Campbell PT100/3 User Manual

Page 1
PT100/3
1/3 DIN PRT
Probe
User Manual
Copyright
1994, 2010 Campbell Scientific Ltd.
©
CSL146
Page 2
Page 3
Guarantee
This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery. We will repair or replace products which prove to be defective during the guarantee period provided they are returned to us prepaid. The guarantee will not apply to:
x Equipment which has been modified or altered in any way without the
written permission of Campbell Scientific
x Batteries
x Any product which has been subjected to misuse, neglect, acts of God
or damage in transit.
Campbell Scientific will return guaranteed equipment by surface carrier prepaid. Campbell Scientific will not reimburse the claimant for costs incurred in removing and/or reinstalling equipment. This guarantee and the Company’s obligation thereunder is in lieu of all other guarantees, expressed or implied, including those of suitability and fitness for a particular purpose. Campbell Scientific is not liable for consequential damage.
Please inform us before returning equipment and obtain a Repair Reference Number whether the repair is under guarantee or not. Please state the faults as clearly as possible, and if the product is out of the guarantee period it should be accompanied by a purchase order. Quotations for repairs can be given on request.
When returning equipment, the Repair Reference Number must be clearly marked on the outside of the package.
Note that goods sent air freight are subject to Customs clearance fees which Campbell Scientific will charge to customers. In many cases, these charges are greater than the cost of the repair.
Campbell Scientific Ltd,
Campbell Park, 80 Hathern Road,
Shepshed, Loughborough, LE12 9GX, UK
Tel: +44 (0) 1509 601141
Fax: +44 (0) 1509 601091
Email: support@campbellsci.co.uk
www.campbellsci.co.uk
Page 4
Page 5
PLEASE READ FIRST
About this manual
Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American market. Some spellings, weights and measures may reflect this origin.
Some useful conversion factors:
Area: 1 in
Length: 1 in. (inch) = 25.4 mm
1 ft (foot) = 304.8 mm 1 yard = 0.914 m 1 mile = 1.609 km
In addition, while most of the information in the manual is correct for all countries, certain information is specific to the North American market and so may not be applicable to European users.
Differences include the U.S standard external power supply details where some information (for example the AC transformer input voltage) will not be applicable for British/European use. Please
note, however, that when a power supply adapter is ordered it will be suitable for use in your country.
Reference to some radio transmitters, digita l cell phones and aerials may also not be applicable according to your locality.
Some brackets, shields and enclosure options, including wiring, are not sold as standard items in the European market; in some cases alter n a tives are offered. Details o f the alternatives will be covere d in separate manuals.
Part numbers prefixed with a “#” symbol are special order parts for use with non-EU variants or for special installations. Please quote the full part number with the # when ordering.
2
(square inch) = 645 mm2
Mass: 1 oz. (ounce) = 28.35 g 1 lb (pound weight) = 0.454 kg
Pressure: 1 psi (lb/in
Volume: 1 UK pint = 568.3 ml
1 UK gallon = 4.546 litres 1 US gallon = 3.785 litres
2
) = 68.95 mb
Recycling information
At the end of this product’s life it should not be put in commercial or domestic refuse but sent for recycling. Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility.
Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases arrange collection and the correct disposal of it, although charges may apply for some items or territories.
For further advice or support, please contact Campbell Scientific Ltd, or your local agent.
Campbell Scientific Ltd, Campbell Park, 80 Hathern Road, Shepshed, Loughborough, LE12 9GX, UK
Tel: +44 (0) 1509 601141 Fax: +44 (0) 1509 601091
Email: support@campbellsci.co.uk
www.campbellsci.co.uk
Page 6
Page 7
Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections.
1. Specifications .............................................................. 1
2. Installation .................................................................... 1
3. Programming ............................................................... 2
4. Calibration .................................................................... 2
Figure
1. Schematic of PT100/3 Probe ...................................................................... 2
i
Page 8
Page 9
PT100/3 1/3 DIN PRT Probe
Platinum resistance thermometers are high-stability temperature measurement devices suitable for very wide temperature ranges (-200ºC to +650ºC). The PT100/3 probe can be used for both 3-wire half bridge and 4-wire half bridge measurements when used with the appropriate Campbell Scientific Terminal Input Module (TIM).
1. Specifications
Element: 1/3 DIN (to IEC60751)
Typical PRT Element Error: <±0.15ºC @ -100ºC <±0.1ºC @ 0ºC <±0.19ºC @ +100ºC <±0.31ºC @ +200ºC (excluding datalogger and bridge resistor accuracy)
Maximum temp. of standard probe: +80ºC (see Note below)
Standard cable length: 3m
NOTE
2. Installation
The operating temperature range for the probe is limited by the type of cable and operating conditions. The PVC cable fitted to the standard probe should not be used at temperatures above 80ºC. If the cable is subject to flexing, the lower temperature limit is -20ºC. However, if the cable is rigidly fixed, without the possibility of flexing, the probe can be used in temperatures down to -50ºC.
Other cable types are available to special order to cover temperatures in the range of -200ºC to + 650ºC.
The probe can be connected in a 3-wire half bridge or a 4-wire half bridge configuration. To accomplish this it shoul d be used with the appropriate Campbell Scientific Terminal Input Module (TI M) which contains the necessary completion resistors and connects directly to the datalogger’s input terminals.
The 4-wire half bridge offers the best accuracy, and requir es the 4WPB100 Terminal Input Module. This module contains both the 10kΩ and the 100Ω resistors needed. However, two differential (i.e. four single-ended) channels are required on the datalogger for 4-wire half bridge measurements. One 4WPB100 module can be shared by several probes when used with an AM416 multiplexer.
The 3-wire half bridge only requires two single-ended channels on the datalogger, and is used with the 3WHB10K Terminal Input Module, which contains the 10kΩ resistor.
For more information about the installation and use of the TIMs, please refer to the appropriate TIM manual.
1
Page 10
3. Programming
User Manual
Figure 1 Schematic of PT100/3 Probe
(two alternate colour schemes shown – depends on cable type)
Program examples for using a PRT with all t ypes of Campbell Scientific dataloggers are shown in the appropriate TIM manua l. Addi t iona l exam ples are also given in the individual datalogger manuals.
4. Calibration
The PT100/3 probe and its associated TIM can be used without any additional calibration if that is appropriate to your field requirements. Note that the calibration at 0ºC procedure described in the TIM manuals will rem ove offse t errors in the PRT element and in the 0.01% tolerance of the 10kΩ completion resistor. However, it will not remove any temperature c oefficient error in the bridge resistor in the 4-wire half bridge, nor any slope error inherent in the PT100 element.
2
Page 11
Page 12
CAMPBELL SCIENTIFIC COMPANIES
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321 UNITED STATES
www.campbellsci.com
Campbell Scientific Africa Pty. Ltd. (CSAf)
Somerset West 7129
www.csafrica.co.za
Campbell Scientific Australia Pty. Ltd. (CSA)
QLD 4812 AUSTRALIA
www.campbellsci.com.au
Campbell Scientific do Brazil Ltda. (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
www.campbellsci.ca
Campbell Scientific Centro Caribe S.A. (CSCC)
300N Cementerio, Edificio Breller
Santo Domingo, Heredia 40305
www.campbellsci.cc info@campbellsci.cc
Campbell Scientific Ltd. (CSL)
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
www.campbellsci.fr
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
www.campbellsci.es
Campbell Scientific Ltd. (Germany)
Fahrenheitstrasse13, D-28359 Bremen
www.campbellsci.de
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
info@campbellsci.com
PO Box 2450
SOUTH AFRICA
sales@csafrica.co.za
PO Box 444
Thuringowa Central
info@campbellsci.com.au
suporte@campbellsci.com.br
CANADA
dataloggers@campbellsci.ca
COSTA RICA
Campbell Park
80 Hathern Road
sales@campbellsci.co.uk
FRANCE
info@campbellsci.fr
08013 Barcelona
SPAIN
info@campbellsci.es
GERMANY
info@campbellsci.de
Loading...