Camden Door Controls CM-55i-1, CM-55i-2, CM-55i-2AL, CM-55i-2AR, CM-55i-3 Installation Instructions

...
Aura™ CM-55i
Flush Mount Illuminated Enclosure
Installation Instructions
PACKAGE CONTENTS
1
CM-55i
1
Blue/Green/Red Aura PCB
1
Dry wall Bracket
2
8-32 x 1 1/2” Screws
2
#6 x 3/8” Screws
Section 1
General Description
Camden Aura™, Model CM-55i provide the Industry’s 1st “Changing State” illuminated switch enclosures.
They offer eld selectable blue/green/red illumination, activated directly by the switch or remotely by a relay*
such as our CX-33 or EMF-2, a time-clock or access control system.
User selectable features include a 3 Amp Form C relay, and piezo speaker for audible annunciation, as well as control
over the idle and active LED colours.
Another exclusive is the ability to plug in a TX-9 RF transmitter, thereby requiring only 2 conductors be run for power (& no batteries required) !!
The box is made of impact and ame resistant black ABS, and compatible with any Camden CM-41, CM-45, or CM-46
series switch.
The illumination is provided by an array of super-bright and energy efcient LED’s, which can be powered by 12 or 24 volts AC/DC.
Section 2
Setup
Switch Position Description
REMOTE / LOCAL On to enable LED
1
SW1
Color selection is made with Switches SW2 and SW3. SW2 determines the Active colour and SW3 determines the Idle color.
2
3
colour change from idle to Active with
press of the push button.
RELAY On to enable operation of the relay with activation of the push button
SPEAKER On to enable operation of
the speaker with activation of the
push button
Setting the Active Color (SW2)
Switch Position Description
1 ON = Green LED when Active
SW2
2 ON = Red LED when Active
3 ON = Blue LED when Active
Setting the Active Color (SW3)
Switch Position Description
1 ON = Green LED when IDLE
SW3
2 ON = Red LED when IDLE
3 ON = Blue LED when IDLE
Setup
Switch SW1 contains a bank of 3 dipswitches.
Dipswitch # 3 turns the speaker on or off. Dipswitch # 2 toggles operation of the relay, and # 1 allows you to choose
whether the colour will be changed locally via the push
switch, or remotely.
*Note: The CX-22 Washroom relay may be used with the Aura™, however an isolating relay must be wired in parallel with the lock, and the relay’s dry contact output wired into the CM-55i .
Page 1 of 5
Note: If all DIP switches are in the OFF position, there will be no color illuminated. This allows for no
Idle color or no Active color.
Once all DIP switches are set, proceed to Section 3 – Installation
Section 3
Installation
NOTE: If you will be including the optional Aura™ signage, follow that product’s installation instructions before installing
Aura™.
Aura™ CM-55i Flush Mount Illuminated Enclosure Installation Instructions
1. Assemble the drywall clamp to the box as per diagram
1. Determine the wire access location and drill hole of
sufcient size, or use center knock-out plug.
2. Using the template, cut a hole in the drywall. Pull the
wiring through the access hole and push the box through until the drywall clamp is on the back of the drywall. Tighten the 8-32 screws until the box is rmly mounted.
3. Remove circuit board from package and locate into the box Pull the wire through the hole in the centre of the circuit board, and then secure with the two small self­tapping screws (provided).
4.a Wire as per diagram 2 (typical installation). Route the
switch wiring through opaque diffuser panel, and install diffuser panel into box. It should t snuggly.
4.b If using a TX-9 transmitter to send the signal to an
RX-91 or RX-92 Receiver, attach the transmitter and wire it before installing circuit board into the enclosure and tting diffuser. See Diagram 3.
5. Screw in two #6-32 Allen-head screws (provided with switch) into the threaded center inserts, then attach wires
to switch and install switch over screws. Using the Allen key
(provided), locate the screws and tighten (by hand only).
6. Re-connect power and test for proper operation.
Section 4
Section 5
Warranty
Camden Door Controls guarantees the Aura™ (CM-55i series) to be free from manufacturing defects for 3 years from date
of sale.
If, during the rst 3 years, the Aura™ fails to perform correctly, it may be returned to our factory where it will be repaired or replaced (at our discretion) without charge. Except as stated
herein, Camden extends no warranties expressed or implied regarding function, performance or service.
Technical Data
Model CM-55i
Dimensions 6 1/2” H x 6 1/2” W x 2” D
(165 mm x 165 mm x 51 mm)
Construction Flame-resistant black ABS (Insert – translucent ABS)
Finish Attractive pebble nish
Mounting 4 x #12 wood screws with anchors
Input Voltage 12 or 24V AC/DC
Output Voltage 3 Volts DC for TX-9 (only)
Current draw 150 mA (max)
Sounder 3200 ± 300 Hz @ 85 dB
Lumina Red: 14.8 lumens, 1600 mW; Green: 3.8 lumens, 330 mW,
Relay Contact 1 x Form C
Contact Rating 3A @ 30 VDC
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
DISCOVER THE BEST IN DOOR ACTIVATING AND LOCKING PRODUCTS!
www.camdencontrols.com Toll Free: 1.877.226.3369
Page 2 of 5
File: CM-55i Manual. indd Rev1 Revised: 05/05/17
Part No:40-82B209
TO OPEN
Drywall Clamp
STEP 1
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
CM-55i Box
PCB
TM
Aura
CM-55i Dimensional & Assembly Diagram
Diffuser
2 x 8-32 x 1 1/2”
Phillips Screws
for drywall bracket
2 x #6 x 3/8”
Pan head
Phillips Screws
for mounting
STEP 2
PCB to box
CAMDEN DOOR CONTROLS
2 x 6-32 x 1 1/2”
Allen Screws to
mount the switch
to box assembly
CM-55i Dimensional & Assembly Diagram
DRAWN BY: DGW DATE: 04/26/17 REVISED:
SCALE: NONE
DRAWING No: DRG-CM-55i_01 FILE NAME: CM-55i diagram 1.vsd
STEP 3
Page 3 of 5
CM-45
Push Plate
PUSH
Mississauga, Ontario
Power terminals are not polarity sensive
Typical installaon shown
changes LED colour
acvaon change LED colour
LOCal dip on SW
REMOTE terminals
L4W 2T7
(x2)
5502 Timberlea Blvd.
-55 Enclosure (sold separately )
Power & Relay
Switch mounng holes (x2)
Terminal Strip
Circuit Board Mount
Box mounng screw locaons
CM
Diffuser Ring
All -Acve Switch
FILENAME: CM_55i Diagram 2.vsd
PWR 10-30
NO COM NC
ACV/DCV
SW2SW1
SW3
BLUE RED
2 3 1
ON
2 3 1
ON
IDLE COLOR
GREEN
CM-55i Wiring Diagram (Typical)
SW3 Dipswitch
- PBTN+
RELAY
2 3 1
ON
ENABLE
ACTIVE
SW2 Dipswitch
SW1 Dipswitchh
- REM + RF-TX +
SPEAKER
REM/LOC
Wire Access Hole
Camden Door Controls
CM-55i Wiring Diagram (Typical)
DRAWING No: DRG-CM-55i _02
SCALE: NONE DRAWN BY: DGW 04/26/17 REVISED:DATE:
.
, then set REMote/
, where remote device
. If it is desired to have switch
.
1 to LOCAL, and do not wire to the
Power
AC/DC
12 / 24 V
Door
Device
operator
or Locking
or Relay
ie - CX-33
Remote Switch
Page 4 of 5
or EMF-2
2.
NOTES:
1.
Power terminals are not polarity sensive
This installaon is intended for
applicaons
Cut the middle red lead to 1/4”
Cut both baery leads
switch lead to approximately
Strip the insulaon back on the
approximately 1/4”.
and remove release paper
from double sided tape.Line up and carefully install TX 9 on
back surface of mounng box
PWR 10-30
ACV/DCV
NO COM NC
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
CM-55i & TX-9
Power
AC/DC
12 / 24 V
BLUE RED GREEN
SW3
2 3 1
ON
RF-TX +
SW2SW1
2 3 1
ON
IDLE COLOR
ACTIVE
CAMDEN
LAZERPOINT
2 3 1
ON
- PBTN+
ENABLE
RELAY
CM-TX-9
- REM +
SPEAKER
REM/LOC
Diffuser
Switch
FILENAME: CM_55 i Diagram 3.vsd
Camden Door Controls
Wiring Diagram for CM-55i & TX-9
DRAWING No: DRG-CM-55i_03
SCALE: NONE DRAWN BY: DGW REVISED:DATE: 04/26/17
.
Connect the 3 wires from the TX-9 to
the circuit board exactly as shown.
The middle red wire that was cut short
STEP 3
-
+
-
is not used.
2 power wires as shown.
Install circuit board in box , & connect the
STEP 4
Set dipswitches for desired operaon.
Install diffuser, connect push switch wires to
terminal strip, then install switch.
Test for proper operaon.
2-wire retrofit
+
-
+
3 long ends to
as it is not used.
2” long.
, and the remaining
2“
<< Cut this lead to ¼”
TX-9
CAMDEN CM-TX-9
LAZERPOINT
STEP 2
STEP 1
Turn over,
NOTES:
Page 5 of 5
.
2.
1. 12/24
Loading...