Campbell TGA200 Instruction Manual

TGA200 Trace Gas Analyzer
Overview
9/11
Copyright © 2011
Campbell Scientific, Inc.
Warranty
Assistance
Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company serves
your country.
To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. Campbell Scientific's shipping address is:
CAMPBELL SCIENTIFIC, INC. RMA#_____ 815 West 1800 North Logan, Utah 84321-1784
For all returns, the customer must fill out a "Statement of Product Cleanliness and Decontamination" form and comply with the requirements specified in it. The form is available from our web site at www.campbellsci.com/repair. A completed form must be either emailed to repair@campbellsci.com or faxed to (435) 227-9579. Campbell Scientific is unable to process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer's expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees.
TGA200 Overview Table of Contents
PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections.
1. System Components ...................................................2
2. Theory of Operation ....................................................3
2.1 Optical System..........................................................................................3
2.2 Laser Scan Sequence ................................................................................4
2.3 Concentration Calculation ........................................................................5
3. Trace Gas Species Selection......................................5
4. Multiple Ramp Mode.................................................... 6
5. User Interface...............................................................6
6. Specifications ..............................................................7
Figures
Tables
6.1 Measurement Noise ..................................................................................7
6.2 TGA200 Frequency Response..................................................................8
6.3 Physical Specifications ...........................................................................10
1-1. TGA200 system components ..................................................................2
2-1. Schematic diagram of TGA200 optical system.......................................3
2-2. TGA200 laser scan sequence ..................................................................4
5-1. Real-time graphics screen........................................................................6
6-1. Concentration time series showing response of TGA200 .......................9
6-2. Frequency response of the TGA200........................................................9
6-1. Typical Concentration Measurement Noise ............................................7
6-2. Typical Concentration Measurement Noise for Multiple Scan Lasers....7
6-3. Typical Isotope Ratio Measurement Noise .............................................8
i
Loading...