Came MR8105 Installation Manual

CANCELLI AUTOMATICI
TECHNICAL SPECIFICATIONS
Technology : microwave and
microprocessor
Frequency emitted : 24.125 GHz Power density emitted : << 5 mW/cm
2
Mounting height : 5 m max Tilt angles : 0° to 90° vertical
: –30° to +30° lateral
Detection area (typical) : 4 m (W) x 2,5 m (D) Detection mode : motion Minimum speed : 5 cm/s (measured in axis
of radar)
Supply voltage : 12 to 24 V AC ±10%
: 12 to 24 V DC +30 %/–10 %
Mains frequency : 50 to 60 Hz Power consumption :< 2W Standard output relay (free potential contact)
• Max contact voltage : 60 V DC / 42 V AC
• Max contact current : 1 A (resistive)
• Max switching power : 30 W (DC) / 60 VA (AC)
Output hold time : 0.5 s to 9 s (adjustable) Manual adjustments
• sensitivity (by push buttons)
• orientation of sensing field (mechanically)
Remote control adjustments
• sensitivity
• hold time
• multiple functions
Temperature range : from –20°C to +55°C Immunity : electromagnetic compatibility
(EMC) in accordance with 89/336/EEC
Dimensions : 120 mm (W) x 80 mm (H) x
50 mm (D)
Weight : 0.215 kg Material : ABS Colour of housing : anthracite grey, aluminium
finish or white
Length of cable : 2.5 m Degree of protection : IP54
DESCRIPTION OF THE SENSOR
Terminal block Push buttons +/–
Led Adjustment of
vertical position of antenna
Planar antenna Adjustment of
lateral position of antenna
Wire opening
footprints
Cover viewed
from inside
INTERNAL VIEW
INSTALLATION TIPS
• The sensor must be firmly fastened in order not to vibrate
• The sensor must not have any object likely to move or vibrate in its sensing field
• No fluorescent lighting in the sensing field
• The sensor must not be placed directly behind a panel or any kind of material
AUTOMATIC DOORS
MICROWAVE RADAR - BIDIRECTIONAL
MR8105
Documentazione
Tecnica
M88
rev. 0.5
02/2002
©
CAME
AUTOMATICI
119PM88-GB
ENGLISH
OPENING THE SENSOR
PREPARATION FOR MOUNTING THE SENSOR
From behind, before installation From the front, after installation
CONNECTING AND MOUNTING THE SENSOR
OTHER MOUNTING OPTIONS
Paste the template
Drill as instructed
Insert screws but do not screw them
fully home
If possible, pass the cable where it is supposed to go through
If you dont want to drill your profile for the cable, you can cut the wire opening footprint as shown in the picture
Position the sensor and tighten the two screws. Make sure you leave enough cable to reach the terminal block
12-24 V AC/DC
COM NO NC
OOOOO
1. This device may be fixed on the ceiling, as long as the spherical part of the
sensor is facing the direction opposite the door, and as long as an angular position of around 70° is chosen for the antenna. The vertical tilt angle of the antenna must be set at the maximum position of 75°
23451
70°
For a mounting on the upper part of the door operator profile, use the EBA support
2
ENGLISH
SETTING THE SENSING FIELD DIMENSIONS
To obtain a sensing field as close to the door as possible : the tilt angle of the antenna must be set at the minimum position (0°)
To obtain a sensing field close to the door : the tilt angle of the antenna must be set at the position 20°
- Example of use with a very deep operator
- Example of use with a normal operator
A. THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL TILT ANGLE OF
THE ANTENNA
0°
20°
0°
3