CAME MR8204 Quick Start Manual

MR8204
.
Opening & safety sensor for automatic sliding doors
Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
DESCRIPTION
1
2
3
ENGLISH
5 6
7
4
1. cover
2. radar antenna (wide fi eld)
3. radar fi eld size adjustment
4. IR-prism (2 m)
TECHNICAL SPECIFICATIONS
Supply voltage: Power consumption: Mounting height: Sensitivity of the test input: Temperature range: Degree of protection: Noise: Expected lifetime: Norm conformity:
Detection mode:
Technology:
Angle: Output:
Hold time output signal: Response time on test request:
User’s Guid e for produc t version 0100 and higher. See product label for serial number.
12 V - 30 V DC -5%/+10% < 2.2 W
1.8 m to 3 m < 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C IP54 < 70 dB 20 years R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU; EN 16005:2012;
EN 12978:2009; EN IEC 62061:2005 SIL2, EN 61496-1:2012 ESPE Type 2; EN ISO 13849-1:2008 Pl «c»
Motion Min. detection speed: 5 cm/s Microwave doppler radar Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm2 From 15 ° to 50 ° vertical (adjustable) Solid-state-relay (free of potential, free of polarity) Max. contact current: 100 mA Max. contact voltage: 42 V AC/DC
0.5 s
Specifi cations a re subject t o changes wit hout prior n otice. All values measured in specifi c conditions
5. main connector
6. IR-angle adjustment
7. push button for setup or DIP-setting confi rmation
8. DIP-switch
(to be operated from SELV compatible power supplies only)
CAT.2 (under the condi tion that the door contro l system monitors th e sensor at least once pe r door cycl e)
GREEN LED
0.3 s to 1 s (not adjustable) Typical: < 5 ms
RED LED
8
MR82 04 / FA0 0025 M06 ☜󱽚☞ V IO-DT2 / 42 .8274 / v2 - 0 2.15
0
1
MOUNTING & WIRING
CLOSER
AWAY
1
max. 5 cm
The door control unit and the door cover profi le must be correctly earthed.
RADAR FIELD - OPENING IMPULSE
2
MIN MAX
2.2 m
FIELD SIZE
12-30 V DC
RELAY R1
RELAY R2
GREEN
BROWN
YELLOW
1
1
1
Output status when sensor is o peratio nal
2
For compliance with EN 16005, conn ection
to door cont roller test output is required.
2.2 m
WHITE
SENSOR
PINK
GREY
RED
BLUE
2
2
ANGLE
+
POWER SUPPLY
-
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
+
TEST OUTPUT
-
2.2 m
GREEN LED
1 x 0.5 m
INFRARED FIELD - SAFETY
3
WIDTH
0
1
2
3
W
0
1
2
3
2 m
Detection fi eld width indicated acco rding to condi tions defi n ed in EN 16005 a nd including d imension of t est body C A.
max.
ANGLE
5 cm
MR82 04 / FA0 0025 M06 ☜󱽚☞ V IO-DT2 / 42 .8274 / v2 - 0 2.15
H
2
1
H W
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.8 0 m
DOOR
4 x 2 m
The size of th e detecti on fi eld varie s according to t he mounting height of the s ensor.
Check position of IR-curtains with Spotfi nder and adjust if necessary.
ORANGE
@ 2.2 m: Depth of curtain : 8-10 cm Depth of safety fi eld: 25 cm*
* in standard presetting
fi eld size: max
«click»
CLOSER
AWAY
RED LED
SETTINGS (by DIP-switch)
4
PRESETTINGS
critical
environment
standard
1
Can only be used if DIP 4 is OFF.
2
Not available on MR8204. If selected, the presetting «standard» is applicable.
3
Enhanced IR-immunity which excludes EN 16005-conformity of the door system.
4
The opening relay (R1) is activated in ca se of detec tion in th e radar or infrared fi eld.
hospital
shopping
street
2
1
ENVIRONMENT RELAY R1 ACTIVATION
extreme
standard
3
motion
or
presence
motion
standard: standard environments (factory setting)
critical environment: enhanced immunity (rain, snow, lamps...) and only 1 IR-curtain activated.
shopping street: optimized for narrow sidewalks > the opening relay (R1) is activated in case of detec tion in radar + IR-fi eld.
hospital: optimized for persons with reduced mobility (PRM)
After changing a DIP-s witch, the orange LED fl ashes. A LONG push on the push button confi rms the setting.
Always launch a setup after changes of the DIP-settings.
5
+
SETUP
ORANGE
OFF
LONG (> 3s)
Step outside of the infrared fi eld before launching a setup.
4
QUICK SETUP
ASSISTED SETUP
+
OPEN+CLOSE
SHORT
RED-GREEN OFF
LONG (> 3s)
TIP: Launch an ASSISTED SETUP to verify wiring, position of the curtains and correct functioning of the sensor.
SAFETY INSTRUCTIONS
- Test the good functioning of the installation before leaving the premises.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
RED-GREEN
OFF
MR82 04 / FA0 0025 M06 ☜󱽚☞ V IO-DT2 / 42 .8274 / v2 - 0 2.15
LED-SIGNALS
The ORANGE LED fl ashes quickly.
The ORANGE LED fl ashes 1 x.
1
The ORANGE LED fl ashes 2 x.
2
The ORANGE LED fl ashes 4 x.
4
The ORANGE LED fl ashes 5 x.
5
The ORANGE LED is on.
The RED LED fl ashes quickly after an assisted setup.
The RED LED lights up sporadically.
The GREEN LED lights up sporadically.
A DIP-switch was changed without confi rmation.
The sensor signals an internal fault.
Irregularities in the power supply
The sensor receives not enough IR-energy.
The sensor receives too much IR-energy.
The sensor encounters a memory problem.
The sensor sees the door during the assisted setup.
The sensor vibrates.
The sensor sees the door.
The sensor is disturbed by lamps or another sensor.
The sensor is disturbed by the rain.
The sensor is disturbed by rain and/or leaves.
Ghosting
The sensor vibrates.
The sensor sees the door or other moving objects.
1
Confi rm the DIP-settings by a long push on the push button.
Cut and restore power supply.
1
If orange LED fl ashes again, replace sensor.
2
1
Check power supply. Check wiring.
2
Use the 1 m prism if possible (accessory).
1
Check the angle of the IR-curtains.
2
Use a low energy prism if possible (accessory).
1
Check the angle of the IR-curtains.
2
Cut and restore power supply.
1
If orange LED lights up again, replace sensor.
2
1
Check the angle of the IR-curtains. Launch a new assisted setup.
2
Attention: Do not stand in the detection fi eld!
Check if the sensor is fastened fi rmly.
1
Check position of prism and cover.
2 1
Launch an assisted setup and adjust the IR angle.
1
Choose the critical environment presetting (DIP 1+2).
1
Choose the critical environment presetting (DIP 1+2).
Choose the critical environment presetting (DIP 1+2).
1
Change radar antenna angle.
1
1
Check if the sensor is fastened fi rmly.
2
Check position of cable and cover. Remove the objects if possible.
1
Change radar fi eld size.
2
Check connections to test output.
The LED is off.
The reaction of the door does not correspond to the LED-signal.
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
MR82 04 / FA0 0025 M06 ☜󱽚Original instructions󱽚☞ V IO-D T2 / 42. 8274 / v2 - 02 .15
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC. Only trained and qualifi ed personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid touching any electronic and optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV) TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.it - www.came.it Came S.p.A. hereby declares that MR8204 is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/CE. Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE) Original upon request.
BUY-TO-SELL PRODUCT
1
If your door controller is not able to test the sensor,
2
connect the red and blue cable to the power supply.*
Change the activation mode of relay R1 (DIP 4).
1
Loading...