Camden Door Controls CX-DA400, CX-DA401 Installation Instructions

CX-DA400
Door Prop Alarm
Installation Instructions
CONTENTS
CX-DA400
COMPONENT LOCATION DIAGRAM
OUTPUTS
• Remote LED - (located on TS-1) Output for a remote Bi-color LED, output follows LED on Face Plate.
• Door Status Relay - follows the Door Contact Input, regardless of alarm or bypass condition.
• Door Prop Alarm Relay - changes state during a Door Prop (Door Held) Alarm condition.
• Intrusion & Tamper Alarm Relay - changes state during an Intrusion or Tamper Alarm condition.
• Bypass/Key Switch Status Relay - follows Bypass and Key inputs.
Output contacts change state when power is lost.
DESCRIPTION
OTHER FEATURES
Shunt Recycle - See Step 3. Pg. 4
Door Supervision - See Step 1. Pg. 3
Intrusion Detect - See Step 2. Pg. 3
Loud Horn Volume - See Step 7. Pg. 5
Extended Silent Time - See Step 4. Pg. 4
Shunt Delay Timer - See Step 4 . Pg. 4
INPUTS
The inputs are located on Terminal Strip –1 and include:
• Dry Contact Shunt - a N/O or N/C Dry Contact, selected using Shunt Contact Mode Jumper 3. See Step 3. Pg. 4
• Voltage Sense - Monitors the power wires on an electric lock (i.e.: Mag-lock or Door Strike). Senses change in voltage as valid user. See Step 3. Pg. 4
• Door Contact - a Closed Loop (N/C) Dry Contact which opens when the monitored door opens. See Step 1. Pg. 3
• Bypass - Connect to a N/O Dry Contact from a remote location to bypass the unit. See Step 7 Pg. 5
• Power - 12 to 24 VAC/DC @ 250 mA. The terminals are not polarity sensitive. See Step 5. Pg. 4
JUMPER CONFIGURES
1 Door Supervision (Part of Tamper circuit) TS1-7&8 Door Input
2 Voltage Sense Mode (Senses Lock Voltage as Valid User Input) TS1-3&4 Voltage Sense Input
3 Shunt Contact Mode (Senses Dry Contact as Valid User Input) TS1-1&2 Shunt Contact Input
4 Intrusion Detect Enable (Explained on reverse) Intrusion or Free Access selection
5 Shunt Recycle Enable (Explained on reverse) Shunt Recycle feature selection
6 RESERVED (Factory Diagnostic) Factory Use Only Leave Jumper OFF
7 & 8 Shunt Delay Timer (Set same as Lock Time) Access Time prior to opening door
9 Extended Time Select Ext. Silent Time 3-90 Min.
10 Horn Volume Select 96db or 103db
Page 1 of 6
CX-DA400 Door Prop Alarm Installation Instructions
TIMERS
• SilentTime - “Open Door” Time - 0-2.5 min. in standard mode, 3 - 90 min. in Extended mode (selected by Jumper 9).
• AlarmDelay - “Warning” Time - 0-5 min. and “Innite.” Local
Beeping Warning Audible sounds during this time.
• AutoReset - “Alarm” Time - 0-5 min. and Manual Reset. Constant Alarm Audible sounds during this time.
• ShuntDelay - Valid Access Time prior to reset if Door is unopened. 0, 5, 10, or 20 seconds (set with Jumpers 7 & 8).
TIMER SETTING TABLE
SIDE VIEW
SET
0
1
2
3
4
5
6
7
SILENT TIME
SELECT
(Extended Silent Time Jumper)
NORMAL
Jumper OFF
0 Sec 3 Min 0 Sec 0 Sec
3 Sec 3.5 Min 3 Sec 3 Sec
5 Sec 4 Min 5 Sec 5 Sec
7 Sec 4.5 Min 7 Sec 7 Sec
10 Sec 5 Min 10 Sec 10 Sec
12 Sec 6 Min 12 Sec 12 Sec
15 Sec 7 Min 15 Sec 15 Sec
20 Sec 8 Min 20 Sec 20 Sec
EXTENDED
Jumper ON
ALARM
DELAY
TIME
SELECT
AUTO
RESET
TIME
SELECT
TAMPER CIRCUIT- Alarm is not reset with key.
(CX-DA401 only)
• TAMPER SWITCH - Switch is located on stand-off under spring steel actuator. (Cut cable tie to Enable switch)
• DOOR SUPERVISION - Enable with Jumper 1. Requires resistors on Door Switch. (Schematic on Step 1 Pg.3)
OPERATION
VALID ACCESS / PROPPED DOOR OPERATION
ARMED STATE - Red LED (Green if Intrusion Detect is Off) VALID USER INPUT - Shunt or Voltage Sense Input
LED - Changes to Green DOOR - Opened by user, Silent Timer begins DOOR - Closed by user, Returns to Armed State, or
- SILENT TIME TIMER - expires, then AUDIBLE WARNING - Beeps to alert user locally LED - Flashes Green DOOR - Closed by user, returns to Armed State, or*
- SHUNT RECYCLE - 2nd Valid User Input (*if enabled) SILENT TIME RESET - Silent Timer begins again
DOOR HELD/PROPPED - Alarm Delay Times out
LED - Flashes Red AUDIBLE - Constant tone, Auto Reset (AR) Timer begins OUTPUT - Door Prop Alarm relay toggles
DOOR CLOSED - After Door Prop Alarm exists
AUDIBLE - On until Auto Reset (AR) Time expires LED - Flashes Red for AR Time OUTPUT - Relay held for duration of AR Time
INTRUSION OPERATION
ARMED STATE - Red LED
DOOR Opened by invalid entry LED - Flashes Red AUDIBLE - Constant tone, Auto Reset (AR) Timer begins OUTPUT - Intrusion/Tamper Alarm relay toggles
- DOOR CLOSED
LED - Flashes for duration of AR Time AUDIBLE - Continues for duration of AR Time OUTPUT - Changed for duration of AR Time
- REARM - After AR time expires OR by Manual reset LED - Red (Armed State)
8
9
A
B
C
D
E
F
25 Sec 9 Min 30 Sec 30 Sec
30 Sec 10 Min 45 Sec 45 Sec
35 Sec 20 Min 1 Min 1 Min
45 Sec 30 Min 2 Min 2 Min
1 Min 40 Min 3 Min 3 Min
1.5 Min 50 Min 4 Min 4 Min
2 Min 60 Min 5 Min 5 Min
2.5 Min 90 Min INFINITE MANUAL
TAMPER OPERATION (CX-DA401 only)
ARMED STATE - Red LED (Door Supervision Enabled)
- TAMPER (Door circuit open/shorted, or if unit is
removed from wall) LED - Flashing Red AUDIBLE - Constant tone OUTPUT - Intrusion/Tamper Alarm relay toggles
- RESET - Door normal, and Tamper switch closed LED - Red (Armed State)
Page 2 of 6
CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
CX-DA400 Door Prop Alarm Installation Instructions
STEP BY STEP INSTRUCTIONS FOR EASY CONFIGURATION
THE DEFAULT SETUP IS FOR ACCESS CONTROLLED, AND EMERGENCY EXIT APPLICATIONS.
This unit may be connected to power and a closed-loop Door Input and be ready to work immediately for the Default application.
A Voltage Sense input used with a Mag-Lock, and/or a N/C Dry Contact Shunt input will require additional jumper conguration
(J2 and/or J3 respectively) and is covered in Step 3 Pg. 4.
• The unit is easily congured for a stand-alone Door Prop application by removing the Intrusion Detection jumper.
(LED will always be Green when Intrusion Detection is disabled.)
TIMER SETTING DEFAULTS: (Step 4 Pg.4)
Silent Time 5 seconds;
Alarm Delay Time 5 seconds
Auto Reset Time 5 seconds
Shunt Delay 20 seconds
See text for Feature Description and Setup info.
TERMS USED IN THIS INSTRUCTION
N/C DOOR CONTACT - is a “closed-loop” circuit which goes open
when the door is opened.
SHUNT INPUT - is a dry contact Valid User Input provided by an Access Control System or a PIR / REX device.
DMA - Door Management Alarm (i.e.: CX-DA400)
Normally Energized - in reference to a Mag-Lock or other locking
device where power is removed to unlock.
Normally De-energized - in reference to a Door Strike or other locking device where power is applied to unlock.
CX-DA400
Figure 1
• Tamper Alarm (cannot be reset or bypassed) A) To Enable feature cut cable tie on Tamper Switch located on standoff (Component Location on reverse. (CX-DA401 only)
INTRUSION DETECTION
2
A) Jumper 4 is ON for Access Control and Emergency Exit Only applications. B) Jumper 4 is OFF for Door Prop/Held applications without Access Control.
NOTE: If OFF, LED is Green except during a Door Prop Alarm. If OFF, Go to Step 4-Timer Settings. (Skip Step 3)
1
DOOR SUPERVISION, AND TAMPER
Connect N/C Door Contact to TS1 7&8.
If resistors are installed for Door Supervision:
A) place Jumper 1 ON and put resistors at door switch as shown in Figure 1. B) If unused, leave Jumper OFF and use a closed-loop Door Switch circuit.
ACCESS CONTROL
3
• VOLTAGE SENSE monitors Lock Power as “Valid User” input on TS1 (3&4) A) If unused, Jumper 2 must be OFF. B) If used, select: Normally Energized (Jumper 2 ON); or, Normally De-Energized (Jumper 2 OFF)
VOLTAGE SENSE EXPLAINED - This
input samples the voltage to a Mag Lock (J2 ON) or a Door Strike* (J2 OFF) and accepts a change in voltage as a valid user input. *Normally de-energized.
• SHUNT INPUT detects a Dry Contact input for each valid access. TS1 (1&2)
A) If unused, Jumper 3 must be ON B) If used, Select: Jumper 3 ON for N/O input; or Jumper 3 OFF for N/C input
Page 3 of 6
• SHUNT RECYCLE (see description below) A) Jumper 5 is ON B) Jumper 5 is OFF
SHUNT INPUT EXPLAINED - This
input from a PIR or Access Control system provides user validation.
CX-DA400 Door Prop Alarm Installation Instructions
• SILENT TIME SELECT begins when the door is opened by a valid user. (see Timer Setting Table on reverse)
A) Timer has two ranges selected with Jumper 9;
Normal - 0 seconds to 2.5 minutes (Jumper OFF)
Extended - 3 minutes to 90 minutes (Jumper ON)
B) After selecting appropriate range, turn dial to SET # for the Silent Time period desired for your application.
• ALARM DELAY SELECT begins on the expiration of the Silent Timer. Warning Alarm sounds locally to alert user.
A) Turn dial to SET # on table (see reverse) for the time you want the Warning (beeping) alarm to sound (prior to triggering the Door Prop Alarm Horn and Relay).
• AUTO RESET TIME SELECT is the minimum time the Horn, LED and Relays are on following an alarm condition.
NOTE: Alarm will continue for as long as the door is open
A) Turn the dial to SET Timer (0 seconds to 5 minutes, or Manual).
POWER
5
• POWER - Connect 12-24 VAC/DC to TS1 11&12. Not polarity sensitive.
SHUNT RECYCLE EXPLAINED -
When Shunt Recycle is Enabled (ON), a Shunt Contact or Voltage Sense Input during the Alarm Delay warning period (beeping) will reset the Silent Time
Timer. Shunt Recycle gives the User the ability to Hold the door indenitely by
repeating a valid input during each Alarm Delay warning.
When disabled, only a Key or Bypass input will reset the DMA.
TIMER SETTINGS SEE TABLE ON REVERSE
4
The SHUNT DELAY TIMER begins after a Valid User input (prior to door being opened) and if door is not opened the DMA will reset when timer expires. Cancels upon door opening.
A) Shunt Delay works only with Intrusion Detection enabled. B) See table on Back Plate for Jumper 7&8 setting detail.
OUTPUTS (FORM-C)
6
• DOOR STATUS RELAY TS2-22,23,24 changes state when the Door Input changes. Used to monitor changes in Door Contact status.
• DOOR PROP ALARM RELAY TS2-19,20,21 changes state when a door is held open beyond the Silent and Alarm Delay time, combined.
• FORCED DOOR/TAMPER ALARM RELAY
TS2-16,17,18 changes state when a door is forced or a tamper condition exists (Door Supervision/Tamper Switch).
• BYPASS/KEY SWITCH STATUS RELAY
TS2-13,14,15 changes state during Bypass (TS1 9&10) and Key Switch Inputs. Used to monitor for changes in Bypass status.
Page 4 of 6
ADDITIONAL OUTPUT INFORMATION
Each of the Output functions offers the availability of monitoring a Normally Open or a Normally Closed Dry contact.
Each contact’s state will change to follow the status of the monitored function.
To combine multiple outputs, connect N/O contacts in parallel, or N/C contacts in series. See diagrams at right. The use of any/all Outputs is optional.
If power is removed from the CX-DA400, each contact in it’s normal state (powered), will change state. Example: Door Status will appear as if the door has been opened; Alarm and Bypass contacts will appear as if an alarm or bypass condition exists.
ADDITIONAL FEATURES
7
SEE COMPONENT LOCATION DIAGRAM ON PAGE 2
BYPASS TS1
(9&10) input, to N/O contact to remotely Bypass or Reset the unit.
CX-DA400 Door Prop Alarm Installation Instructions
REMOTE LED
to TS1 (5&6).
HORN VOLUME -
Jumper 10 is used to set the volume of the sounder. ON = 103db OFF = 96db
TROUBLE SHOOTING TIPS
• Horn won’t Reset - Verify Tamper Switch is closed; Verify Door Supervision Jumper is correct for application; Check Door Contact Resistors are installed as per Step 1 if Door Supervision is enabled.
• LED always Green - Normal condition when Jumper 4 is OFF; Verify Shunt Contact & Voltage Sense jumpers are correct for your application; Verify Key Switch is Vertical and Bypass Input is open.
• Alarm when Door Opens - Verify that SO&S1 Jumpers and Silent Time are set greater than 0 sec.; Verify Intrusion Jumper is set correctly for application.
• Clicking Output Relays - Verify Jumper 6 (Reserved) is OFF.
ELECTRICAL SPECIFICATIONS
VOLTS AMPS N/O N/C
Power
Voltage Sense
Shunt Input
Bypass Input
Door Input
Output Relays
12-24 VAC/DC 250mA
12-24 VAC/DC 15mA
Dry Contact
Dry Contact
Dry Contact
Dry Contact
1 Amp@
30 VDC
N/A
Jumper Select
✔ ✔
MECHANICAL SPECIFICATIONS
• The CX-DA400 mounts ush in a 2.5” (63 mm) deep, 2-Gang
electrical box.
Page 5 of 6
TECHNICAL DRAWING
C
C
D
D
B
B
E
E
A
A
F
F
9
9
0
0
8
8
1
1
7
7
2
2
6
6
3
3
5
5
4
4
SEE DETAIL B
C
D
B
E
A
F
9
0
8
1
7
2
6
3
5
4
CX-DA400 Door Prop Alarm Installation Instructions
C
C
C
D
D
D
B
E
A
F
9
0
8
1
7
2
6
3
5
4
DETAIL B
A
9
8
7
6
SET TO #2
B
3X
B
E
E
A
F
F
9
0
0
8
1
1
7
2
2
6
3
3
5
5
4
4
1
4
" [114mm]
2
1
2
2
" [63mm]
1
4
" [114mm]
2
11
" [17mm]
16
3
" [86mm]
3
8
1
" [27mm]
1
16
SELECT
HORN VOLUME
(ON=HIGH)
EXTENDED TIME
TIME
SILENT
20 SEC
CAMDENCONTROLS.COM
10 SEC
12-24 VAC/VDC POWER SUPPLY
5 SEC
RESET/BYPASS N/O REMOTE
0 SEC
CONTACT N/C DOOR
LED RED OUT
LED GREEN OUT
VOLTAGE SENSE +
VOLTAGE SENSE -
SHUNT
2 127 10 118 95 63 4
CONTACT DRY
1
SELECT
SELECT
COM
RESET
DELAY
AUTO
ALARM
SHUNT CONTACT MODE (ON=NO)
INTRUSION DETECT ENABLE
SHUNT RECYCLE ENABLE
RELAY
ALARM
RELAY ALARM
RELAY STATUS DOOR
STATUS RELAY
BYPASS/KEY
& TAMPER INTRUSION
DOOR PROP
N/O
N/C
COM
1713 14 1615 2218 19 2120 23 24
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
(ON=NORMALLY ENERGIZED) VOLTAGE SENSE MODE
SUPERVISION ENABLE DOOR
CX-DA400
7
2
16
" [62mm]
SHUNT DELAY TIME
SHUNT DELAY 0
SHUNT DELAY 1
RESERVED
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
www.camdencontrols.com Toll Free: 1.877.226.3369
File: CX-DA400 Installation Instructions.indd- Rev1 Revised: June 9th, 2014 Part No: 40-82B157
Page 6 of 6
Loading...