AUTOMATION FOR SWING GATES
INSTALLATION MANUAL
ATI SERIES
A 3024 N
A 5024 N
![](/html/98/98e1/98e14f8f80b00981b0d86ede652a50d634fe168c6c685b71868c01783a72d1d6/bg2.png)
2
ENGLISH
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
Control board power supply: 230 A.C. 50/60Hz
Motor power supply: 24V D.C. 50/60Hz
Max draw.: 10A
Power: 120W
Opening time (90°): adjustable
Gear ratio: 1/36
Duty Cycle: Intensive use
Protection Rating: IP44
Weight: 10 kg
Operating temperature
4.1 Gearmotor
This product is engineered and manufactured by C AME CA NCELL I AUTOMAT ICI S.p.A. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The gearmotor is composed of two, cast aluminium half shells inside of which rest the gearmotor and endstops – with electro
blocking – and an endless screw, epicycloidal gear reduction system.
4 Description
2.1 Intended use
1 Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
2 Intended use and restrictions
The ATI 24V N gearmotor is specifi cally engineered to automate residential and condominium swing gates, even under intensive
use.
3 Reference Standards
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS”
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS”
2.2 Restrictions
The use of this product for purposes other than those described above and installation executed in a manner other than as instructed
in this technical manual are prohibited.
4.2 Technical features
The company: Came Cancelli Automatici is ISO 9001:2000 quality certified; is has also obtained the ISO 14001 environmental
safeguarding certification. Came engineers and manufactures all of its products in Italy.
This product complies with the following standards: see declaration of compliance.
4.3 Description of parts
1
2
3
4
1) Operator
2) Front bracket
3) Back swivel-joint
4) Back bracket
#
#
![](/html/98/98e1/98e14f8f80b00981b0d86ede652a50d634fe168c6c685b71868c01783a72d1d6/bg3.png)
3
ENGLISH
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
4.4 Overall dimensions
Measurements in mm
Gate leaf width Gate leaf weight
mkg
2.00 800
2.50 600
3.00 400
Gate leaf width Gate leaf weight
mkg
2.00 1000
2.50 800
3.00 600
4.00 500
5.00 400
Before installing, do the following:
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• That measurement C is not greater than the value shown in Tab. 3, p. 4. In this case you need to work on the pillar until said measurement is obtained;
• Make sure the path of the electrical cables complies with the command and safety instructions;
• That there is a (soundly secured to the ground) mechanical stop to prevent the gate leaf/gearmotor from over extending.
• Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insula-
tion as compared to the other conductive parts inside;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5 Installation
5.1 Preliminary checks
Travel
Travel
Pillar
Gate leaf
End stop
Hinge
A 3024N
A 5024N
![](/html/98/98e1/98e14f8f80b00981b0d86ede652a50d634fe168c6c685b71868c01783a72d1d6/bg4.png)
4
ENGLISH
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning.
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
N.B.: If the cable length differs from that specifi ed in the table, then you must determine the proper cable diameter in the basis of the
actual power draw by the connected devices and depending on the standards specifi ed in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
5.3 Cable list and minimum thickness
Connections Type of cable Length of cable 1 < 10 m Leng. cable 10 < 20 m Leng. cable 20 < 30 m
Control panel power supply 230V 2F
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Flashing light 24V 2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photocell transmitters 2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photocell receivers 4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V Accessories power supply 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Command buttons 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Endstop 3 x 0,5 mm
2
3 x 1 mm
2
3 x 1,5 mm
2
Encoder plug 2402C 22AWG max. 30 m
Antenna connection RG58 max. 50 m
1) Operator
2) Control panel
3) Radio receiver
4) Photocells
5.4 Standard installation
1
1
2
3
4
4 5
4
4
6
7
8
5) Selector switch
6) Antenna
7) Flashing light
8) Transmitter