Camden Door Controls CX-DA400, CX-DA401 Specsheet

ELECTRIFIED LOCKS,
ELECTRIFIED LOCKS, RELAYS & TIMERS
RELAYS & TIMERS
CX-DA400 SERIES
DOOR MONITOR ALARM
FEATURES
CX-DA400
• STAND ALONE OPERATION OR INTERFACE WITH ACCESS CONTROL SYSTEM
• HEAVY DUTY STAINLESS STEEL FACEPLATE
• 12-24 V AC/DC
• ADJUSTABLE ALARM TIMING AND ALARM DELAY
• SELECTABLE ’HIGH’ OR ’LOW’ LEVEL SOUNDER
• RESET/BYPASS KEY SWITCH AND REMOTE INPUT
• VISUAL STATUS INDICATOR
• FUNCTIONS INCLUDE SHUNT RECYCLE, SHUNT DELAY, DOOR SUPERVISION AND INTRUSION DETECTION
• CX-DA401 INCLUDES TAMPER SWITCH FEATURE
DESCRIPTION
CX-DA-400 double gang door monitor alarm features a rugged stainless steel faceplate, 4 inputs, 5 outputs and has a range of adjustable time delay functions. It is designed to complement any access control system by providing prop/door held open and intrusion/door forced open detection, as well as local alarm and reset.
APPLICATION
Camden Door Controls CX-DA400 Series door monitor alarms are ideal for applications requiring local alarm notification of intrusion or door forced open, as well as door held open, either stand alone or as part of an access control system.
CX-DA400 Series door monitor alarms provide a loud 103 dB or 96 dB. audible warning with door supervision/status and a key switch alarm bypass. The voltage sensing feature monitors power on an electric lock, recognizing a change in voltage as a valid user.
Inputs include N/O or N/C Alarm Shunt, N/C Door Contact, N/O Remote Reset/ Bypass and Voltage Sense Shunt. Outputs include N/O and N/C Door Contact Status, N/O and N/C Door Prop Alarm Status, N/O and N/C Intrusion/Tamper Alarm Status, N/O and N/C Bypass/Key switch Status and Remote LED. There are three adjustable timers; auto reset 0 sec. -5 min. /manual, alarm delay 0 sec. – 5 min./infinite, and silent time 0 sec. – 90 min.
ARCHITECTS/ENGINEERS SPECIFICATION
Door monitor alarms to be used throughout the site/complex shall be Camden door monitor alarms, with brushed stainless steel faceplates, flush mounted on double gang electrical boxes. The door monitor alarms are to be designed for stand-alone operation or interconnected with an access control system. They shall have four Inputs, including N/O or N/C Alarm Shunt, N/C Door Contact, N/O Remote Reset/Bypass and Voltage Sense Shunt. The door monitor alarm shall also provide five outputs, including N/O and N/C Door Contact Status, N/O and N/C Door Prop Alarm Status, N/O and N/C Intrusion/Tamper Alarm Status, N/O and N/C Bypass/Key switch Status and Remote LED. The unit shall also have three adjustable timers; auto reset 0 sec. -5 min. /manual, alarm delay 0 sec. – 5 min./infinite, and silent time 0 sec. – 90 min. The audible sounder shall be selectable 103 dB or 96 dB.
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9) Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
ANNUNCIATORS TRANSFORMERS & POWER SUPPLIES RELAYS & TIMERS DOOR ALARMS MAGNETIC LOCKS CABINET LOCKS ELECTRIC STRIKES
ANNUNCIATORS TRANSFORMERS & POWER SUPPLIES RELAYS & TIMERS DOOR ALARMS MAGNETIC LOCKS CABINET LOCKS ELECTRIC STRIKES
DOOR MONITOR ALARM
SPECIFICATIONS
VOLTAGE: 12-24V AC/DC
CURRENT DRAW: 250 MA
INPUT: N/O OR N/C ALARM SHUNT
N/C DOOR CONTACT N/O REMOTE RESET/BYPASS VOLTAGE SENSE SHUNT
OUTPUT: N/O AND N/C DOOR CONTACT STATUS N/O AND N/C DOOR PROP ALARM STATUS N/O AND N/C INTRUSION/TAMPER ALARM STATUS N/O AND N/C BYPASS/KEY SWITCH STATUS REMOTE LED
CONTACT RATING: FORM ’C’, 1 AMP
TIME DELAY: AUTO RESET: 0 SEC. -5 MIN. /MANUAL
ALARM DELAY: 0 SEC. – 5 MIN./INFINITE SILENT TIME: 0 SEC. – 90 MIN.
SOUNDER: HIGH – 103 DB@ 3 FT.
LOW – 96 DB@ 3 FT.
DIMENSIONS: 4 1/2”H x 4 1/2”W x 2 1/2”D (114mm x 114mm x 63mm)
ORDERING INFORMATION
CX-DA400: DOOR ALARM WITH RELAYS, TIMERS, RESET KEY, DOUBLE GANG, 12-24V AC/DC
CX-DA401: DOOR ALARM, WITH RELAYS, TIMERS, RESET KEY AND TAMPER, DOUBLE GANG, 12-24V AC/DC
11
"
[17mm]
16
"
1
4
2
[114mm]
1
4
2
"
[114mm]
2
1
"
[63mm]
2
"
3
[86mm]
3
8
"
1
1
16
(ON=NORMALLY ENERGIZED) VOLTAGE SENSE MODE
SUPERVISION ENABLE DOOR
[27mm]
7
2
16
[62mm]
"
SELECT
SELECT
SELECT
SHUNT DELAY 0
SHUNT DELAY TIME
SHUNT RECYCLE ENABLE
RESERVED
DELAY ALARM
INTRUSION DETECT ENABLE
SHUNT CONTACT MODE (ON=NO)
COM
RESET AUTO
N/O
STATUS RELAY
N/C
BYPASS/KEY
COM
RELAY
ALARM
1713 14 1615 2218 19 2120 23 24
N/O
& TAMPER INTRUSION
N/C
COM RELAY ALARM
N/O
DOOR PROP
N/C
COM RELAY
STATUS
N/O DOOR
N/C
CX-DA400
HORN VOLUME
(ON=HIGH)
EXTENDED TIME
TIME
SILENT
20 SEC
CAMDENCONTROLS.COM
10 SEC
12-24 VAC/VDC POWER SUPPLY
5 SEC
RESET/BYPASS N/O REMOTE
0 SEC
CONTACT N/C DOOR
LED RED OUT
LED GREEN OUT
SHUNT DELAY 1
VOLTAGE SENSE +
VOLTAGE SENSE -
SHUNT
2 127 10 118 95 63 4
CONTACT DRY
1
FRONT VIEW BACK VIEWSIDE VIEW