeatedly
Thermal overload protector cuts out repeatedly
Knocks, rattles, and/or excessive vibration
Tank pressure drops when compressor shuts off
1. Defective check valve
2. Defective unloader valve (on pressure switch)
3. Low voltage
4. Loose electrical connections
5. Wrong gauge wire or length of extension cord
6. Defective motor capacitor
7. Shorted or open motor winding
1. Incorrect fuse size, circuit overloaded
2. Wrong gauge wire or length of extension cord
3. Defective check valve
4. Defective unloader valve (on pressure switch)
5. Defective motor capacitor
6. Motor shorted or seized
1. Low voltage
2. Wrong gauge wire or length of extension cord
3. Clogged intake filter
4. Lack of proper ventilation/room temperature too high
5. Defective check valve
6. Defective unloader valve (on pressure switch)
7. Compressor valves failed
1. Loose mounting bolts
2. Tank not level
3. Cylinder or piston is worn/scored
1. Loose drain valve
2. Check valve leaking
3. Loose connections at fittings, tubing, etc.
1. Make sure compressor is plugged in and switch is ON.
2. Check circuit breaker or fuse at electrical panel.
3. Release air from tank until compressor restarts automatically.
4. Allow compressor to cool for approximately 30 minutes. Make sure compressor is run in a clean, well-ventilated area.
5. Replace pressure switch.
1. Repair or replace.
2. Repair or replace.
3. Check voltage at wall outlet with voltmeter.
4. Check all electrical connections.
5. Check extension cord chart for proper extension cord usage.
6. Replace capacitor.
7. Replace motor assembly.
Do not disassemble
tank; bleed tank
1. Check for proper fuse. Use time delay fuse. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit.
2. Check extension cord chart for proper extension cord usage.
3. Repair or replace.
4. Repair or replace.
5. Replace capacitor.
6. Replace motor assembly.
Do not disassemble
tank; bleed tank
1. Check voltage at wall outlet with voltmeter.
2. Check extension cord chart for proper extension cord usage.
3. Clean or replace filter.
4. Move compressor to well-ventilated area.
5. Repair or replace.
6. Repair or replace.
7. Replace valve assembly
Do not disassemble
tank; bleed tank
1. Tighten bolts.
2. Use sturdy wedge/object to bring tank to level position.
3. Replace or repair as necessary.
1. Tighten.
2. Remove check valve. Clean or replace.
3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble.
check valve with air in
check valve with air in
check valve with air in
www.chpower.com
6
Troubleshooting Chart (Continued)
Symptom Possible Cause(s) Corrective Action
4. Tank leaks 4. Check tank for leaks with soap and water solution. If leak is detected, tank must be replaced with genuine replacement part.
Do not disassemble
bleed tank
Compressor runs continuously and air output is lower than normal/low discharge pressure
Excessive moisture in discharge air
Compressor runs continuously and safety valve opens as pressure rises
Excessive starting and stopping (auto start)
Air leaking from unloader valve on pressure switch
1. Excessive air usage, compressor too small
2. Clogged intake filter
3. Loose connections at fittings, tubing, etc.
4. Tank leaks
5. Broken valves
6. Piston ring worn
1. Excessive water in tank
2. High humidity
1. Defective pressure switch
2. Defective safety valve
1. Excessive condensation in tank
2. Loose connections at fittings, tubing, etc.
3. Tank leaks
1. Check valve stuck in an open position
2. Unloader valve stuck in open position
1. Decrease usage or purchase unit with higher air delivery (SCFM).
2. Clean or replace.
3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble.
4. Check tank for leaks with soap and water solution. If leak is detected, tank must be replaced with genuine replacement part.
5. Replace compressor valves as necessary.
6. Replace piston and cylinder.
1. Drain tank.
2. Move to area of less humidity; use air line filter.
NOTE: Water condensation is not caused by
compressor malfunction.
1. Replace switch.
2. Replace safety valve with genuine replacement part.
1. Drain more often.
2. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble.
3. Check tank for leaks with soap and water solution. If leak is detected, tank must be replaced with genuine replacement part.
Do not disassemble
bleed tank
1. Repair or replace check valve.
2. Repair or replace unloader valve.
Do not disassemble
bleed tank
HX5100, HX5101
check valve with air in tank;
check valve with air in tank;
check valve with air in tank;
www.chpower.com
7
Operating Instructions
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
4. WHAT PRODUCT IS COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions noted below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM
THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT,
FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with
instructions provided in the owner’s manual(s) supplied with compressor. D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment. E. Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc. F. Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must
comply with the warranty given by the engine manufacturer which is supplied with the product. G. Additional items not covered under this warranty:
1. All Compressors a. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in
accordance with installation and operation guidelines or damaged by contact with tools or surroundings. b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants. c. Cosmetic defects that do not interfere with compressor functionality. d. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments. e. Electric motors, check valves and pressure switches. f. Drain cocks. g. Damage due to incorrect voltage or improper wiring. h. Other items not listed but considered general wear parts. i. Pressure switches, air governors and safety valves modified from factory settings.
2. Lubricated Compressors a. Pump wear or valve damage caused by using oil not specified. b. Pump wear or valve damage caused by any oil contamination or by failure to follow proper oil maintenance
guidelines.
3. Belt Drive / Direct Drive / Gas Driven Compressors a. Belts. b. Ring wear or valve damage from inadequate filter maintenance. c. Manually adjusted load/unload and throttle control devices.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service
Center. Freight costs, if any, must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from State to State or country to country.
www.chpower.com
8
Loading...
+ 16 hidden pages