INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
1- CM-55i 1- Red / Green / Blue Aura PCB
2- Dry Wall Bracket 2- 8-32 x 1-1/2" Screws 2- #6 x 3/8" Screws
1. GENERAL DESCRIPTION
Camden Aura™, Model CM-55i provide the Industry’s 1st “Changing State” illuminated switch enclosures.
our CX-33 or EMF-2, a time-clock or access control system.
User selectable features include a 3 Amp Form C relay, and piezo speaker for audible annunciation, as well as control
over the idle and active LED colours. Another exclusive is the
ability to plug in a TX-9 RF transmitter, thereby requiring only 2 conductors be run for power (no batteries required).
The box is made of impact and ame resistant black ABS, and compatible with any Camden CM-41, CM-45, or CM-46 series switch. The illumination is provided by an array of super-bright and energy ecient LED’s, which can be powered by 12 or 24 volts AC/DC.
2. SPECIFICATIONS
3. SETUP
Switch SW1 contains a bank of 3 dipswitches.
Dipswitch # 3 turns the speaker on or off. Dipswitch # 2 toggles operation of the relay, and # 1 allows you to choose whether the color will be changed locally via the push switch or remotely.
* NOTE: The CX-12 Plus Multi-Function Relay may be used with the Aura™, however an isolating relay must be wired in parallel with the lock, and the relay’s dry contact output wired into the CM-55i.
Switch Position Description
REMOTE / LOCAL On to enable
1
SW1
Color selection is made with Switches SW2 and SW3. SW2 determines the Active color and SW3 determines the Idle color.
2
3
Setting the IDLE Color (SW2)
LED color change from idle to Active
with press of the push button.
RELAY On to enable operation of the relay with activation of the push button.
SPEAKER On to enable operation of
the speaker with activation of the
push button.
Input Voltage 12 or 24V AC/DC
Output Voltage 3 Volts DC for TX-9 (only)
Current draw 250 mA @ 12VDC / 110 mA @ 24 VDC
Contact Rating 3A @ 30 VDC
Lumina Red 14.8 lumens, 1600 mW
Lumina Green 3.8 lumens, 330 mW
Sounder 3200 ± 300 Hz @ 85 dB
Relay Contact 1 x Form C
Mounting 4 x #12 wood screws with anchors
Construction
Finish Attractive pebble nish
Dimensions
Flame-resistant black ABS (Insert–translucent ABS)
6-1/2” H x 6-1/2” W x 2” D (165mm x 165mm x 51mm)
Switch Position Description
1 ON = Red LED when IDLE
SW2
2 ON = Green LED when IDLE
3 ON = Blue LED when IDLE
Setting the Active Color (SW3)
Switch Position Description
1 ON = Red LED when Active
SW3
NOTE: If all DIP switches are in the OFF position, there will be no color illuminated. This allows for no Idle color or no Active color.
Once all DIP switches are set, proceed to Section 4 – Installation.
2 ON = Green LED when Active
3 ON = Blue LED when Active
Page 1 of 5
CM-55i FLUSH MOUNT ILLUMINATED ENCLOSURE
INSTALLATION INSTRUCTIONS
4. INSTALLATION
NOTE: If you will be including the optional Aura™ signage, follow that product’s installation instructions before installing Aura™
1. Assemble the drywall clamp to the box as per diagram. Determine the wire access location and drill hole of sucient
size, or use center knock-out plug.
2. Using the template, cut a hole in the drywall. Pull the wiring
through the access hole and push the box through until the drywall clamp is on the back of the drywall. Tighten the 8-32 screws until the box is rmly mounted.
3. Remove circuit board from package and locate into the box. Pull the wire through the hole in centre of circuit board, and then secure with the two small self-tapping screws (provided).
4a. Wire as per diagram 2 (typical installation). Route the switch
wiring through opaque diffuser panel, and install diffuser panel into box. It should t snuggly.
4b. If using a TX-9 transmitter to send the signal to an
RX-91 or RX-92 Receiver, attach the transmitter and wire it before installing circuit board into the enclosure and tting
diffuser. See Diagram 3.
5. Screw in two #6-32 Allen-head screws (provided with switch) into the threaded center inserts, then attach wires to switch
and install switch over screws. Using the Allen key (provided), locate the screws and tighten (by hand only).
6. Re-connect power and test for proper operation.
5. WARRANTY
Camden Door Controls guarantees the Aura™ (CM-55i series) to be free from manufacturing defects for 3 years from date
of sale.
If, during the rst 3 years, the Aura™ fails to perform correctly, it may be returned to our factory where it will be repaired or replaced (at our discretion) without charge. Except as stated
herein, Camden extends no warranties expressed or implied regarding function, performance or service.
Page 2 of 5
Drywall Clamp
CM-55i FLUSH MOUNT ILLUMINATED ENCLOSURE
INSTALLATION INSTRUCTIONS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
STEP 1
CM-55i Box
PCB
TM
Aura
CM-55i Dimensional & Assembly Diagram
Diffuser
drywall bracket
2 x 8-32 x 1-1/2”
Phillips Screws for
STEP 2
2 x #6 x 3/8”
Pan head Phillips Screws
for mounting PCB to box
CAMDEN DOOR CONTROLS
DRAWN BY: DGW DATE: 04/26/17 REVISED:
CM-55i Dimensional & Assembly Diagram
DRAWING No: DRG-CM-55i_01 FILE NAME: CM-55i diagram 1.vsd
SCALE: NONE
CM-45 Push Plate
STEP 3
2 x 6-32 x 1-1/2”
switch to box assembly
Allen Screws to mount the
PUSH
TO OPEN
Page 3 of 5
CM-55i FLUSH MOUNT ILLUMINATED ENCLOSURE
INSTALLATION INSTRUCTIONS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Switch mounting holes (x2)
SPEAKER RELAY REM/LOC
ON DP
CM-55i Wiring Diagram (Typical)
IDLE COL
1 2 3
ON DP
Circuit Board Mount (x 2)
NC COM NO PWR AC/DC
-REM + -PBTN + EN RF/TX -
ACTIVE
BLUE
GREEN
RED
1 2 3
Power and Relay Terminal Strip
PWR +
ENABLE
1 2 3
ON DP
CM-55 Enclosure
Box mounting screw locations
Diffuser Ring
All-Active Switch (sold separately)
CAMDEN DOOR CONTROLS
CM-55i Wiring Diagram (Typical)
DRAWN BY: DGW DATE: 04/26/17 REVISED:
DRAWING No: DRG-CM-55i_02 FILE NAME: CM_55i Diagram2.vsd
SCALE: NONE
Page 4 of 5
12 / 24 V
Power
AC/DC
Door
Operator
SW3 Dipswitch
Device
or Locking
SW2 Dipswitch
SW1 Dipswitch
Wire Access Hole
or Relay
Remote Switch
(ie. CX-33 or EMF-2)
NOTES:
1. Power terminals are not polarity sensitive
2. Typical installation shown, where remote device changes
LED color. If it is desired to have switch activation change
LED color, set REMote/LOCal dip on SW1 to LOCAL and do
not wire to the REMOTE terminals.
CM-55i FLUSH MOUNT ILLUMINATED ENCLOSURE
INSTALLATION INSTRUCTIONS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
NC COM NO PWR AC/DC
PWR +
-REM + -PBTN + EN RF/TX -
CM-55i & TX-9
IDLE COL
ON DP
ACTIVE
1 2 3
1 2 3
ON DP
CAMDEN
LAZERPOINT
BLUE
GREEN
RED
CM-TX-9
Diffuser
Switch
CAMDEN DOOR CONTROLS
Wiring Diagram for CM-55i & TX-9
DRAWN BY: DGW DATE: 04/26/17 REVISED:
DRAWING No: DRG-CM-55i_03 FILE NAME: CM_55i Diagram3.vsd
SCALE: NONE
12 / 24 V
Power
AC/DC
+
-
ENABLE
SPEAKER RELAY REM/LOC
1 2 3
ON DP
-
-
+
+
2”
<< Cut this lead to ¼”
TX-9
STEP 1:
Cut the middle red lead to 1/4” as it is not used. Cut
both battery leads and the remaining switch lead to
approximately 2” long. Strip the insulation back on
the 3 long ends to approximately 1/4”.
Opening New Doors to Innovation, Quality and Support!
CAMDEN CM-TX-9
LAZERPOINT
Call: 1.877.226.3369 / 905.366.3377 Visit: www.camdencontrols.com
STEP 2:
Turn over and remove release
paper from double-sided
tape. Line up and carefully
install TX-9 on back surface of
mounting box.
STEP 3:
STEP 4:
Install circuit board in box and connect the 2 power wires
as shown. Set dipswitches for desired operation. Install
diffuser and connect push switch wires to terminal strip
Connect the 3 wires from the TX-9 to the circuit board
exactly as shown. The middle red wire that was cut short
is not used.
File: CM-55i Manual_R3.indd Rev.: 06/01/20 Part No.: #40-82B208
then install switch. Test for proper operation.
NOTES:
1. 12/24 Power terminals are not polarity sensitive.
2. This installation is intended for 2-wire retrofit applications.
Page 5 of 5