Camden Door Controls CM-57GR-1, CM-57GR-2, CM-57GR-2AL, CM-57GR-2AR, CM-57GR-3 Installation Instructions

...
Aura™ CM-57GR
Flush Mount Illuminated Enclosure
Installation Instructions
PACKAGE CONTENTS
1
CM-57
1
Green/Red Aura PCB
1
Dry wall Bracket
2
8-32 x 1 1/2” Screws
2
#6 x 3/8” Screws
Section 1
General Description
Camden Aura™, Model CM-57GR provide the Industry’s 1st “Changing State” illuminated switch enclosures.
They offer eld selectable green/red illumination, activated directly by the switch or remotely by a relay* such as our CX-33
or EMF-2, a time-clock or access control system.
User selectable features include a 3 Amp Form C relay, and piezo speaker for audible annunciation, as well as control over
the idle and active LED colours.
Another exclusive is the ability to plug in a TX-9 RF transmitter, thereby requiring only 2 conductors be run for power (& no batteries required) !!
The box is made of impact and ame resistant black ABS, and compatible with any Camden CM-41, CM-45, or CM-46 series
switch.
The illumination is provided by an array of super-bright and energy efcient LED’s, which can be powered by 12 or 24 volts AC/DC.
Setup
Switch Position Description
SPEAKER On to enable operation of
1
SW1
Colour selection is made with Switch SW2.
You rst chose the Idle colour – Red, or Green, or off, and then the Active colour – Red, or Green, or off.
Switch Position Description
SW2
If dipswitches 1 & 2 are both OFF, then no illumination will be present in idle state. Likewise, if both dipswitches 3 & 4 are both OFF, then no illumination will be present in the active state.
Once all dipswitches are set, proceed to Section 3 - Installation.
2
3
4 Not used
1 ON = Red LED when Idle.
2 ON = Green LED when Idle
3 ON = Red LED when Active
4 ON = Green LED when Active
the speaker with activation of the
push button
RELAY On to enable operation of the relay with activation of the push button
REMOTE / LOCAL On to enable LED
colour change from idle to Active with
press of the push button.
Section 2
Setup
Switch SW1 contains a bank of 4 dipswitches.
Dipswitch #1 turns the speaker on or off. Dipswitch #2 toggles
operation of the relay, and #3 allows you to choose whether the colour will be changed locally via the push switch, or remotely. (Dipswitch #4 is not used at this time)
*Note: The CX-22 Washroom relay may be used with the Aura™, however an isolating relay must be wired in parallel with the lock, and the relay’s dry contact output wired into the CM-57GR.
Page 1 of 5
Section 3
Installation
NOTE: If you will be including the optional Aura™ signage, follow that product’s installation instructions before installing Aura™.
1. Assemble the drywall clamp to the box as per diagram 1.
Determine the wire access location and drill hole of sufcient
size, or use center knock-out plug.
2. Using the template, cut a hole in the drywall. Pull the wiring
through the access hole and push the box through until the drywall clamp is on the back of the drywall. Tighten the 8-32 screws until the box is rmly mounted.
3. Remove circuit board from package and locate into the box (orientation - you should be able to read the writing next to the terminal strips and dip switches). Pull the wire through the hole in the centre of the circuit board, and then secure with the two small self-tapping screws (provided).
Aura™ CM-57GR Flush Mount Illuminated Enclosure Installation Instructions
CX-EL8000 & CX-EL8000L Electronic Cabinet Lock
4.a Wire as per diagram 2 (typical installation). Route the switch wiring through opaque diffuser panel, and install diffuser panel into box. It should t snuggly.
4.b If using a TX-9 transmitter to send the signal to an RX-91 or RX-92 Receiver, attach the transmitter and wire it before installing circuit board into the enclosure and tting diffuser. See Diagram 3.
5. Screw in two #6-32 Allen-head screws (provided with
switch) into the threaded center inserts, then attach wires
to switch and install switch over screws. Using the Allen
key (provided), locate the screws and tighten (by hand only).
6. Re-connect power and test for proper operation.
Section 4
Technical Data
Model CM-57GR
Dimensions 6 1/2” H x 6 1/2” W x 2” D
(165 mm x 165 mm x 51 mm)
Construction Flame-resistant black ABS (Insert – translucent ABS)
Finish Attractive pebble nish
Mounting 4 x #12 wood screws with anchors
Input Voltage 12 or 24V AC/DC
Output Voltage 3 Volts DC for TX-9 (only)
Current draw 150 mA (max)
Sounder 3200 ± 300 Hz @ 85 dB
Lumina Red: 14.8 lumens, 1600 mW; Green: 3.8 lumens, 330 mW,
Relay Contact 1 x Form C
Contact Rating 3A @ 30 VDC
Section 5
Warranty
Camden Door Controls guarantees the Aura™ (CM-57GR series) to be free from manufacturing defects for 3 years from date
of sale.
If, during the rst 3 years, the Aura™ fails to perform correctly, it may be returned to our factory where it will be repaired or replaced (at our discretion) without charge. Except as stated
herein, Camden extends no warranties expressed or implied regarding function, performance or service.
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
DISCOVER THE BEST IN DOOR ACTIVATING AND LOCKING PRODUCTS!
www.camdencontrols.com Toll Free: 1.877.226.3369
Page 2 of 5
File: CM-57GR Manual. indd Rev1
Revised: 15/07/2016
Part No: 40-82B197
TO OPEN
Drywall Clamp
CM-57 Box
STEP 1
Phillips Screws
2 x 8-32 x 1 1/2”
for drywall bracket
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
CAMDEN DOOR CONTROLS
CM-57GR Dimensional & Assembly Diagram
DRAWN BY: DGW DATE: 07/06/12 REVISED:
TM
IDL
ACT
RED
G/B
RED
G/B
COLOR SELECT
PCB
Green Aura
CM-57GR Dimensional & Assembly Diagram
Diffuser
ENABLE
CM-TX-9 Reserved For
LOC/REM
RELAY
SPEAKER
Pan head
2 x #6 x 3/8”
PCB to box
for mounting
Phillips Screws
SCALE: NONE
Allen Screws
2 x 6-32 x 1 1/2”
to box assembly
to mount the switch
DRAWING No: DRG-CM-57GR_01 FILE NAME: CM-57GR diagram 1.vsd
Page 3 of 5
CM-40
Push Plate
PUSH
L4W 2T7
Power terminals are not polarity sensive
Typical installaon shown
changes LED colour
acvaon change LED colour
LOCal dip on SW
REMOTE terminals
Mississauga, Ontario
5502 Timberlea Blvd.
Power & Relay
Terminal Strip
IDLE
G/B
RED
123
12 / 24 V
ACTIVE
RED
Wire Access Hole
AC / DC
G/B
4
Switch mounng holes (x2)
Off / On
CM-57GR Wiring Diagram (Typical)
Circuit Board Mount (x2)
N.C.
N.O.
COM
SW1 Dipswitch
Reserved for
RF Transmier
Lazerpoint TX-9
Pushbuon
Box mounng screw locaons
(hidden under circuit board) (x4)
NOT USED
RELAY
LOC / REM
4
2
3
Remote
Disable
CM-57 Enclosure
SPEAKER
On / Off
1
Diffuser Ring
sold separately )
All-Acve Switch
(
FILENAME: CM_57_GR Diagram 2.vsd
Camden Door Controls
CM-57GR Wiring Diagram (Typical)
DRAWING No: DRG-CM-57GR _02
SCALE: NONE DRAWN BY: DGW REVISED:04/04/13DATE: 07/06/12
SW2 Dipswitch
12 / 24 V
AC/DC
Power
Device
or Locking
Door operator
or Relay
Remote Switch
Page 4 of 5
ie - CX-33
.
, where remote device
, then set REMote /
. If it is desired to have switch
Switch
Disable
Remote
or EMF-2
Optional
2.
NOTES:
1.
.
1 to LOCAL , and do not wire to the
Off / On
Power terminals are not polarity sensive
This installaon is intended for
Cut the middle red lead to 1/4”
Cut both baery leads
switch lead to approximately
Strip the insulaon back on the
approximately 1/4”.
Turn over
and remove release paper
from double sided tape.Line up and carefully install TX
circuit board as shown above right
IDLE
G/B
RED
123
12 / 24 V
ACTIVE
RED
NOT USED
LOC / REM
SPEAKER
RELAY
4
AC / DC
G/B
4
N.C.
N.O.
COM
TX-9
CAMDEN CM-TX-9
Remote
LAZERPOINT
On / Off
1
2
3
Disable
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
FILENAME: CM_57 GR Diagram 3.vsd
Camden Door Controls
Wiring Diagram for CM-57GR & TX-9
CM-57GR & TX-9
Power
AC/DC
12 / 24 V
-
+
-
-
+
+
TX-9
CAMDEN CM-TX-9
LAZERPOINT
2“
<< Cut this lead to ¼”
DRAWING No : DRG-CM-57GR _03
Diffuser
Connect the 3 wires from the TX-9 to
the circuit board exactly as shown.
The middle red wire that was cut short
STEP 3
is not used.
Install circuit board in box , & connect the
STEP 4
2 power wires as shown.
Set dipswitches for desired operaon.
Install diffuser, connect push switch wires to
terminal strip, then install switch.
Test for proper operaon.
Switch
SCALE: NONE DRAWN BY: DGW REVISED:04/22/13DATE: 07/06/12
.
2-wire retrofit
3 long ends to
STEP 1
as it is not used.
2” long.
, and the remaining
STEP 2
,
-9 on Aura
NOTES:
1. 12/24
applicaons.
2.
Page 5 of 5