Campbell PVS4100C, PVS4100D Specifications

COMPONENTS
PVS4100C and PVS4100D
Portable Automatic Liquid Samplers
Biggest,
PVS4100C
Overview
Fastest Pump
Vacuum technology
for better samples
PVS4100D
into up to 24 containers. These samplers have a bigger pump than our other portable water samplers allowing them to support the fastest sampling rates and longest sampling distances.
Benets and Features
Rapid transport velocities of samples (horizontal draws 76.2 m (250 ft) at 0.8 m s-1 (2.5 ft s-1), meaning more accurate samples, even of solids
Controller housed in an environmentally sealed enclosure for corrosion protection, and all information is easily controlled and viewable on a 2 by 16 character backlit LCD
Composite or discrete models available
Side handles for easy lifting (increases diameter) Interfaces with Campbell Scientic dataloggers for more
measurement and control capabilities Stainless-steel suspension harness* available for sampling
in sewer systems Handcart* available for easy transport
Options*
Quick connect terminals Power supply options: 80 to 264 Vac with a 17 A h battery or
80 to 264 Vac without a battery Water Detection Probe Warranty options: three or ve year
*For a complete list of options and accessories, refer to: www.campbellsci.com/pvs4100c-ordering or www.campbellsci.com/pvs4100d-ordering
Sample container options: no bottles, 9 L bottle (PVS4100C only), 24 0.5 L bottles (PVS4100D only), or 24 1 L bottles (PVS4100D only)
PVS4100C size options: 3/8 in. ID system or 5/8 in. ID system (the PVS4100D Discrete Sampler is a 3/8 in. ID system only)
questions & quotes: 435.227.9000
campbellsci.com/water-samplers
Campbell Scientic, Inc.
815 W 1800 N
Logan, UT 84321-1784
(435) 227-9000
www.campbellsci.com
Technical Details
Vacuum Pump
The PVS4100C and PVS4100D samplers use an external vacuum pump to draw water through intake tubing, instead of the tra­ditional peristaltic pump that induce ow by squeezing exible tubing. Because the vacuum method disturbs the water samples less, they better represent the original water solution, especially if the solution has high concentrations of suspended solids. To prevent cross contamination, the samplers use air pressure (up to 28 psi) to purge the tubing of excess water. See our vacuum pump water samplers in action at:
www.youtube.com/watch?v=wi4dxFTw-ks
Specications
Enclosure: Molded medium density linear polyethylene, three piece construction and stainless-steel ttings
Cooling System: Insulated container wall cavity space for ice Height: 80.9 cm (31.875 in.) Height with extended base: 96.2 cm (37.875 in.) Body Case Diameter: 42.8 cm (16.85 in.) Sampler Weight, no battery: 11.8 kg (26 lb) Battery Weight: 6.8 kg (15 lb)
Vacuum System
Pinch Valve: Fixed – normally open Purge Cycle: Adjustable from 1 to 99 s Suction Cycle: Variable (adjusts automatically to double the
input value of the purge time setting or until liquid contacts level electrode in metering chamber
Metering Chamber Cover: Nylon Volume Control Tube: 316 stainless steel Metering Chamber Level Electrode: 316 stainless steel Intake Hose: ordered as a common accessory. Campbell Scientic
oers PVC hose with 25 ft and user-specied lengths. Intake end can have a lead sinker or stainless-steel strainer. Sampler end can have a clamp or quick connect termination.
Discharge Hose Material: Latex
Controller/Interfacing with a Datalogger
The PVS4100C and PVS4100D include a programmable controller with 16-key intuitive touch pad. The controller can accept a pulse input (e.g., rain gage), a 4 to 20 mA signal (e.g., ow meter), or initiate a sample on a timed basis. See a demonstration of the programmable controller at:
www.youtube.com/watch?v=yRr80Lm-5Hs
The sampler can also be interfaced with our dataloggers. Our dataloggers can measure nearly any turbidity, water level, or hydrometeorologic sensor, as well as control the sampler based on time, event, or measured conditions.
Controller
LCD: 2 x 16 character backlit LCD Touchpad: 16 key with multi-level menu Start Delay: Disabled; Time/Day; Pulse Count; 4 to 20 mA
(0 to 100 pulses/min.); External Contact; Level Control Sample Initiation: Disabled; Time/Day; Pulse Count; 4 to 20 mA
(0 to 100 pulses/min.); External Contact Program Type: Composite; Multi-Composite; Consecutive; Daily
Cycle; Timed Step Clock: Real-time clock and operating system Direct Function Keys: Manual sample; Manual purge; Manual
bottle advance; Restart Switches: Controller on/o (SPST toggle) Available Displays: Real-time clock; process timing; process
totals; pulse counting; event response; multilevel descriptions; ashing prompts; diagnostics
Automatic Displays: Container Full; Fault; Power Interrupt (pro­gram resumed); Alternating Time Stamp; Cycle(s) abandoned
Backup Power Source: Internal lithium battery to maintain program settings and information in case of power failure
Power Requirements
DC Output: 13.6 Vdc, 10 A AC Input: 88 to 264 Vac, 50/60 Hz, 2.5 A (nominal), 3 A (maximum) Backup Battery: 12 Vdc Quiescent Current Drain: 61 mA
Horizontal Velocity
System Size
3/8 in. system
5/8 in. system
(PVS4100C only)
7.6 m (25 ft) 15.2 m (50 ft) 22.9 m (75 ft) 30.5 m (100 ft) 53.3 m (175 ft) 61 m (200 ft) 76.2 m (250 ft)
-1
2.2 m s
(7.1 ft s-1)
1.5 m s
USA | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | ENGLAND | FRANCE | GERMANY | SOUTH AFRICA | SPAIN
-1
(5 ft s-1)
1.9 m s-1
(6.2 ft s-1)
1.4 m s-1
(4.7 ft s-1)
|
1.7 m s-1
(5.6 ft s-1)
1.3 m s-1
(4.3 ft s-1)
|
Distance
1.5 m s-1 (5 ft s-1)
1.28 m s-1 (4.2 ft s-1)
|
1.2 m s-1 (4 ft s-1)
1.1 m s-1
(3.7 ft s-1)
|
1.1 m s-1
(3.7 ft s-1)
1 m s-1
(3.3 ft s-1)
0.8 m s-1
(2.6 ft s-1)
0.7 m s-1
(2.4 ft s-1)
© 2011, 2013
Campbell Scientic, Inc.
September 25, 2013
Loading...