![](/html/43/434c/434cd1cca8033eb8a6c74099df74d0edb5ec9a611cbd56ee00e420d50d4803d0/bg1.png)
MR8204
Opening & safety sensor
for automatic sliding doors
Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
DESCRIPTION
1
2
3
ENGLISH
5
6
7
4
1. cover
2. radar antenna (wide fi eld)
3. radar fi eld size adjustment
4. IR-prism (2 m)
TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Norm conformity:
Detection mode:
Technology:
Angle:
Output:
Hold time output signal:
Response time on test request:
User’s Guid e for produc t version 0100 and higher. See product label for serial number.
12 V - 30 V DC -5%/+10%
< 2.2 W
1.8 m to 3 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
< 70 dB
20 years
R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU; EN 16005:2012;
EN 12978:2009; EN IEC 62061:2005 SIL2, EN 61496-1:2012 ESPE Type 2; EN ISO 13849-1:2008
Pl «c»
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
From 15 ° to 50 ° vertical (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.5 s
Specifi cations a re subject t o changes wit hout prior n otice. All values measured in specifi c conditions
5. main connector
6. IR-angle adjustment
7. push button for setup or DIP-setting confi rmation
8. DIP-switch
(to be operated from SELV compatible power supplies only)
CAT.2 (under the condi tion that the door contro l system monitors th e sensor at least once pe r door cycl e)
GREEN
LED
Presence
Typical response time: <256 ms
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 5 ms
RED
LED
8
MR82 04 / FA0 0025 M06 ☜☞ V IO-DT2 / 42 .8274 / v2 - 0 2.15
![](/html/43/434c/434cd1cca8033eb8a6c74099df74d0edb5ec9a611cbd56ee00e420d50d4803d0/bg2.png)
MOUNTING & WIRING
1
max. 5 cm
The door control unit and the door cover profi le must be correctly earthed.
RADAR FIELD - OPENING IMPULSE
2
MIN MAX
2.2 m
FIELD SIZE
12-30 V DC
RELAY R1
RELAY R2
GREEN
BROWN
YELLOW
1
1
1
Output status when sensor is o peratio nal
2
For compliance with EN 16005, conn ection
to door cont roller test output is required.
2.2 m
WHITE
SENSOR
PINK
GREY
RED
BLUE
2
2
ANGLE
+
POWER SUPPLY
-
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
+
TEST
OUTPUT
-
2.2 m
GREEN
LED
1 x 0.5 m
INFRARED FIELD - SAFETY
3
WIDTH
0
1
2
3
W
0
1
2
3
2 m
Detection fi eld width indicated acco rding to condi tions defi n ed in EN 16005 a nd including d imension of t est body C A.
max.
ANGLE
5 cm
MR82 04 / FA0 0025 M06 ☜☞ V IO-DT2 / 42 .8274 / v2 - 0 2.15
H
2
1
H W
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.8 0 m
DOOR
4 x 2 m
The size of th e detecti on fi eld varie s according to t he mounting height of the s ensor.
Check position of IR-curtains with
Spotfi nder and adjust if necessary.
ORANGE
@ 2.2 m:
Depth of curtain : 8-10 cm
Depth of safety fi eld: 25 cm*
* in standard presetting
fi eld size: max
«click»
CLOSER
AWAY
RED
LED