Campbell CS220, CS220-L Information

COMPONENTS
CS220
Surface-Mount Type-E Thermocouple Sensor
Fast Response
Ideal for monitoring
solar panel temperature
Overview
The CS220 thermocouple measures the temperature of a surface by direct contact. It typically monitors the temperature of a solar panel, but can also monitor the temperature of other devices.
Benets and Features
Well-suited for solar energy applications Thermocouple tolerance meets ASTM E230-ANSI MC 96.1
(reference junction at 0°C)
Type E Thermocouples
Type E thermocouples are comprised of a chromel wire and a constantan wire joined at a measurement junction. A voltage potential is generated when the measurement end of the ther­mocouple is at a dierent temperature than the “reference end” of the thermocouple. The magnitude of the voltage potential is related to the temperature dierence. Therefore, temperature can be determined by measuring the dierences in potential created at the junction of the two wires
Panel temperature is an important measurement in solar energy applications since the output of a solar panel is aected by its temperature. As the temperature of the solar panel increases, its output decreases.
Easy to install Compatible with most Campbell Scientic dataloggers
A reference temperature measurement (typically measured at the datalogger wiring panel) is required. Options for measuring the reference temperature include:
Thermistor built into the CR800, CR850, CR1000, CR3000, or CR5000 wiring panel
PRT built into the wiring panel of the CR9050 or CR9051E input module for the CR9000X Measurement and Control System
1
1
e CS220 is not compatible with our CR200(X)-series or CR510 dataloggers.
questions & quotes: 435.227.9000
www.campbellsci.com/cs220
Campbell Scientic, Inc.
815 W 1800 N
Logan, UT 84321-1784
(435) 227-9000
www.campbellsci.com
Installation
The CS220 usually adheres in the center of the back panel of a so­lar module. Once the mounting location is determined, clean the back panel surface. Use extreme caution removing the masking paper from the measurement end of the thermocouple; damage can occur if masking paper is not removed carefully. Once mask­ing paper is removed, rmly press thermocouple to the panel. Adhere the cable strain relief 2 to 3 in. from the end. Connect the mini connector on the stainless-steel overbraided cable to the mini connector on the thermocouple extension cable. Wire the pigtails of the thermocouple extension cable to the datalogger, as determined by the datalogger program/wiring table.
Wiring Table
Datalogger Channel
Wire Color Wire Label
Purple Signal Di. High SE Channel
Red
Clear Shield or AG
Signal
Reference
Dierential
Measurements
Di. Low or AG
Single-ended
Measurements
Thermocouple Extension Cable
Pigtails
Overbraided Cable
Mini Connector
Mini Connector
The CS220 is shipped with a stainless-steel overbraided cable and a thermocouple extension cable. The pigtails of the extension cable connect to the datalogger (see Wiring Table).
Mini Connectors
Stainless Steel
Overbraided Cable
Thermocouple with Self-
Adhesive Backing
Thermocouple Extension Cable
The mini connectors of the thermocouple extension and overbraided cables attach to each other (shown above). Adhesive under the masking paper secures the sensor to a solar panel.
Ordering Information
Thermocouple
CS220-L Type E Surface Mount Fast Response Thermocouple. Enter the
Common Accessory
27015 Roll of Kapton tape for locations where the temperature
cable length, in feet, after the –L. The recommended cable length is 50 ft (CS220-L50). Specify a cable length of zero feet (CS220-L0) to get a replacement sensor that includes the stainless-steel overbraided cable, but not the thermocouple extension cable.
may exceed 70°C.
USA | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | ENGLAND | FRANCE | GERMANY | SOUTH AFRICA | SPAIN
|
|
Specications
Thermocouple Type: Chromel-Constantan
Typical Output: 60 μV/°C
Thermocouple Tolerances (reference junction at 0°C): Meets ASTM E230-ANSI MC 96.1 Special Limits of 1.0°C or 0.4% (0° to 900°C)
Maximum Temperature of Adhesive: adheres for up to 260°C
Accuracy: Refer to the “Thermocouple Measurement” section in
your datalogger manual
Length of Stainless-Steel Braided Cable: 1.0 m (3.3 ft)
Thermocouple Length: 2.54 cm (1.00 in)
Thermocouple Width: 1.91 cm (0.75 in)
Weight with 50-ft cable: 238 g (8.4 oz)
|
|
Campbell Scientic, Inc.
© 2009, 2013
July 25, 2013