DOOR ACTIVATION DEVICES
ACCESSORIES
CM-PG1
CM-PG1, PG2, PG3 AND PG4
DOOR PRESSURE GAUGES
AN ESSENTIAL TOOL FOR:
• AUTOMATIC DOOR SALESPEOPLE, AND INSTALLERS
• OVERHEAD DOOR INSTALLERS
MEET ADA REQUIREMENTS:
A. The American with Disabilities Act and Canadian Regulations requires that both interior and exterior doors of a building be wheelchair accessible.
B. Door Opening Force (4.13.11 ADAAG)
- Exterior hinged doors: (reserved)
- Interior hinged doors: 5 lbf. (22.2N)
- Sliding or folding doors: 5 lbf. (22.2N)
Automatic/Power Assisted Doors: (4.13.12) Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbs. (66.6N) to stop door movement. If a power-assisted door is used, its door-opening force shall comply with 4.13.11 and its closing force shall conform to the requirements in ANSI A156.19 (1984).
• ENGINEERS, ARCHITECTS, AND CONTRACTORS
• BUILDING OWNERS, AND INSPECTORS
MODEL: CM-PG1
• 0-7 lbs. force range
• This light duty gauge can be used in determining the lower limitations of interior and exterior door opening/ closing forces.
MODEL: CM-PG3
• 10-50 lbs. force range
• This robust unit is used to measure ”door opening” and ”sliding-door” breakout panel force.
MODEL: CM-PG2
• 0-35 lbs. force range
• This unit is larger and more robust. It is suitable for measuring the force of full-size, normal speed door operators as well as measuring the closing force of ”overhead doors” and ”elevator doors”.
MODEL: CM-PG4
• 10-66 lbs. force range
• This robust unit is used to measure ”door opening” and ”sliding-door” breakout panel force.
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9) Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
ACCESSORIES KEYPADS SPECIAL PURPOSE SWITCHES HANDS-FREE SWITCHES RF CONTROLS MOUNTING OPTIONS PUSH BUTTONS KEY SWITCHES
DOOR PRESSURE GAUGES
OPERATING INSTRUCTIONS:
A- Set ”o” ring on zero, down against the instruments flange, or on the desired
maximum force.
B- Holding the instrument firmly, either push or pull a given door at a point
approximately handle-high and 30 inches toward the handle from the door's hinges.
C- Read the amount of force required to open/close the door on the plunger scale
closest to the bottom of the small ”o” ring.