See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions HX5100, HX5101
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Oil-Lubricated
Compressors
Description
This oil-lubricated compressor is
designed for do-it-yourselfers with a
variety of home and automotive jobs.
These compressors can power spray
guns, impact wrenches and other tools.
Compressed air from this unit will
contain moisture. Install a water filter
or air dryer if application requires dry
air.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates an
imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
DO NOT RETURN THE
STOP!
PRODUCT TO THE
RETAILER!
Record the Model No., Serial No. and date
of purchase located on the base below the
pump in the space below.
Model No. ______________________
Serial No. ______________________
Date of purchase ______________________
Retain these numbers for future reference.
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
You can
dust when you cut, sand, drill
or grind materials such as
wood, paint, metal, concrete,
cement, or other masonry. This dust
often contains chemicals known to
cause cancer, birth defects, or other
reproductive harm. Wear protective
gear.
create
Breathable Air Warning
This compressor/pump is not
equipped and should not be
used “as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G
DISCLAIMER OF WARRANTIES
In the event the compressor
is used for the purpose of
breathing air application
and proper in-line safety
and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
the manufacturer disclaims any
liability whatsoever for any loss,
personal injury or damage.
GENERAL INFORMATION
Do not operate unit
if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
Do not run
unattended.
Leaving compressor in AUTO position
may allow it to turn on inadvertently.
To prevent this and possible damage
from power surge, turn to OFF position
after each use.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN634800AV 8/10
Operating Instructions
General Safety Information
(Continued)
Since the air compressor and other
components (filters, lubricators, hoses,
etc.) used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals included
with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.
2. Follow all local electrical and
safety codes as well as in the US,
National Electrical Code (NEC) and
Occupational Safety and Health Act
(OSHA).
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses and
use hearing protection
when operating the pump
or unit.
6. Do not stand on or use the pump or
unit as a handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
Motors,
electrical
equipment and controls can
cause electrical arcs that will
ignite a flammable gas or
vapor. Never operate or repair the unit
near a flammable gas or vapor. Never
store flammable liquids or gases in the
vicinity of the compressor.
Com-
pressor
parts may be hot even if the
unit is stopped.
9. Keep fingers away from
a running compressor; fast moving
and hot parts will cause injury and/
or burns.
MANUAL
10. If the equipment should start
to abnormally vibrate, STOP
the engine/motor and check
immediately for the cause. Vibration
is generally a warning of trouble.
11. To reduce fire hazard,
keep engine/motor
exterior free of oil,
solvent, or grease.
Never remove or
attempt to adjust
safety valve. Keep safety valve free
from paint and other accumulations.
Never
attempt
to repair or modify a tank!
Welding, drilling or any other
modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn or
damaged tanks.
Drain liquid from
tank daily.
12. Tanks rust from moisture build-up,
which weakens the tank. Make
sure to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and corrosion.
13. Fast moving air will stir up dust
and debris which may be harmful.
Release air slowly when draining
moisture or depressurizing the
compressor system.
SPRAYING PRECAUTIONS
Do not spray
flammable
materials in vicinity of open flame or
near ignition sources including the
compressor unit.
14. Do not smoke when spraying paint,
insecticides, or other flammable
substances.
15. Use a face mask/
respirator when spraying
and spray in a well
ventilated area to prevent
health and fire hazards.
16. Do not direct paint or other sprayed
material at the compressor. Locate
compressor as far away from
the spraying area as possible to
minimize overspray accumulation on
the compressor.
17. When spraying or cleaning with
solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.
Assembly
HANDLE ASSEMBLY (Figure 1)
Lock Nuts
Washers
Screws
Figure 1 - Handle Assembly
1. Place ends of handle around tank,
behind the mounting plate. Align
holes in handle to holes in mounting
plate.
2. Assemble four (4) screws and
washers (from parts package)
through holes in mounting plate
and handle. Secure with lock nuts.
Never use the
handle to lift the
unit completely off the ground. Only
use the handle to lift one end so the
wheels may be used to move the unit.
WHEEL ASSEMBLY (Figure 2)
Wheel
Nuts
Lock washer
Figure 2 - Wheel Assembly
Wheel assembly kit includes:
- 2 wheels*
- 2 axle bolts*
- 2 lock washers*
- 2 nuts*
The items marked with an asterisk (*)
were shipped loose with the unit.
1. Wheel has an offset hub. With offset
hub facing axle iron, assemble axle
bolt through holes in wheel and axle
iron.
Screws
www.chpower.com
2
HX5100, HX5101
Assembly (Continued)
2. Place lock washer on axle bolt. Then
tighten nut securely to threaded
part of axle bolt.
3. Repeat procedure with other side.
LUBRICATION
THIS UNIT IS
SHIPPED WITHOUT
OIL IN PUMP! Follow lubrication
instructions before operating
compressor.
Use oil shipped with the compressor. Do
not use regular automotive oil such
as 10W-30. Additives in regular motor
oil can cause valve deposits and reduce
pump life. For maximum pump life,
drain and replace oil after the first few
hours of run time.
The compressor pump takes
approximately 280 ml (9.5 ozs.) of oil.
The sight glass, located on the crankcase
portion of the pump, is marked
with “max” and “min” levels. Avoid
overfilling by adding oil gradually and
checking the oil level with the sight
glass several times. Add enough oil to
reach the “max” level on the sight glass.
Proper oil level is illustrated in Figure 3.
Max.
Min.
Figure 3 - Proper oil level
Side view of unit
Intake filter
Oil fill / breather
INTAKE FILTER
Thread the intake air filter into the
threaded opening in the side of the
compressor head as illustrated in Figure
4. Tighten gently with a wrench.
Figure 4 - Intake filter installation
Installation
LOCATION
It is extremely important to install the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than
100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.
Do not locate the
compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination.
This debris will damage the motor.
Top view of unit
Exhaust
Tube
Pressure Switch
(Auto/Off)
ELECTRICAL INSTALLATION
All wiring and
electrical
connections should be performed by a
qualified electrician. Installation must
be in accordance with local codes and
national electrical codes.
WIRING
1. Local electrical wiring codes differ
from area to area. Source wiring,
plug and protector must be rated for
at least the amperage and voltage
indicated on motor nameplate, and
meet all electrical codes for this
minimum.
2. Use a slow blow fuse or a circuit
breaker.
3. Make sure the product is connected
to an outlet having the same
configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire
for electric current. This product
is equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be
plugged into an outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring.
Sight
glass
Handle
Oil drain plug
Drain valve
Figure 6 - Unit Identification
Check
Valve
Regulator
Safety
Valve
Extension cords
Length of Cord (ft)2550100
Gauge of Cord141210
www.chpower.com
3
Operating Instructions
Operation
• Pressure Switch - Auto/Off Switch
(Figure 7) - In the AUTO position, the
compressor shuts off automatically
when tank pressure reaches the
maximum preset pressure. In the
OFF position, the compressor will
not operate. This switch should be in
the OFF position when connecting
or disconnecting the power cord
from the electrical outlet or when
changing air tools.
Figure 7 - Auto/Off Switch
• Regulator - The regulator controls
the amount of air pressure released
at the hose outlet.
• ASME Safety Valve - This valve
automatically releases air if the
tank pressure exceeds the preset
maximum.
• Exhaust Tube - This tube carries
compressed air from the pump to
the check valve. This tube becomes
very hot during use. To avoid the
risk of severe burns, never touch the
exhaust tube.
• Check Valve - A one-way valve
that allows air to enter the tank,
but prevents air in the tank from
flowing back into the compressor
pump.
• Handle - Designed to move the
compressor.
Never use the
handle on wheeled
units to lift the unit completely off the
ground.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the tank. When
using a paint spray or sandblast gun, this water will be carried from the tank
through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially
when spraying other than water based paints. If sandblasting, it will cause
the sand to cake and clog the gun, rendering it ineffective. A filter in the air
line (MP3105), located as near to the gun as possible, will help eliminate this
moisture.
• Drain Valve - This valve is located
on the bottom of the tank. Use
this valve to drain moisture from
the tank daily to reduce the risk of
corrosion.
Reduce tank pressure below 10 psi, then
drain moisture from tank daily to avoid
tank corrosion. Drain moisture from
tank by opening the drain valve located
underneath the tank.
BEFORE FIRST START-UP
BREAK-IN PROCEDURE
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise
(to the right) to open air flow.
2. Turn on/off switch to OFF position.
3. Plug in power cord.
4. Turn on/off switch to AUTO position
and run compressor for 30 minutes.
5. Turn on/off switch to OFF position.
6. Unplug power cord- open drain
valve.
The compressor is now ready for use.
BEFORE FIRST START-UP
OPERATING PROCEDURE
1. Turn regulator knob fully counter
clockwise (to the left) to close air
flow.
2. Connect air hose to outlet of
regulator.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to AUTO position
and let compressor run until it
reaches automatic shutoff pressure.
6. Attach tire chuck or tool to end of
hose.
7. Turn regulator knob clockwise (to
the right) to desired pressure of tool
being used.
On/Off cycling of compressor
In the AUTO position, the compressor
pumps air into the tank. When a shutoff
(preset “cut-out”) pressure is reached,
the compressor automatically shuts off.
If the compressor is left in the AUTO
position and air is depleted from
the tank by use of a tire chuck, tool,
etc., the compressor will restart
automatically at its preset “cut-in”
pressure. When a tool is being used
continuously, the compressor will cycle
on and off automatically.
In the OFF position, the pressure switch
cannot function and the compressor
will not operate. Make sure switch
is in OFF position when connecting
or disconnecting power cord from
electrical outlet.
ASME SAFETY VALVE
Do not remove or
attempt to adjust
the safety valve!
Check the safety valve by performing
the following steps:
1. Plug the compressor in and run until
shut off pressure is reached (see
Operating Procedure).
2. Wearing safety glasses, pull the
ring on the safety valve (see Figures
6 and 8) to release pressure from
compressor tank. Use your other
hand to deflect fast-moving air from
being directed toward your face.
Figure 8
www.chpower.com
4
HX5100, HX5101
Operation (Continued)
3. The safety valve should
automatically close at approximately
40 psi - 50 psi. If the safety valve
does not allow air to be released
when you pull on the ring, or if
it does not close automatically, it
MUST be replaced.
Safety valve must
be replaced if it
cannot be actuated or it leaks air after
ring is released.
PRESSURE GAUGES
Gauge attached to regulator indicates
air pressure going to hose (and any
tool attached to end of hose). Gauge
attached to pressure switch indicates air
pressure in tank.
Maintenance
Disconnect power source and
then release all pressure from
the system before attempting
to install, service, relocate or perform
any maintenance.
Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.
1. Turn compressor off and release
pressure from system. To release
pressure from system, pull ring on
ASME safety valve (see Figures 6 and
8). Deflect escaping air by shielding
valve with one hand as you pull ring
with other hand. Pull ring until tank
is empty.
A large amount of
fast moving air will
be released when the safety valve is
opened with pressure in the tank. Wear
ANSI approved Z87.1 safety glasses.
2. Drain moisture from tank by
opening drain valve (see Figure
6) underneath tank. Tilt tank to
remove all moisture.
3. Clean dust and dirt from tank,
air lines and pump cover while
compressor is still OFF.
OIL CHANGE
1. Allow compressor to run and warm
up oil. Unplug unit.
2. Position a pan under pump end of
unit.
3. Remove oil drain plug (see Figure 6).
Allow oil to collect in pan. Tilt unit
to completely drain.
4. Replace drain plug, fill pump to
full line on sight glass. Use Chevron
synthetic 5W-30, Mobil 1 5W-30 or
10W-30 synthetic motor oil. Using
other types of oil will cause starting
problems.
Max.
Min.
Figure 9 - Proper oil level
5. Change oil after every 50 hours of
use.
INTAKE AIR FILTER MAINTENANCE
Removal, Inspection and Replacement
(Figure 10)
Filter element
Filter cover
Figure 10 - Intake filter maintenance
The intake filter element should be
removed and checked periodically.
A clogged intake filter can decrease
compressor performance and cause the
compressor to overheat.
1. Rotate the filter cover counter
clockwise and remove .
2. Remove the filter element and
inspect.
3. If the filter element is dirty or
clogged, replace it.
4. Reinstall filter and cover.
IMPORTANT: Locate unit as far from
spraying area as hose will allow to
prevent overspray from clogging filter.
OVERLOAD PROTECTOR SECTION
This compressor is
equipped with an
automatic reset overload protector
which will shut off motor if it becomes
overloaded.
If overload protector shuts motor OFF
frequently, look for the following
causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
If the overload
protector is
actuated, the motor must be allowed to
cool down for 30 minutes before it will
reset.
STORAGE
1. Drain tank of moisture.
2. When not in use, store compressor in
a cool, dry place.
3. Disconnect hose and hang open
ends down to allow any moisture to
drain.
www.chpower.com
5
Operating Instructions
Troubleshooting Chart
SymptomPossible Cause(s)Corrective Action
Compressor will not run1. Switch in OFF position
2. No electrical power at wall outlet
3. Compressor has reached automatic shutoff
pressure
4. Motor overloaded
5. Pressure switch bad
Motor hums but cannot run or
runs slowly
Flow blows/circuit breaker trips
repeatedly
Thermal overload protector
cuts out repeatedly
Knocks, rattles, and/or excessive
vibration
Tank pressure drops when
compressor shuts off
1. Defective check valve
2. Defective unloader valve (on pressure switch)
3. Low voltage
4. Loose electrical connections
5. Wrong gauge wire or length of extension cord
6. Defective motor capacitor
7. Shorted or open motor winding
1. Incorrect fuse size, circuit overloaded
2. Wrong gauge wire or length of extension cord
3. Defective check valve
4. Defective unloader valve (on pressure switch)
5. Defective motor capacitor
6. Motor shorted or seized
1. Low voltage
2. Wrong gauge wire or length of extension cord
3. Clogged intake filter
4. Lack of proper ventilation/room temperature
too high
5. Defective check valve
6. Defective unloader valve (on pressure switch)
7. Compressor valves failed
1. Loose mounting bolts
2. Tank not level
3. Cylinder or piston is worn/scored
1. Loose drain valve
2. Check valve leaking
3. Loose connections at fittings, tubing, etc.
1. Make sure compressor is plugged in and switch
is ON.
2. Check circuit breaker or fuse at electrical panel.
3. Release air from tank until compressor restarts
automatically.
4. Allow compressor to cool for approximately 30
minutes. Make sure compressor is run in a clean,
well-ventilated area.
5. Replace pressure switch.
1. Repair or replace.
2. Repair or replace.
3. Check voltage at wall outlet with voltmeter.
4. Check all electrical connections.
5. Check extension cord chart for proper extension
cord usage.
6. Replace capacitor.
7. Replace motor assembly.
Do not disassemble
tank; bleed tank
1. Check for proper fuse. Use time delay fuse.
Disconnect other electrical appliances from
circuit or operate compressor on its own branch
circuit.
2. Check extension cord chart for proper extension
cord usage.
3. Repair or replace.
4. Repair or replace.
5. Replace capacitor.
6. Replace motor assembly.
Do not disassemble
tank; bleed tank
1. Check voltage at wall outlet with voltmeter.
2. Check extension cord chart for proper extension
cord usage.
3. Clean or replace filter.
4. Move compressor to well-ventilated area.
5. Repair or replace.
6. Repair or replace.
7. Replace valve assembly
Do not disassemble
tank; bleed tank
1. Tighten bolts.
2. Use sturdy wedge/object to bring tank to level
position.
3. Replace or repair as necessary.
1. Tighten.
2. Remove check valve. Clean or replace.
3. Check all connections with soap and water
solution. If a leak is detected, (1) tighten or (2)
remove fitting and apply pipe tape to threads
and reassemble.
check valve with air in
check valve with air in
check valve with air in
www.chpower.com
6
Troubleshooting Chart (Continued)
SymptomPossible Cause(s)Corrective Action
4. Tank leaks4. Check tank for leaks with soap and water solution.
If leak is detected, tank must be replaced with
genuine replacement part.
Do not disassemble
bleed tank
Compressor runs continuously
and air output is lower than
normal/low discharge pressure
Excessive moisture in discharge
air
Compressor runs continuously
and safety valve opens as
pressure rises
Excessive starting and stopping
(auto start)
Air leaking from unloader valve
on pressure switch
1. Excessive air usage, compressor too small
2. Clogged intake filter
3. Loose connections at fittings, tubing, etc.
4. Tank leaks
5. Broken valves
6. Piston ring worn
1. Excessive water in tank
2. High humidity
1. Defective pressure switch
2. Defective safety valve
1. Excessive condensation in tank
2. Loose connections at fittings, tubing, etc.
3. Tank leaks
1. Check valve stuck in an open position
2. Unloader valve stuck in open position
1. Decrease usage or purchase unit with higher air
delivery (SCFM).
2. Clean or replace.
3. Check all connections with soap and water solution.
If a leak is detected, (1) tighten or (2) remove fitting
and apply pipe tape to threads and reassemble.
4. Check tank for leaks with soap and water solution.
If leak is detected, tank must be replaced with
genuine replacement part.
5. Replace compressor valves as necessary.
6. Replace piston and cylinder.
1. Drain tank.
2. Move to area of less humidity; use air line filter.
NOTE: Water condensation is not caused by
compressor malfunction.
1. Replace switch.
2. Replace safety valve with genuine replacement
part.
1. Drain more often.
2. Check all connections with soap and water solution.
If a leak is detected, (1) tighten or (2) remove fitting
and apply pipe tape to threads and reassemble.
3. Check tank for leaks with soap and water solution.
If leak is detected, tank must be replaced with
genuine replacement part.
Do not disassemble
bleed tank
1. Repair or replace check valve.
2. Repair or replace unloader valve.
Do not disassemble
bleed tank
HX5100, HX5101
check valve with air in tank;
check valve with air in tank;
check valve with air in tank;
www.chpower.com
7
Operating Instructions
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR):
Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell
Hausfeld compressor.
4. WHAT PRODUCT IS COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions
noted below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM
THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial
or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow
limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT,
FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or
limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with
instructions provided in the owner’s manual(s) supplied with compressor.
D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E. Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F. Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must
comply with the warranty given by the engine manufacturer which is supplied with the product.
G. Additional items not covered under this warranty:
1. All Compressors
a. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in
accordance with installation and operation guidelines or damaged by contact with tools or surroundings.
b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
c. Cosmetic defects that do not interfere with compressor functionality.
d. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
e. Electric motors, check valves and pressure switches.
f. Drain cocks.
g. Damage due to incorrect voltage or improper wiring.
h. Other items not listed but considered general wear parts.
i. Pressure switches, air governors and safety valves modified from factory settings.
2. Lubricated Compressors
a. Pump wear or valve damage caused by using oil not specified.
b. Pump wear or valve damage caused by any oil contamination or by failure to follow proper oil maintenance
guidelines.
3. Belt Drive / Direct Drive / Gas Driven Compressors
a. Belts.
b. Ring wear or valve damage from inadequate filter maintenance.
c. Manually adjusted load/unload and throttle control devices.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or
component which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty
period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records.
B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service
Center. Freight costs, if any, must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be
scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of
replacement parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other
rights which vary from State to State or country to country.
www.chpower.com
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.