THIS PACKAGE INCLUDES
(1) Foam Gasket
(1) O Ring
(1) Set of Labels
(1) LED Base
(1) Lens
(1) 2-28 x 5/16" Phillips locking screw
(2) Concrete wall plugs
1. DESCRIPTION
Camden CM-AF142SO Multi-color Dome Light, provides both visual and audible annunciation. It mounts to a standard single gang electrical box. The Superbright LED’s along with the wedged shaped lamp cover provides visible illumination from either end of a corridor. The integrated piezo buzzer with adjustable volume provides up to 93 dB at 1 metre (3 feet).
2. SPECIFICATIONS
Voltage
Illumination
Sounder
Current Rating
Dimensions (Body)
12/24V AC/DC
Superbright LED's
Piezo, 93 dB max. @ 1 metre (3 ft.)
70 mA Max for one color wire. Combining more than one color wire = 130 mA.
4 9/16" H x 2 15/16" W (115mm x 75mm)
(2) #6 x 3/4" self-tapping screws
(2) 6-32 x 3/4" screws
(4) Wire nuts
(2) 3/16" drywall plugs
4. WIRING
Camden CM-AF142SO Multi-color Dome Light is easily wired using the two of the four color coded wires supplied; Black (BLK), Red (RED), Green (GRN) and Blue (BLU). Using the BLK wire as common, selecting one of the three color wires to complete the circuit will determine the color of the Dome light. The black wire lead and any one of the color coded wires can be connected to either an AC or DC power source supplying 12 or 24 volts.
- Use black wire
-
+
for common
- Select red wire for red color
- Select green wire for green color
- Select blue wire for blue color
3. SOUND VOLUME ADJUST
Using a small Phillips screwdriver, gently turn the volume adjustment counter clock wise to reduce the volume and
clockwise to increase the volume.
12-24 AC/DC Power
Page 1 of 2
5. INSTALLATION
O Ring
Lens
Locking Screws
A S S
I S T A N C E
R E Q U
I R E D
Labels
Labels
CM-AF142SO mounts to a standard single gang electrical box.
CM-AF142SO Single Gang LED Dome Light with Sounder
INSTALLATION INSTRUCTIONS
CM-AF142SO
Base
Gasket
FLASH RATE: Increase or decrease the flash rate by gently turning the potentiometer with a small screwdriver.
Step 1
Place the gasket (supplied) between the base unit and the electrical box. Use the 6-32 screws to fasten the base to the electrical box.
Step 3
Install the lens by inserting the large bottom tab
rst. The top tabs
will snap in place with little effort.
Step 4
Install the Phillips locking screw into the bottom of the base.
Step 2
Insert the O ring gasket into the small channel in front of the base. The O Ring does not completely close around the base. You must leave a small opening at the bottom of the base.
Step 5
Apply the labels as required to the lens.
(115mm)
4-9/16”
2-15/16” (75mm)
Opening New Doors to Innovation, Quality and Support!
1-9/16”
(40mm)
3-1/16”
(77mm)
2-1/16” (53mm)
Call: 1.877.226.3369 / 905.366.3377 Visit: www.camdencontrols.com
3-1/4”
(83mm)
File: CM-AF142SO-Manual-R2.indd Revision: 04/07/2019 Part No.: 40-82B228