Campbell Hausfeld CW301300AJ, CW301400AJ User Manual

Additional Operating Instructions and Parts Manual CW301300AJ, CW301400AJ
MANUAL
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Pressure Switch Assembly for Portable Air Compressors
Figure 1 - Old Pressure Switch
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . .1
Safety Guidelines . . . . . . . . . . . . . . . . .
General Safety Information . . . . . . . . .
Components . . . . . . . . . . . . . . . . . . . . .2
Removal of Existing Switch . . . . . . . . .
New Switch Installation . . . . . . . . . . . .
Operation Procedure . . . . . . . . . . . . . .
Replacements Part Information. . . . . .
Description
all
Figure 2 - New Pressure Switch Assembly
Unpacking
After unpacking the kit, inspect carefully for any damage that may have occurred during transit, before putting
1
unit into service.
1
READ & FOLLOW ALL INSTRUCTIONS
2 2 3 4
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Warning indicates a
potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a
potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
NOTE: Information that requires special attention.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
GENERAL SAFETY
• Read all manuals included
with this product carefully. Be thoroughly familiar with the controls
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN606402AV 8/08© 2008 Campbell Hausfeld/Scott Fetzer
Additional Operating Instructions and Parts Manual
MTR
LINE
MTR
LINE
1
2
3
4
General Safety Information (Continued)
and the proper use of the equipment. Follow all instructions.
• Only persons well acquainted with these rules of safe operation should be allowed to use the unit.
Components
Pressure switch - Auto/Off Switch - In
the "
AUTO" position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure. In the "
OFF" position, the compressor will not operate. This switch should be in the "
OFF" position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools.
Regulator - The regulator controls the amount of air pressure released at the hose outlet.
ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
Pressure Gauges - The gauge attached to pressure switch will show air pressure in tank. The gauge attached to regulator will show air pressure at the hose outlet.
Removal of Existing Switch
1. Disconnect power and release all air
pressure from tank.
2. Remove existing pressure switch
cover screw(s), then remove cover.
3. Locate cut-outs on the back of
pressure switch (See Figure 3). Insert
Ground Screw
Cutouts
Figure 3
www.chpower.com
Strain Relief Screw
tip of small screwdriver into cutouts, then push to release wires.
4. Remove ground screw (See Figure 3).
5. Remove strain relief screw (See Figure 3).
6. Pull unloader tube off existing pressure switch. Remove screw holding pressure switch to pressure switch assembly. Then remove switch from unit.
7. Disconnect unloader tube from check valve.
8. Remove the remainder of pressure switch assembly by unscrewing tank
fitting.
New Switch Installation
New switch must
have same maximum pressure as existing switch. Pressure rating is listed on the bottom of assembly.
1. Screw pressure switch assembly onto
tank.
2. Replace existing unloader tube
connection at check valve with new quick connect supplied in kit.
3. Insert new unloader tube into quick
connect fitting on check valve.
4. Insert other end of unloader tube
into unloader valve on pressure switch. Unloader tube can be cut if supplied length is too long.
5. Loosen pressure switch cover screw,
then remove cover.
6. Two strain relief clamps will be
provided in the kit. Determine which strain relief clamp to use based on the diameter of the line cord.
7. Loosely attach strain relief clamp to
pressure switch with screw provided in kit. Insert motor and line cord into switch. Tighten strain relief clamp screw to hold cords securely.
8. Position black motor wire
underneath screw head #4 (See Figure 4), then tighten screw to secure wire. Position black line wire underneath screw head #2, then tighten screw to secure wire.
9. Position white line wire underneath
screw head #1, then tighten screw
Ground terminals
Figure 4
to secure wire. Position white motor wire underneath screw head #3, then tighten screw to secure wire (See Figure 4).
10. Attach green ground wire from line cord to inside of pressure switch with ground screw provided in kit. Repeat procedure with green ground wire from motor cord. (See Figure 4).
11. Place cover on pressure switch and tighten cover screw.
12. Screw regulator onto pressure switch.
NOTE: Ensure air flow indicator arrow on regulator body points away from compressor (See Figure 5).
13. Attach outlet pressure gauge to regulator.
Hose Outlet
Air Flow
Figure 5
2
CW301300AJ, CW301400AJ
A
U
T
O
/
O
F
F
MANUAL
Operating Procedure
In the "AUTO" position, the compressor pumps air into tank. It shuts off automatically when unit reaches its maximum preset pressure. In the "OFF" position, the pressure switch cannot function and the compressor will not operate.
IMPORTANT: Read instructions before operating compressor or damage may result.
1. Turn switch to "OFF" position and plug in power cord (See Figure 6).
2. Turn switch to "AUTO" position to run unit (See Figure 6).
Notes
3. Turn regulator knob fully counterclockwise. Compressor will build to maximum preset pressure and shut off.
4. Attach end of hose to regulator knob. Turn regulator clockwise to increase pressure going to the tool that is being used.
This switch should
be in the "OFF" position when connecting or disconnecting the power cord from the electrical outlet.
Figure 6
www.chpower.com
3
Additional Operating Instructions and Parts Manual
O
T
U
A
F
F
O
For Replacement Parts or Technical Assistance,
Call 1-800-543-6400
Please provide following information: Address any correspondence to:
- Model number Campbell Hausfeld
- Serial number (if any) Attn: Customer Service
- Part description and number as shown in parts list 100 Production Drive
Harrison, OH 45030 U.S.A.
1
11
10
4
5
6
9
8
7
7
Figure 7 – Replacement Parts Illustration for Pressure Switch Assembly for Portable Air Compressors
Replacement Parts List
2
3
Reference Number Description Part Number Quantity
1 Pressure Switch (CW301300AJ) CW211200AV 1 Pressure Switch (CW301400AJ) CW213100AV 1 2 Unloader Tube ST117803AV 1 3 Quick Connect ST081301AV 1 4 Clamp Screw ST209800AV 1 5 Strain Relief Clamp (ST/SJT) CW209500AV 1 Strain Relief Clamp (SJT/SJT) CW209600AV 1 6 Bushing Reducer ST071407AV 1 7 Pressure Gauge GA016300AV 2 8 1/4 inch Nipple HF002401AV 2 9 Regulator RE206203AV 1 10 ASME Safety Valve (140 psi) (CW301300AJ) V-215100AV 1 ASME Safety Valve (115 psi) (CW301400AJ) V-215102AV 1 11 Unloader Valve CW210001AV 1 12 Ground Screw ST074407AV 2
www.chpower.com
4
Loading...