“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS”
1 Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
ENGLISH
2 Intended use and application
2.1 Intended use
The A1824 operator is designed to automate swing gates used in residential or condominium settings..
The use of this product for purposes other than those described above and installation executed in a manner other
than as instructed in this technical manual are prohibited.
2.2 Application
Length of gate leaf1 m1,5 m1,8 m
Weight of gate leaf250 kg215 kg200 kg
3 Reference Standards
The company CAME cancelli automatici s.p.a. is ISO 9001:2000 quality certified; it has also obtained the ISO 14001 environmental safeguarding certification. Came engineers and manufactures all of its products in Italy.
This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.
4 Description
4.1 Gate Operator
This product is engineered and manufactured by CAME cancelli automatici s.p.a. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The gearmotor is made up of two aluminium alloy half shells housing the Encoder gearmotor – which features an electric blocking
mechanism – and an epicyclical reduction system with endless screw.
4.2 Technical features
Control board power supply: 230V A.C. 50/60Hz
Motor power supply: 24V D.C.
Max draw: 4A
Power: 100W
Adjustable thrust:400÷2000N
Opening time (90°): Adjustable
Gear ratio: 1/36
Duty Cycle: Intensive use
Protection Rating: IP44
Weight: 7,5 kg
#
#
2
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
4.3 Description of parts
A1824
1) Operator
2) Pilaster bracket
3) Gate bracket
4) Screw, bushing and nut for the pilaster
bracket
5) Bolt and nut for the gate bracket
6) Distanziale per perno attacco
4.4 Dimensions
1
ENGLISH
6
5
4
2
3
5 Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
(mm)
Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage;
• Fit tubing to drain away any water leaks which may cause oxidation;
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra
•
insulation as compared to the other conductive parts inside;
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving
parts;
• Make sure there is a mechanical stop for opening and closing.
3
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and
compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by
the installer.
ENGLISH
5.3 Cable list and minimum thickness
Connections
Type of
cable
Control panel power supply 230V
Motor power supply 24V3 x 1 mm
Flashing light2 x 0,5 mm
Photocell transmitters2 x 0,5 mm
Photocell receivers4 x 0,5 mm
FROR CEI
20-22
CEI EN
50267-2-1
Accessories power supply2 x 0,5 mm
Control and safety devices 2 x 0,5 mm
Length of cable
1 < 10 m
3G x 1,5 mm
2
2
2
2
2
2
2
Length of cable
10 < 20 m
3G x 2,5 mm
3 x 1,5 mm
2 x 1 mm
2 x 0.5 mm
4 x 0,5 mm
2 x 0,5 mm
2 x 0,5 mm
2
2
2
2
2
2
2
Length of cable
20 < 30 m
3G x 4 mm
3 x 2,5 mm
2 x 1,5 mm
2 x 0,5 mm
4 x 0,5 mm
2 x 1 mm
2 x 0,5 mm
2
2
2
2
2
2
2
AntennaRG58max. 10 m
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the
basis of the actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual
power draw and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said
products.
5.4 Standard installation
6
1) A1824 operator
2) Control panel
3) Reception antenna
4) Flashing light
5) Selector switch
6) Photocells
7) Electric cable junction box
8) Mechanical gate stops
4
3
6
1
5
8
2
1
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
8
7
4
5.5 Installing the operator
The following illustrations are only examples, given that the space available for anchoring the operator and accessories
may vary from gate to gate. It is up to the installer, thus, to choose the most suitable solution.
Lay the corrugated tubing needed for the connections deriving from the junction box.
N.B. the number of tubes depends on the type of system and accessories employed.
Electric cable junction box
Warning: after establishing the best point to which you will secure the gate bracket, secure the bracket to the pillar and make sure
the quotas shown in the table below are met.
Note: by increasing measure B, the opening angle and gate speed are reduced, while the gearmotor thrust is increased. By
increasing the measure A, the opening angle and gate speed are increases, while the gearmotor thrust is decreased.
ENGLISH
Ideal securing
point
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
Gate bracketPillar bracket
Opening
A
(mm)
B
(mm)
C
(mm)
90°13013060
120°13011050
5
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.