Campbell Hausfeld KTV008, FHV009 User Manual

Notes Notas
Operating Instructions Instructions d’Utilisation Instrucciones de Funcionamiento
weaken the tank resulting in damage from rupture or explosion. Always replace worn, damaged or cracked tanks.
• Release air pressure from air tank by pulling safety relief ring before servicing or replacing parts.
Wear ANSI Z87.1-approved safety glasses during operation to avoid eye injury.
• For dry air only. Do not use to store
or disperse liquids or flammable gases.
• Store inside. Do not store outside or
in direct sunlight.
• Only use attachments rated at 150
psi minimum.
• Check air hoses for weak or worn
condition before each use. Make sure all connections are secure.
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
Portable air tanks are high quality, welded steel pressure vessels designed to carry a supply of compressed air for home, farm and automobile uses.
This tank does not
have ASME certification. Before using, check local and state code requirements.
Unpacking
When unpacking, inspect carefully for any damage that may have occurred during transit. Make sure any loose fittings, bolts, etc., are tightened before putting unit into service.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a
potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
Operating Instructions Models KTV008 and FHV009
IN287000AV 6/04
General Safety Information
The following safety precautions must be observed at all times:
Risk of explosion.
Failure to follow warnings and instructions could cause death or severe injury.
• Read all manuals
included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment. Follow all instructions.
• Only persons well acquainted with
these rules of safe operation should be allowed to use the unit.
Never fill the tank
above 125 psi. Personal injury or property damage could occur.
Never fill from bottled gas or any
air system which produces over 150 psi.
• Do not alter or tamper with the
safety relief valve. In the event that the safety relief valve is tampered with, existing warranties shall be voided and Campbell Hausfeld disclaims any liability whatsoever for any loss, personal injury or damage.
• This tank is stamped with a
“DISCARD AFTER” date located on the handle. Discard tank and do NOT use after this date has passed. Replace with new tank.
NEVER
attempt to repair or modify a tank. Welding, drilling or any other modification will
Air Carry Tank
© 2004 Campbell Hausfeld/Scott Fetzer
Breathable Air Warning
This tank is not equipped and should not be used to supply breathing quality air.
For parts, product & service information
visit www.chpower.com
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
See Warranty on page 5 for important information about commercial use of this product.
DISCLAIMER OF WARRANTIES In the event the tank is used for the purpose of breathing air application, existing warranties shall be voided, and Campbell Hausfeld disclaims any liability whatsoever for any loss, personal injury or damage.
NOTICE
!
DANGER
!
WARNING
!
CAUTION
NOTICE
BUILT TO LAST
!
DANGER
!
DANGER
!
DANGER
!
DANGER
MANUAL
!
DANGER
!
WARNING
Instrucciones de Funcionamiento
15 Sp
General Safety Information (Cont.)
Use only genuine
Campbell Hausfeld replacement parts and accessories when servicing unit. Failure to do so could result in death or serious injury.
Assembly
The air hose is supplied loose to prevent damage during transit. Use 9/16” open end wrench to attach thread-sealed 1/4” NPT male hose end to air outlet on manifold (opposite filler valve). Tighten just to finger tight then turn 2-3 more times.
Operation
• Pull safety relief valve before filling
to be sure the valve moves freely.
1. Take portable tank to a source of
clean, dry, compressed air (ie. full service gas station, truck stop etc. Some modern convenience stations do not have sufficient pressure to fill the tank). The recommended fill pressure is between 85 and 125 psi.
2. Press chuck from air source onto
filler valve located on the side of the brass manifold (See Figure 1). Fill tank to a maximum of 125 psi as indicated on pressure gauge. The safety relief valve is preset to 135 psi to prevent overfilling.
Do not rely on
safety relief valve to indicate when tank is full.
!
2
Operating Instructions
NOTE: The air shut-off valve (red knob) does not have to be opened to fill the tank.
3. Inflate object by locking universal adapter onto valve stem. Be sure to press universal adapter down over valve stem threads completely. When universal adapter is firmly in place, press locking lever down to lock onto valve stem (see Figure 2).
NOTE: The universal adapter does not have a valve. The air flow is controlled by the air shutoff valve on the manifold.
4. Open air shut-off valve by turning counterclockwise to allow air to flow into hose.
The tank manifold
gauge does not indicate the pressure in the object being filled. Use a separate gauge to check the object.
5. Turn the air shut-off valve clockwise
to the closed position before unlocking universal adapter from valve stem to prevent air leaks from the hose. Do not over tighten.
Maintenance
Accumulated
moisture must be drained from tank regularly to prevent rusting. Failure to do so will weaken the tank and may result in injury or property damage due to tank bursting or rupture.
Draining Instructions:
1. Release pressure from tank by opening air shutoff valve or pulling ring on safety valve.
2. Fully open drain valve on bottom of tank by turning it counterclockwise.
3. Allow all moisture in tank to drain.
4. Close drain valve by turning it clockwise. Do not overtighten.
Technical Service
For information regarding the operation of the product, please call 1-800-543-6400.
Figure 2
Universal Adapter
Lock
Valve Stem
Figure 1
Pressure Gauge Manifold
Air Shutoff
Safety Relief Valve
Filler Valve
www.chpower.com
Garantía Limitada
1 DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un año
2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400
3. QUIEN RECIBE ESTA GARANTIA (EL COMPRADOR): El comprador original (que no sea un revendedor) del producto Campbell Hausfeld.
4. PRODUCTOS CUBIERTOS POR ESTA GARANTIA: Cualquier clavadora, grapadora, herramienta neumática, pistola pulverizadora, inflador o accesorio neumático suministrado o fabricado por el Garante.
5. COBERTURA DE LA GARANTIA: Los defectos substanciales de material y fabricación que ocurran dentro del período de validez de la garantía.
6. LO QUE NO ESTA CUBIERTO POR ESTA GARANTIA: A. Las garantías implícitas, incluyendo aquellas de comercialidad E IDONEIDAD PARA FINES PARTICULARES, ESTAN
LIMITADOS A LO ESPECIFICADO EN EL PARRAFO DE DURACION. Si este producto es empleado para uso comercial, industrial o para renta, la garantía será aplicable por noventa (90) días a partir de la fecha de compra. En algunos estados no se permiten limitaciones a la duración de las garantías implícitas, por lo tanto, en tales casos esta limitación no es aplicable.
B. CUALQUIER PERDIDA DAÑO INCIDENTAL, INDIRECTO O CONSECUENTE QUE PUEDA RESULTAR DE UN DEFECTO,
FALLA O MALFUNCIONAMIENTO DEL PRODUCTO CAMPBELL HAUSFELD. En algunos estados no se permite la exclusión o limitación de daños incidentales o consecuentes, por lo tanto, en tales casos esta limitación o exclusión no es aplicable
C. Cualquier falla que resulte de un accidente, abuso, negligencia o incumplimiento de las instrucciones de
funcionamiento y uso indicadas en el (los) manual(es) que se adjunta(n) al producto. Dichos accidentes, abusos por parte del comprador, o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado también debe incluir la desconexión o modificación de los instrumentos de seguridad. Si dichos
instrumentos de seguridad son desconectados, la garantía quedaría cancelada. D. Los ajustes normales explicados en el(los) manual(es) suministrado(s) con el producto. E. Artículos o servicios normalmente requeridos para el mantenimiento del producto, tales como: anillos en O, resortes,
amortiguadores, defensas, hojas de impulsor, fusibles, baterías
, empaques, almohadillas o sellos, boquillas de fluído,
agujas, boquillas para rociar arena, lubricantes
, mangueras de material, elementos filtrantes, álabes de motores, abrasivos, hojillas, discos para cortar, cinceles, retenes para cinceles, cortadores, collarines, mandriles, mordazas para remachadoras, brocas para desarmadores, almohadillas para lijar
, soportes de almohadillas, mecanismo de impacto o cualquier otro artículo desgastable que no se haya enumerado específicamente . Estos artículos sólo estarán cubiertos bajo esta garantía por noventa (90) días a partir de la fecha de compra original. Los artículos subrayados sólo están garantizados por defectos de material o fabricación.
7. RESPONSABILIDADES DEL GARANTE BAJO ESTA GARANTIA: Reparar o reemplazar, como lo decida el Garante, los productos o componentes que estén defectuosos, se hayan dañado o hayan dejado de funcionar adecuadamente, durante el período de validez de la garantía
8. RESPONSABILIDADES DEL COMPRADOR BAJO ESTA GARANTIA: A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto. B. Entregar o enviar el producto o componente Campbell Hausfeld al Centro de Servicio autorizado Campbell Hausfeld
más cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador.
C. Seguir las instrucciones sobre operación y mantenimiento del producto, tal como se indica(n) en el (los) manual(es) del
propietario
9. CUANDO EFECTUARA EL GARANTE LA REPARACION O REEMPLAZO CUBIERTO BAJO ESTA GARANTIA: La reparación o reemplazo dependerá del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos.
Esta garantía limitada es válida sólo en los EE.UU., Canadá y México y otorga derechos legales específicos. Usted también puede tener otros derechos que varían de un Estado a otro. o de un país a otro.
WARNING
!
WARNING
!
WARNING
!
WARNING
14 Sp
Instrucciones de Funcionamiento
GA230600AV MANOMETRO DE 0 bar A 11,03 bar
• Con armazón negra resistente a impactos y esfera de plástico transparente
• Conexión macho de 3,2 mm (1/8”) NPT
• Lectura en kg/cm2y bar
• Presión entre 0 bar y 11,03 bar
HF201001AV MULTIPLE
• Para reemplazo en la fábrica
• Para conectarse a salidas estándard de 12,7 mm (1/2”) NPT del tanque
• Con conexiones de 6,4 mm y 3,2 mm (1/4” & 1/8”) (hembra) para la manguera y el manómetro
• Válvula de tranque manual para evitar fugas
• Válvula de desfogue preajustada de fábrica para evitar que se llene el tanque en exceso
Repuestos
MP2681 MANGUERA EN ESPIRAL
DE 6,4 mm x 7,62 m (1/4” x 25‘)
• Conectores macho de 6,4 mm (1/4”) NPT en ambos extremos
• Hecha de nylón
MP2167 PISTOLA NEUMÁTICA DE SEGURIDAD
• Conexión hembra de 6,4 mm (1/4”) NPT
• Para manguera MP2681 o otra
manguera de 1/4” NPT con conectores machos
MP3233 MANDRIL RESISTENTE
• Hecho de bronce y zinc
• Conexión hembra de 6,4 mm (1/4”) NPT
• Para manguera MP2681 o otra
manguera de 1/4” NPT con conectores machos
SV895301AV MANGUERA DE AIRE DE 0,91 m (3’)
CON ADAPTADOR UNIVERSAL PARA CONECTARLA A LA LLANTA
• Conector macho de 6,4 mm (1/4”)
• Se conecta al vástago permitiendole trabajar “sin necesidad de sostenerla”
Accesorios opcionales
Dirija toda la correspondencia a:
Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A.
Sirvase darnos la siguiente información:
- Número del modelo
- Número de Serie o código con fecha (de haberlo)
- Descripción y número del repuesto según la lista de repuestos
Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio
3
Operating Instructions
www.chpower.com
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Tank loses air pressure
1. Air shutoff valve leaks
2. Drain valve leaks
3. Gauge leaks
4. Manifold leaks
5. Tank leaks
Tank will not hold enough air
Tank fills slowly
Cannot get air out of tank
Water in tank
Safety relief valve will not open when ring is pulled
Air leaks
1a. Valve not fully closed 1b. Valve defective
2a. Valve not fully closed 2b. Valve connection loose 2c. Valve defective 3a. Gauge damaged 3b. Gauge connection
loose
4a. Manifold damaged or
defective relief valve
4b. Manifold connection
loose
5. Pin hole from internal rusting
1. Gauge not reading correctly
2. Compressed air source below 85 psi
1. Fill valve obstructed or damaged
2. Low volume air output source
1. Low tank pressure
2. Hose shutoff valve closed
3. Universal adapter damaged
Contaminated compressed air source
Defective relief valve
Use mild soapy water to locate leak
1a. Turn valve clockwise to close 1b. Replace manifold
2a. Turn valve clockwise to close 2b. Remove valve, apply thread sealant and tighten 2c. Replace drain valve 3a. Replace gauge 3b. Remove gauge, apply thread sealant and tighten
4a. Replace manifold
4b. Remove manifold, apply thread sealant and tighten
5. Replace tank
1. Check air pressure at fill stem with tire pressure gauge. Replace gauge if gauge reads differently
2. Locate compressed air source of 85 to 125 psi
1. Inspect opening for foreign material, clean or replace
2. Locate compressed air source of 85 to 125 psi
1. Tank pressure must exceed tire pressure. Increase tank pressure
2. Turn red knob on manifold counterclockwise to fully open, 1-1/2 turns
3. Replace hose assembly
Drain water from tank. Refer to maintenance section for instructions
Replace manifold
D-1403 VÁLVULA DE DRENAJE DE 1/4” (6 mm)
• Necesaria para el drenaje adecuado de la humedad contenida dentro del tanque
• Es más segura y mantiene la capacidad del aire
13 Sp
Instrucciones de Funcionamiento
Problema Posible(s) Causa(s) Acción a Tomar
El tanque pierde presión
1. La válvula de cierre de aire tiene pérdidas
2. La válvula de drenaje tiene pérdidas
3. Fuga de aire en el manómetro.
4. Fuga de aire en el múltiple
5. Fuga de aire en el tanque
El tanque no alcanza la presión máxima para la que está diseñado
El tanque se llena lentamente
El tanque no le suministra aire (el aire no sale)
Hay agua en el tanque
La válvula de liberación de seguridad no se abre cuando se tira del anillo
Fugas de aire
1a. La válvula no está
totalmente cerrada
1b. La válvula está
defectuosa
2a. La válvula no está
totalmente cerrada
2b. La conexión de la
válvula está floja
2c. La válvula está
defectuosa
3a. El manómetro está
dañado
3b. La conexión del
manómetro está floja
4a. El múltiple está dañado
o la válvula de seguridad no está funcionado adecuadamente.
4b. La conexión del múltiple
está floja
5. El tanque está oxidado y tiene un orificio pequeño
1. El manómetro no está indicando la presión correcta
2. La presión de la fuente de suministro es inferior a 5,86 bar
1. La válvula de entrada está obstruída o dañada.
2. La presión de la fuente de suministro es muy baja
1. La presión del tanque es muy baja
2. La válvula de cierre de la manguera está cerrada
3.
Adaptador universal dañado
El aire comprimido suministrado está contaminado
La válvula de liberación está defectuosa
Use agua enjabonada para ubicar la fuga
1a. Gire la válvula hacia la derecha para cerrarla
1b. Cambie el distribuidor
2a. Gire la válvula hacia la derecha para cerrarla
2b. Retire la válvula, aplique el sellador de rosca y ajuste
2c.Cambie la válvula de drenaje
3a.Reemplace el manómetro
3b.Desconecte el manómetro, aplíquele un sellador a las
roscas y apriételo
4a.Reemplace el múltiple
4b.Desconecte el múltiple, aplíque un sellador a las roscas y
apriételo
5. Reemplace el tanque
1. Mida la presión del tanque en el vástago de la válvula con un manómetro para llantas. Reemplace el manómetro del tanque si le indica una presión diferente
2. La presión de la fuente de suministro debe ser de 5,86 bar a 8,62 bar
1. Inspeccione el orificio, si está sucio límpielo o reemplace la válvula
2. La presión de la fuente de suministro debe ser de 5,86 bar a 8,62 bar
1. La presión del tanque debe exceder la de la llanta
2. Gire la perilla roja del múltiple en sentido contrario a las manecillas del reloj para abrirla completamente, 1 1/2 vueltas
3. Reemplace el conjunto de la manguera
Drene el agua del tanque. Para las instrucciones, refiérase a la sección de mantenimiento.
Cambie el distribuidor
Guía de Diagnóstico de Averías
4
Operating Instructions
GA230600AV AIR GAUGE 0 TO 160 psi
• Impact resistant black case with clear plastic lens
• 1/8” NPT male fitting
• Reads in psi & kg/cm
2
• Accurate from 0 to 160 psi
HF201001AV AIR MANIFOLD
• Factory replacement part
• Fits standard 1/2” NPT tank spud
• Provides 1/4” & 1/8” female ports for hose and gauge
• Manual shutoff prevents leaks
• Preset safety relief valve prevents overfilling
Replacement Parts
MP2681 1/4” X 25 FT. RECOIL HOSE
• 1/4” NPT male fittings on both ends
• Nylon construction
MP3233 HEAVY-DUTY AIR CHUCK
• Brass and zinc construction
• 1/4” NPT female port
• Use with MP2681 or other hose with 1/4” NPT male ends
SV895301AV 3 FT. AIR HOSE WITH TIRE
UNIVERSAL ADAPTER
• 1/4” male fitting
• Locks onto stem allowing “hands free” filling
Optional Accessories
For Replacement Parts or Technical Assistance, call 1-800-543-6400
Address any correspondence to:
Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A.
Please provide following information:
- Model number
- Stamped-in code
- Part description and number as shown in parts list
www.chpower.com
D-1403 1/4” DRAIN VALVE
• Needed for proper draining of trapped moisture within tank
• Improves safety and preserves air capacity
MP2167 SAFETY BLOW GUN
• 1/4” NPT female port
• Use with MP2681 or other hose with 1/4” NPT male ends
Informaciones Generales de Seguridad (Continuación)
Use gafas de seguridad aprobadas por ANSI Z87.1 durante el funcionamiento para evitar lesiones en los ojos.
• Sólo para aire seci. No lo use para almacenar o rociar liquidos o gases inflamables.
• Almacenamiento cubierto. No lo almacene a la intemperie o en plena luz solar.
• Use solo accesorios con capacidad para un minimo de 10,34 bar.
• Antes de cada uso cerciórese de que las mangueras de aire no estén deterioradas. Igualmente, cerciórese de que todas las conexiones estén bien apretadas.
Use solamente piezas de repuesto y accesorios originales de Campbell Hausfeld cuando realice el servicio de la unidad. Si no lo hace podría provocar la muerte o lesiones graves.
Ensamblaje
La manguera de aire viene desconectada de fábrica para evitar que se dañe en el transporte. Use una llave de 14,3 mm (9/16”) para conectar el extremo de la manguera con el conector macho de 6,4 mm (1/4”) al orificio de salida del múltiple (en el lado opuesto de la válvula de entrada). Apriételo con la mano y déle 2 ó 3 vueltas adicionales.
Funcionamiento
Antes de llenar hale la válvula de alivio de seguridad para asegurarse que la válvula puede actuar libremente.
1. Lleve el tanque de aire a una
fuente de aire comprimido limpio y seco (por ejemplo a una estación de servicio). Algunas estaciones de servicio modernas no tienen el equipo con la presión necesaria para llenar el tanque. La presión
12 Sp
Instrucciones de Funcionamiento
recomendada para llenar el tanque es de 5,86 bar a 8,62 bar.
2. Conecte el mandril de la fuente de suministro de aire a la válvula de entrada ubicada al lado del múltiple de bronce (Vea la Figura 1). Llene el tanque hasta alcanzar una presión máxima de 8,62 bar indicada por el manómetro. La válvula de seguridad está fijada a una presión de 9,31 bar para evitar que se llene el tanque excesivamente.
No se fíe de la válvula de liberación de seguridad para indicar cuando el tanque está lleno.
NOTA: La válvula de cierre (perilla roja) no tiene que abrirse para llenar el tanque.
3. Infle el objeto asegurando el adaptador al vástago de la válvula. Asegúrese de presionar el adaptador universal completamente hacia abajo sobre la rosca del vástago de la válvula. Cuando el adaptador universal esté firmemente colocado en su sitio, presione la palanca de seguro hacia abajo para sujetarlo en el vástago de la válvula (ver Figura 2).
NOTA: El adaptador universal no tiene una válvula. El flujo de aire está controlado por la válvula de cierre de aire ubicada en el distribuidor.
4. Para abrir la válvula de cierre y permitir el flujo de aire hacia la manguera, gírela en sentido contrario a las manecillas del reloj.
El manó-
metro del múltiple del tanque no le indica la presión del objeto que está inflando. Use otro manómetro para medir la presión del objeto.
5. Gire en el sentido de las manecillas
del reloj la válvula de cierre a la posición cerrada antes de soltar el adaptador universal del vástago de la válvula para prevenir pérdidas de aire de la manguera. No apriete demasiado.
Mantenimiento
Es necesario drenar regularmente del tanque la humedad acumulada para prevenir la formación de óxido. El no hacerlo debilita el tanque y puede causar heridas y daños materiales como consecuencia de la explosión o rotura del tanque.
Instrucciones de Drenaje:
1. Libere la presión del tanque
abriendo la válvula de cierre de aire o tirando del anillo de la válvula de seguridad.
2. Abra por completo la válvula de
drenaje en la parte inferior del tanque girándola hacia la izquierda.
3. Permita que salga toda la humedad
que haya en el tanque.
4. Cierre la válvula de drenaje
girándola hacia la derecha. No apriete en exceso.
Servicio Técnico
Para mayor información referente al funcionamiento o reparación de este producto comúniquese con el distribuidor de Campbell Hausfeld más cercano a su domicilio.
Figura 2
Adaptador Universal
Seguro
Vástago de válvula
Figura 1
Manometró Múltiple
Cierre del aire
Válvula de Desfogue de Seguridad
Válvula de Entrada
5
Operating Instructions
www.chpower.com
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the duration of the warranty period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM
THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this product is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY
DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with
instructions provided in the owner’s manual(s) supplied with product. Accident, purchaser's abuse, neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices.
If such safety devices are removed or altered, this warranty is void. D. Normal adjustments which are explained in the owner’s manual(s) provided with the product. E. Items or service that are normally required to maintain the product, i.e. o-rings, springs, bumpers, debris shields,
driver blades
, fuses, batteries, gaskets, packings or seals, fluid nozzles, needles, sandblast nozzles, lubricants, material
hoses, filter elements
, motor vanes, abrasives, blades, cut-off wheels, chisels, chisel retainers, cutters, collets, chucks,
rivet jaws, screw driver bits
, sanding pads, back-up pads, impact mechanism, or any other expendable part not specifically listed. These items will only be covered for ninety (90) days from date of original purchase. Underlined items are warranted for defects in material and workmanship only.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, products or components which are defective, have malfunctioned and/or failed to conform within duration of the warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Deliver or ship the Campbell Hausfeld product or component to the nearest Campbell Hausfeld Authorized Service
Center. Freight costs, if any, must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the United States, Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from state to state or country to country.
!
ADVERTENCIA
!
ADVERTENCIA
!
ADVERTENCIA
!
ADVERTENCIA
!
ADVERTENCIA
!Sírvase leer y consevar estas instrucciones. Lea con cuidado antes de tratar de ensamblar, instalar, operarar o darle mantenimiento al producto descrito. Protéjase Ud. y a los demás observando todas las medidas de seguridad. El no seguir las instrucciones podría ocasionarle heridas y/o daños a su propiedad! Guarde este manual de instrucciones como referencia.
Descripción
Estos tanques de aire portátiles de acero son recipientes presurizados de alta calidad, están soldados y diseñados para transportar aire comprimido para uso doméstico, agrícola o talleres mecánicos.
Este
tanque no tiene certificación ASME. Antes de usarlo, revise los requisitos del código local y estatal.
Para Desempacar
Al desempacar este producto, revíselo con cuidado para cerciorarse de que esté en perfecto estado. Cerciórese de que todas las conexiones, pernos y tuercas estén bien apretados antes de comenzar a utilizar la unidad.
Medidas de Seguridad
Este manual contiene información que es muy importante que sepa y comprenda. Esta información se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO. Debe reconocer los siguientes símbolos.
Ésto le
indica que hay una situación inmediata que LE OCASIONARIA la muerte o heridas de gravedad.
Ésto le
indica que hay una situación que PODRIA ocasionarle la muerte o heridas de gravedad.
Ésto le
indica que hay una situación que PODRIA ocasionarle heridas no muy graves.
Manual de Instrucciones de Funcionamiento Modelos KTV008 y FHV009
IN287000AV 6/04
Ésto le
indica una información importante, que de no seguirla, le podría ocasionar daños al equipo.
Informaciones Generales de Seguridad
Siempre debe seguir las siguientes medidas de seguridad:
Peligro
de explosiones. El no observar las Instrucciones y las Advertencias puede causar la muerte o daños graves.
• Lea con cuidado los
manuales incluidos con este producto. Familiarícese con los controles y el uso adecuado del equipo. Siga todas las instrucciones.
• Esta unidad solo debe ser usada por
personas que estén bien familiarizadas con las reglas de seguridad y manejo.
Nunca
exceda la capacidad máxima de presión del tanque de 8,62 bar. Él hacerlo podría ocasionarle heridas o daños a su persona.
No llene
nunca el tanque de botellas de gas o de cualquier otro sistema que produzca más de 10,43 bar.
• No altere ni manipule la válvula de
alivio de seguridad. La manipulación o alteración de la válvula de seguridad invalida las garantías existentes y Campbell Hausfeld rechaza cualquier responsabilidad
Tanque de Aire Portátil
© 2004 Campbell Hausfeld/Scott Fetzer
Advertencia sobre
el aire respirable
Este tanque no está equipado y no se debe usar para suministrar aire respirable.
por pérdidas, heridas y daños.
• El tanque tiene una etiqueta ubicada en el mango con la inscripción “DISCARD AFTER” (desechar después de) y la fecha. Deshágase del tanque y NO lo utilice después de esta fecha. Reemplácelo por un tanque nuevo.
NUNCA trate de reparar o modificar un tanque. Si lo solda, taladra o le hace cualquier otro tipo de modificaciones lo dañaría y podría ocasionar rupturas o explosiones. Siempre reemplace los tanques desgastados, dañados o agrietados.
Para liberar la presión de
aire del tanque antes de darle servicio o reemplazar piezas, jale el anillo de la válvula de seguridad.
RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía!
Adjúntela a este manual o archívela en lugar seguro.
Ver la Garantía en página 15 para información importante sobre el uso comercial de este producto.
S’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder avec l’entretien du produit décrit. Se protéger ainsi que les autres en observant toutes les instructions de sécurité, sinon il y a risque de blessure et/ou dégâts matériels. Conserver ces instructions comme référence.
Description
Les réservoirs à air portatifs sont des récipients de pression soudés de haute qualité conçus pour transporter l’air comprimé pour l’usage domestique, automobile et sur la ferme.
Ce
réservoir n'a pas de certification ASME. Avant d'utiliser, vérifier les exigences des codes locaux et d'État.
Déballage
Lors du déballage de ce produit, l’examiner soigneusement pour rechercher toute trace de dommage susceptible de s’être produit en cours de transport. S’assurer que tous raccords, boulons, etc. desserrés soient serrés avant d’utiliser le modèle.
Directives de Sécurité
Ce manuel contient de l’information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D’ÉQUIPEMENT. Rechercher les symboles suivants pour cette information.
Danger
indique une situation hasardeuse imminente qui RÉSULTERA en perte de vie ou blessures graves.
Avertis-
sement indique une situation hasardeuse potentielle qui PEUT résulter en perte de vie ou blessures graves.
Attention
indique une situation hasardeuse potentielle qui PEUT résulter en blessures.
Avis
indique de l’information importante pour éviter le dommage de l’équipement.
Instructions d’Utilisation Modèles KTV008 et FHV009
IN287000AV 6/04
Généralités Sur La Sécurité
Toujours observer les mesures de sécurité suivantes:
Risque
d'explo­sion. Ne pas suivre les avertissements et les instructions pourrait provoquer la mort ou de graves blessures.
• Lire attentivement tous les
manuels, y compris celui de ce produit. Bien se familiariser avec les commandes et l’utilisation correcte de l’équipement. Suivre toutes les instructions.
• Seules les personnes bien
familiarisées avec ces règles d’utilisation en toute sécurité doivent être autorisées à se servir de l’outil pneumatique.
Ne jamais remplir le réservoir plus que 862 kPa. Ceci peut causer des blessures personnelles ou le dégât matériel.
Ne
rem­plissez jamais du gaz en bobonne ou de tout système d'air qui produit plus de 1034 kPa.
• Ne pas modifier ou altérer avec toute
soupape de sûreté. Advenant le cas où la soupape de sûreté soit altérée, les garanties seront annulées et Campbell Hausfeld décline toute responsabilité quelconque pour toute perte, blessures ou dommages.
• Ce réservoir porte la mention «
JETER APRÈS » la date étampée sous la poignée. Après cette date, mettre le réservoir au rebut et NE L’UTILISEZ
Réservoir à Air Portatif
© 2004 Campbell Hausfeld/Scott Fetzer
Avertissement D’Air Respirable
Ce réservoir n'est pas prévu et ne doit pas être utilisé pour fournir de l'air respirable.
PAS. Remplacez avec un nouveau réservoir.
NE JAMAIS essayer de réparer ni de modifier un réservoir. Le soudage, perçage ou n’importe quelle modification peut affaiblir le réservoir et peut causer la rupture ou une explosion. Toujours remplacer les réservoirs usés, endommagés ou fendus.
• Dissiper la pression d’air du réservoir à air en tirant sur l’anneau de sûreté avant le service ou le remplacement de pièces.
Porter des lunettes de sécurité ANSI approuvées Z87.1 en utilisant l'appareil pour éviter les blessures oculaires
Il est nécessaire de porter des lunettes de protection pendant l’utilisation.
MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité.
Voir la Garantie à la page 10 pour de l’information importante sur l’utilisation commercial de ce produit.
DÉNÉGATION DES GARANTIES Si le réservoir est utilisé pour les applications d'air respirable, les garanties en cours seront annulées et Campbell Hausfeld dénie toute responsabilité quelconque pour toute perte, blessure personnelle ou dommage.
INVALIDAR LAS GARANTIAS
En caso de que el tanque se use con el fin de suministrar aire respirable, las garantías existentes serán inválidas y Campbell Hausfeld niega toda responsabilidad por pérdidas, daños o lesiones personales.
BUILT TO LAST
!
DANGER
!
AVIS
!
DANGER
!
AVERTISSEMENT
!
ATTENTION
AVIS
DANGER
!
DANGER
!
DANGER
MANUEL
!
DANGER
!
AVERTISSEMENT
!
AVERTISSEMENT
BUILT TO LAST
AVISO
!
PELIGRO
AVISO
!
PELIGRO
!
ADVERTENCIA
!
PRECAUCION
!
PELIGRO
!
PELIGRO
!
PELIGRO
MANUAL
!
PELIGRO
10 Fr
Instructions d’Utilisation
Instructions d’Utilisation
Généralités Sur La Sécurité (Suite)
• Pour l'air sec seulement. N'utilisez pas pour ranger ou disperser des liquides ou des gaz inflammables.
• Rangez à l'intérieur. Ne rangez pas à l'extérieur ou dans les rayons du soleil.
• Utilisez seulement les accessoires d'une valeur nominale d'au moins 1034 kPa.
• Vérifier les tuyaux d’air pour rechercher tout signe de faiblesse ou d’usure avant chaque utilisation. S’assurer que tous les branchements soient bien serrés.
Utiliser seulement des pièces de rechange et des accessoires Campbell Hausfeld authentiques en réparant l'appareil. Le non-respect de cette directive pourrait mener à des blessures graves ou à la mort.
Montage
Le tuyau à air n’est pas branché pendant l’expédition afin d’empêcher le dommage. Utiliser une clé ouverte de 14,3 mm (9/16 po) pour brancher le bout du tuyau fileté mâle d’1/4 po NPT à la sortie d’air sur le collecteur (sens opposé de la soupape de remplissage). Serrer à la main et encore 2-3 tours de plus.
Fonctionnement
Tirez la soupape de sûreté avant de remplir pour vous assurer que la soupape se déplace librement.
1. Remplir le réservoir portatif avec
une source d’air comprimé propre et sèche (une station-service ou un routier par exemple). (Quelques stations-services modernes n’ont pas de pression suffisante pour remplir le réservoir). La pression de remplissage recommandée est entre 586 et 862 kPa (85 et 125 psi).
2. Placer le raccord de la source d’air
sur la soupape de remplissage située près du collecteur en laiton
(Voir Figure 1). Remplir le réservoir au maximum de 862 kPa (125 psi) tel qu’indiqué sur le manomètre. La soupape de sûreté est réglée d’avance à 931 kPa (135 psi) pour empêcher la surpressurisation.
Ne pas compter sur la soupape de sûreté pour indiquer que le réservoir est plein.
REMARQUE: Il n’est pas nécessaire d’ouvrir la soupape d’arrêt d’air (bouton rouge) pour remplir le réservoir.
3. Gonfler l'objet en verrouillant l'adaptateur universel dans la tige de la soupape. S’assurer de pousser l’adaptateur universel complètement par dessus les filets de la tige de soupape. Une fois que l’adaptateur universel soit fermement en place, appuyer sur le levier d’arrêt afin de le verouiller sur la tige de soupape (Voir Figure 2).
REMARQUE : L'adaptateur universel n'a pas de robinet. Le débit d'air est contrôlé par la soupape d'arrêt d'air sur le collecteur.
4. Ouvrir la soupape d’arrêt d’air en tournant au sens inverse des aiguilles d’une montre afin de permettre le débit d’air dans le tuyau.
Le
mano­mètre du réservoir n’indique pas la pression de l’objet de gonflage. Utiliser un autre manomètre pour l’objet.
5. Tourner la soupape d'arrêt d'air
dans le sens des aiguilles d'une montre à la position fermée avant de déverrouiller l'adaptateur universel de la tige de la soupape pour éviter les fuites d'air du boyau. Ne pas trop resserrer.
Entretien
L'humidité accumulée doit être vidangée du réservoir régulièrement pour éviter la rouille. Sinon, le réservoir sera affaiblit ce qui pourrait mener à des blessures ou des dommages à la propriété suite à l'éclatement ou à la rupture du réservoir.
Instructions de Drainage:
1. Dégager la pression du réservoir en
ouvrant la soupape d'arrêt d'air ou en tirant l'anneau sur la soupape de sûreté.
2. Ouvrir complètement le robinet de
vidange au bas du réservoir en tournant dans le sens contraire des aiguilles d'une montre.
3. Laisser toute l'humidité du réservoir
se drainer.
4. Fermer le robinet en tournant dans
le sens des aiguilles d'une montre. Ne pas trop resserrer.
Service Technique
Pour des informations concernant le fonctionnement du produit, composer le 1-800-543-6400.
7Fr
Figure 2
Adaptateur Universel
Verrouiller
Tige de Soupape
Figure 1
Manomètre Prise d’air
Soupape d’ar
rêt
d’air
Soupape de Sûreté
Soupape de Remplissage
Garantie Limitée
1. DURÉE: À partir de la date d’achat par l’acheteur original comme suit - Un An
2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400
3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld.
4. PRODUITS COUVERTS PAR CETTE GARANTIE: Tous les outils de fixation (cloueuses et agrafeuses), outils pneumatiques, pistolets vaporisateurs, gonfleurs ou accessoires pneumatiques Campbell Hausfeld qui sont fournis par ou fabriqués par le Garant.
5. COUVERTURE DE LA PRÉSENTE GARANTIE: Défauts de matière et de fabrication considérables qui se révèlent pendant la période de validité de la garantie.
6. LA PRÉSENTE GARANTIE NE COUVRE PAS: A. Les garanties implicites, y compris celles de commercialisabilité et D’ADAPTION À UNE FONCTION PARTICULIÈRE
SONT LIMITÉES À PARTIR DE LA DATE D’ACHAT INITIALE TELLE QU’INDIQUÉE DANS LA SECTION DURÉE. Si ce produit est utilisé pour une fonction commerciale, industrielle ou pour la location, la durée de la garantie sera quatre-vingt-dix (90) jours à compté de la date d’achat. Quelques Provinces (États) n’autorisent pas de limitations de durée pour les garanties implicites. Les limitations précédentes peuvent donc ne pas s’appliquer.
B. TOUT DOMMAGE, PERTE OU DÉPENSE FORTUIT OU INDIRECT POUVANT RÉSULTER DE TOUT DÉFAUT, PANNE OU
MAUVAIS FONCTIONNEMENT DU PRODUIT CAMPBELL HAUSFELD. Quelques Provinces (États) n’autorisent pas l’exclusion ni la limitation des dommages fortuits ou indirects. La limitation ou exclusion précédente peut donc ne pas s’appliquer.
C. Toute panne résultant d’un accident, d’une utilisation abusive, de la négligence ou d’une utilisation ne respectant
pas les instructions données dans le(s) manuel(s) accompagnant le produit. Un accident, l’utilisation abusive par l’acheteur, la négligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l’enlevage ou la modification de n’importe quel appareil de sûreté. Si ces appareils de sûreté sont enlevés ou
modifiés, la garantie sera annulée. D. Réglages normaux qui sont expliqués dans le(s) manuel(s) d’utilisation accompagnant le produit. E. Articles ou services qui sont exigés pour l'entretien du produit; Joints torique, ressorts, amortisseurs, écrans de
débris, lames d'entraînement, fusibles, batteries
, joints d'étanchéité, garnitures ou joints, buses de fluide, aiguilles,
buses de sablage, graisses
, tuyaux de matériaux, cartouches filtrantes, pales de moteur, abrasifs, lames, meules de coupage, burins, fixe-burins, coupeuses, douilles de serrage, mandrins. mâchoires de rivet, lames de tournevis, tampons de sablage, tampons de sauvegarde, mécanisme de percussion ou toute pièce qui n’est pas indispensable et qui n’est pas indiquée. Ces articles seront couverts pour quatre-vingt-dix (90) jours à partir de la date d'achat original. Les articles soulignés sont garanties pour défauts de matière et de fabrication seulement
.
7. RESPONSABILITÉS DU GARANT AUX TERMES DE CETTE GARANTIE: Réparation ou remplacement, au choix du Garant, des produits ou pièces qui se sont révélés défectueux pendant la durée de validité de la garantie.
8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. Livraison ou expédition du produit ou de la pièce Campbell Hausfeld au Centre De Service Autorisé Campbell
Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
C. Utilisation et entretien du produit avec un soin raisonable, ainsi que le décri(vent)t le(s) manuel(s) d’utilisation.
9. RÉPARATION OU REMPLACEMENT EFFECTUÉ PAR LE GARANT AUX TERMES DE LA PRÉSENTE GARANTIE: La réparation ou le remplacement sera prévu et exécuté en fonction de la charge de travail dans le centre de service et dépendra de la disponabilité des pièces de rechange.
Cette Garantie Limitée s’applique aux É.-U., au Canada et au Mexique seulement et vous donne des droits juridiques précis. L’acheteur peut également jouir d’autres droits qui varient d’une Province, d’un État ou d’un Pays à l’autre.
!
AVERTISSEMENT
!
AVERTISSEMENT
!
AVERTISSEMENT
!
AVERTISSEMENT
9Fr
Instructions d’Utilisation
GA230600AV MANOMÈTRE 0 À 1103 kPa
• Boîtier noir résistant au choc avec lentille en plastique claire
• Raccord mâle 1/8 po NPT
• Lire en psi et kg/cm2
• Précis de 0 à 1103 kPa
HF201001AV COLLECTEUR D’AIR
• Pièce de rechange de l’usine
• S’ajuste à un raccord de réservoir standard de 1/2 po NPT
• Fournit des orifices femelles de 6,4 et 3,2 mm pour le tuyau et manomètre
• Arrêt manuel empêche les fuites
• Soupape de sûreté réglée d’avance empêche le sur-remplissage
MP2681 TUYAU RECUL, 6,4 MM X
7,62 M
• Raccords mâles d’1/4 po NPT aux deux extrémités
• Construction en nylon
MP2167 SOUFFLETTE DE SÉCURITÉ
• Orifice femelle d’1/4 po NPT
• Utiliser avec MP2681 ou autre tuyau à extrémité mâle de 1/4 po NPT
MP3233 RACCORD À AIR ROBUSTE
• Construction en laiton et en zinc
• Orifice femelle d’1/4 po NPT
• Utiliser avec MP2681 ou autre tuyau à extrémité mâle de 1/4 po NPT
SV895301AV TUYAU À AIR DE 91,4 CM AVEC
ADAPTATEUR DE PNEUS UNIVERSEL
• Raccord mâle de 6,4 mm
• Se fixe au système permettant le remplissage “sans main”
Accessoires en Option
8Fr
Instructions d’Utilisation
Guide de Dépannage
Symptôme Cause(s) Possible(s) Mesures Correctives
Perte de pression
1. Fuite de soupape d'arrêt
2. Fuite du robinet de vidange
3. Fuite au manomètre
4. Fuite au collecteur
5. Fuite au réservoir
Le réservoir ne tient pas assez d’air
Le réservoir se remplit lentement
L’air ne sort pas du réservoir
Eau dans le réservoir
La soupape de sûreté ne s'ouvre pas en tirant l'anneau
Fuites d’air
1a. Soupape n'est pas
fermée complètement
1b. Soupape défectueuse
2a. Soupape n'est pas
fermée complètement
2b. Connexion de soupape
desserrée 2c. Soupape défectueuse 3a. Manomètre
endommagé 3b. Raccordement du
manomètre dégagé 4a. Manomètre endom-
magé ou soupape de
sûreté défectueuse 4b. Raccord du collecteur
dégagé
5. Trou d’épingle causé
par la rouille intérieure
1. Manomètre incorrect
2. Source d’air comprimé sous 586 kPa
1. Soupape de remplissage obstruée ou endommagée
2. Source d’air de basse volume
1. Pression de réservoir basse
2. Soupape d’arrêt du tuyau fermée
3. Adaptateur universel endommagé
Source d’air comprimé viciée
Soupape de sûreté défectueuse
Utiliser l’eau savonneuse pour trouver la fuite
1a. Tourner la soupape dans le sens des aiguilles d'une montre
pour fermer
1b. Remplacer le collecteur
2a. Tourner la soupape dans le sens des aiguilles d'une montre
pour fermer
2b. Retirer la soupape et appliquer du mastic de jointement,
puis resserrer 2c. Remplacer le robinet de vidange 3a. Remplacer le manomètre
3b. Enlever le manomètre, mettre de l’agent d’étanchéité
pour filets et serrer 4a. Remplacer le collecteur
4b. Remplacer le collecteur, utiliser du mastic pour filets et
serrer
5. Remplacer le réservoir
1. Vérifier la pression d’air à la tige de remplissage avec un manomètre pour pneus. Remplacer le manomètre au besoin
2. Rechercher une source d’air comprimé entre 586 et 862 kPa
1. Inspecter l’ouverture pour des matières étrangères, nettoyer ou remplacer
2. Rechercher une source d’air comprimé entre 586 et 862 kPa
1. La pression du réservoir doit dépasser la pression du pneu. Augmenter la pression du réservoir
2. Tourner le bouton rouge sur le collecteur au sens inverse des aiguilles d’une montre afin d’ouvrir complètement 1 1/2 tours
3. Remplacer l'assemblage du tuyau
Vidanger l'eau du réservoir. Se reporter à la section d'entretien pour les instructions
Remplacer le collecteur
Pièces Détachées
Pour Pièces de Rechange ou assistance technique, appeler 1-800-543-6400
S’il vous plaît fournir l’information suivante:
- Numéro du modèle
- Code Estampé
- Description et numéro de la pièce
Adresser toute correspondance à :
Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A.
D-1403 ROBINET DE VIDANGE DE 1/4 PO (0,6 CM)
• Nécessaire pour une bonne vidange de l'humidité du réservoir
• Améliore la sécurité et conserve la capacité d'air
Loading...