Critical Installation Warnings
● Install in recreation vehicles only. RV’s are recreation vehicles designed as temporary
living quarters for recreation, camping, or travel use having their own power or towed by
another vehicle.
● All combustion air must be supplied from outside the RV, and all products of combustion
must be vented to outside the RV.
● DO NOT vent water heater with venting system serving another appliance.
● DO NOT vent water heater to an outside enclosed porch area.
● Protect building materials from flue gas exhaust.
● Install water heater on an exterior wall, with access door opening to outdoors.
● DO NOT modify water heater in any way.
● DO NOT alter water heater for a positive grounding system.
● DO NOT HI-POT water heater unless electronic ignition system (circuit board) has been
disconnected.
● DO NOT use battery charger to supply power to water heater even when testing.
Do not install close to opening door or under room slide-out where the vent or inlet louvers
can be obstructed.
● This appliance shall be installed by authorised persons only and in accordance with these
installation instructions, AS5601.2, local gas fitting regulations, municipal building codes,
electrical wiring regulations, local water supply regulations and any other statutory
regulations.
● Remove every packaging and transit protection in- and outside of the water heater
● This appliance shall be installed by authorised persons only and in accordance with these
installation instructions, AS5601.2, local gas fitting regulations, municipal building codes,
electrical wiring regulations, local water supply regulations and any other statutory
regulations.
Installation Instructions for the IWH-1.5 Water Heater
The IWH-1.5 water heater is designed to be installable and removable from the exterior of
the vehicle. The mounting instructions are for the PrecisionTemp surface mount door. No
other door should be used. Doing so will void the warranty and cause the heater to
malfunction and could cause damage or injury.
Please read these instructions before making any modifications to the construction of your
caravan or RV.
Selecting Installation Location
Review the following guidelines carefully before choosing the location for the water heater
and ensure the location complies with the requirements of the current edition of AS5601.2
before installation. The water heater must not be installed in an area where the vent can be
covered when any door or access panel on the coach is opened. The water heater should be
located in an area where leakage will not result in damage to other items of, or in the
structure. If such an area cannot be avoided, it is recommended that a suitable pan and drain
be installed under the heater.
Install the heater as close to the gas supply as practical to minimize length of the gas line.
There must be a minimum of 25 cm of clearance between the vent cover and any other
surface. Do not install where the vent is closer than 40 cm from any window or opening into
the coach. Do not block or restrict door louvers, this will damage the IWH-1.5.
Although the IWH-1.5 can be mounted with zero clearance around the sides, top and bottom,
be sure that the installation does not interfere with any wiring, plumbing or cabinets inside the