Camden Door Controls CM-PG1, CM-PG2, CM-PG3, CM-PG4 User Manual

Door Activation Devices
INSTALLATION INSTRUCTIONS
1. AN ESSENTIAL TOOL FOR:
• Automatic door salespeople, and installers
• Overhead door installers
• Engineers, architects, and contractors
• Building owners, and inspectors)
2. MEET ADA REQUIREMENTS
A. The American with Disabilities Act and Canadian Regulations requires that both interior and exterior doors of a building be wheelchair accessible.
B. Door Opening Force (4.13.11 ADAAG)
• Exterior hinged doors: (reserved)
• Interior hinged doors: 5 lbf. (22.2N)
• Sliding or folding doors: 5 lbf. (22.2N)
Automatic/Power Assisted Doors: (4.13.12) Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbs. (66.6N) to stop door movement. If a power-assisted door is used, its door-opening force shall comply with 4.13.11 and its closing force shall conform to the requirements in ANSI A156.19 (1984).
Model: CM-PG1
• 0-7 lbs. force range
• This light duty gauge can be used in determining the lower limitations of interior and exterior door opening/closing forces.
Model: CM-PG2
• 0-35 lbs. force range
• This unit is larger and more robust. It is suitable for measuring the force of full-size, normal speed door operators as well as measuring the closing force of ”overhead doors” and ”elevator doors”
Model: CM-PG3
• 10-50 lbs. force range
• This robust unit is used to measure ”door opening” and ”sliding-door” breakout panel force.
Model: CM-PG4
• 10-66 lbs. force range
• This robust unit is used to measure ”door opening” and ”sliding-door” breakout panel force.
3. OPERATING INSTRUCTIONS
A. Set ”o” ring on zero, down against the instruments
ange, or on the desired maximum force.
B. Holding the instrument rmly, either push or pull a given
door at a point approximately handle-high and 30 inches toward the handle from the door’s hinges.
C. Read the amount of force required to open/close the door on the plunger scale closest to the bottom of the small ”o” ring.
Opening New Doors to Innovation, Quality and Support!
Call: 1.877.226.3369 / 905.366.3377 Visit: www.camdencontrols.com
Model: CM-PG1
Model: CM-PG3
Model: CM-PG2
Model: CM-PG4
File: CM-PG1 to 4 Manual_R2.indd Revision: 07/07/2015 Part No : 40-82B044
Page 1 of 1