This Package Includes:
1- ESP1B, ESP3B and ESP4B faceplates
4- Wire nuts
5- M5 x 12mm screws
2- #10 x 1 1/4” wood screws
2- #10-32 x 1/2” screws
2- Mounting brackets
2- Spacers
1- Varistor
1. Description
Camden CX-ED2071 low prole Grade 2 ANSI strike for cylindrical locksets offers the very best strike quality and performance, with three stainless steel faceplates provided. The ‘Universal’ strike design delivers unparalleled application exibility, fail safe/fail secure operation and mechanical adjustment of the strike body.
CX-ED2071
Electric Strike
Installation Instructions
3. Dimensions
2. Specifications
Voltage
Current Draw
Static Strength
Dynamic Strength
Endurance
Mode
Mech. Adjustment
Operation
Duty
Dimensions (Body)
8/16V AC/DC
305mA@8V DC 190mA@8V AC 625mA@16V DC 460mA@16V AC
1,000 Lbs.
50 Ft-Lbs.
700,000 Cycles
Field Selectable Fail Safe/Fail Secure
Strike Body/Faceplate
AC-Buzz DC-Silent
Intermittent
3 3/8” H x 1 7/8” W x 1 7/32” D (86mm x 47mm x 31mm)
(104mm)
4 7/8”
(123mm)
3 3/8”
(86mm)
5/8”
(16mm)
4 1/8”
1 7/32”
(31mm)
1 7/32”
(31mm)
1/8”
(3mm)
1 7/8”
(47mm)
1 1/4”
(32mm)
1 5/8”
(42mm)
3/4”
(19mm)
1 1/4”
(32mm)
1 7/32”
(31mm)
1/2”
(12mm)
Page 1 of 3
Page 2
4. Installation
Jamp
CX-ED2071 Electric Strike
1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
3. Spacers are used to assure ush nal assembly of faceplate into jamb. Add one of more spacers between jamb and mounting bracket when face plate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting
Mounting Bracket
Spacer
Spacer (Option)
M5x12 Flat-Head Screw (2pcs)
Spacer
bracket & the lip bracket. Make sure clearance hole in spacer aligns with hole in mounting bracket.
4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32 screws and lockwashers.
6. Secure M5x12 screws holding mounting brackets to jamb.
4 7/8”
(124mm)
3 1/2”
(89mm)
4 1/8”
(105mm)
ESP1B + ESP2B
1 7/32”
(31mm)
3 3/8”
(86mm)
M5x12 Screw
Vertical Centerline
Note: The products are intended to be installed in accordance with the installation wiring diagram, mechanical assembly drawings provided with each product, the local authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70. When installed in fail secure mode, the local authority shall be consulted with regard to the use of possible panic hardware to allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and in such a location so as to not impair the operation of an emergency exit device or panic hardware mounted on the door.
1 7/32”
(31mm)
1 7/32”
(31mm)
3 3/8”
(86mm)
3 3/8”
(86mm)
5 11/16”
(144mm)
(155mm)
(200mm)
6 3/8”
(168mm)
7 3/8”
(187mm)
(173mm)
6 1/8”
ESP3B
7 7/8”
6 7/8”
Page 2 of 3
1 3/8”
(36mm)
ESP4B
Page 3
CX-ED2071 Electric Strike
5. Connections
POWER 8/16V AC/DC
Red: Power in Red: Power in
A varistor is provided to protect/prevent strike from spikes. Connect varistor between input wires.
Note: The door strikes are to be powered via a class 2 power limit output from a control panel or power supply that is UL listed to UL Burglar Alarm/Access control standards.
Power
8/16V AC/DC
Pin
Varistor
Pin
Red
Red
6. Operation
How to modify fail-safe to fail-secure or vice versa.
(1). Loosen the screw as per the product diagram below.
(2). Rotate the set plate 180° and slide the plate until it is properly seated.
(3). Tighten the screw.
Fail Safe
Changing
7. Faceplates
INCLUDED IN PACKAGE
⁄”
(16mm)
4 ⁄”
(104mm)
4 ⁄”
(123mm)
ESP1B - ANSI Square
1 ¼”
(32mm)
3 ⁄”
(85mm)
¾”
Black Red Blue Green
(19mm)
Power
⁄”
(16mm)
6 ⁄”
(154mm)
6 ⁄”
(173mm)
ESP3B - Hollow Metal Door ESP4B - Wood Door ESP2B - Ansi Round
1 ¼”
(32mm)
3 ⁄”
(85mm)
1 ¾”
(44mm)
7 ⁄”
(200mm)
⁄”
(16mm)
7 ½”
(189mm)
Fail Secure
(85mm)
1 ⁄”
(36mm)
3 ⁄”
2 ¼”
(57mm)
ADDITIONAL FACEPLATE
⁄”
(16mm)
4 ⁄”
(104mm)
3 ⁄”
(85mm)
4 ⁄”
(123mm)
¾”
1 ¼”
(32mm)
(19mm)
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
www.camdencontrols.com Toll Free: 1.877.226.3369
Page 3 of 3
File: CX-ED2071 Designer Installation Instructions.indd R2 Revision: 01/06/2018 Part No.: 40-82B210
Loading...