Camden Door Controls CX-PS13V3 Installation Instructions

CX-PS13V3
Variable Output Linear P ow er Supply
Installation Instructions
Camden CX-PS13V3 is a cost effective
mounted with the supplied adhesive tape
PS13V3 is suitable for electric
PS10UL/30UL/60UL models.
Input Voltage**
6 – 24 VAC depending Output voltage selected
Output Voltage
6, 12, 24 VDC Selectable or 2- 24 VDC if ADJ is selected
Output Protection
PPTC Resettable fuse
Output Power
800mA., 200mA charging current
Ripple
< 40mV.
Efficiency
12VDC = 85%, 24VDC = 90%
Dimensions
2.70” (68.6mm) L x 1.50” (38.1mm) W x H 1.750” (45.5mm) H
the CX­strikes and other electrified devices. For Mag Locks, where UL/ULC Listed power supply is required, we suggest our CX-
Specifications
** See table on back of page.
CX-PS13 V3 Installation Instructions
www.camdencontrols.com Toll Free: 1.877.226.3369
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
File: CX-PS13V3_Manual_NF.doc
IMPORTANT
Output
Required
Transformer
Volts
VA
6 VDC
6 – 9 VAC
20
9 VDC
9 – 12 VAC
20
12 VDC
12 – 14 VAC
30
13.8 VDC
14 – 16 VAC
30
18 VDC
18 – 20 VAC
30
24 VDC
24 – 26 VAC
40
Wiring Diagram
Gell Cell
Battery
To Load
Input
From Transformer
Voltage Selection
Jumpers
Transformer Selection
Voltage
Adjustment
Output Voltage
Input transformer required.
DO NOT connect circuit to
the 120 VAC line.
Revised: July 2012 Part No.: 40-82B104
Loading...