Installation Instructions
Locate the 4 pilot holes in the enclosure. They are not drilled all the way through so that you may drill your own holes to match an existing layout or the site conditions
Drill 4 X 5/32” (minimum) holes through the base.
Mark the drilling locations on the wall with a pencil or center-punch.
Remove the base assembly and drill holes in the wall. Insert the appropriate wall fasteners.
Fasten the base assembly to the wall with the supplied screws
a. If using radio controls, insert the 9V mounting clip (CM-69 only) for the battery and use the double sided tape or velcro to secure the transmitter. b. If hard-wiring, use one of the supplied knock-outs to bring the wiring into the box.
Installation Instructions
Battery and transmitter not included. Must be ordered separately.
Hand insert and turn the two 6-32 screws supplied with the switch. Install wiring connectors to the switch, center, and place the switch over the two screws.
Tighten the screws firmly using the allen key provided with switch.
IMPORTANT! As you tighten the screws, ensure the switch stays centres in the opening and does not rub on the inside edge of the housing.
Parts Included: 9V battery mounting clip (CM-69 only) 4 X 6-32 self-tapping screws 4 solid wall anchors