CAMDEN Sure-Wave CM-324, Sure-Wave CM-324/N, Sure-Wave CM-324/W, Sure-Wave CM-325, Sure-Wave CM-325/N Installation Instructions Manual

...
Active Infrared “Hands-Free” Switch
Section 1: General Description
Sure-Wave™ hands-free” switch is an active infrared device designed for use with an automatic door operator or other access control product.
The assembly will t in a variety of locations from a 1 3/4” door frame to a 1-gang or 2-gang electrical box. Various size surface mounting boxes are also available from Camden.
Three standard face plate widths are available:
CM-324: 2 ¾” x 4 ½” polycarbonate or stainless steel,
ts on single gang electrical boxes.
CM-324/ N: 1 ¾” x 4 ½” polycarbonate or stainless
steel, ts 1 ¾” door frames or our CM23D Jamb box.
CM-324/ W: 4 ½” x 4 ½” polycarbonate or stainless steel,
ts on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face (/1), with the waving hand symbol (/2), or with the waving hand symbol and words: WAVE TO OPEN (/3).
CM-324 Series
Installation Instructions
BY CAMDEN
4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32 screws provided.
6 – Apply power and adjust range and time delay via the potentiometers on the front of the unit. (See Section 4 for adjustments)
7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Smooth Wall Finish
Wall
Section 2: Installation
Mounting
Sure-Wave™ may be mounted in door jambs, single or double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for outdoor or wet locations. If using with Automatic doors install in
accordance with ANSI A156.10 / A156.19. Select from one of the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-324
1a – If using an in-wall box ensure the box is plumb and
square, and ush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Bring your 4-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
Page 1 to 4
Flush
Wall Box
Rough Wall
Finish
Recessed Box
Unaligned Box
Diagram 1 - Proper Box Installation
CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
2-GANG (or 4x4) ELECTRICAL BOX: CM-324W
1a – If using an in-wall box ensure the box is plumb and
square, and ush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
1c – If using a 4 x 4 box, ensure the box is plumb and
square, and ush with the wall surface, then attach the metal adaptor plate (included in the CM-324W package)
to the box using appropriate fasteners.
2 – Bring your 4-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32 screws provided.
6 – Apply power and adjust range and time delay via the potentiometers on the front of the unit. (See Section 4 for adjustments)
7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
DOOR FRAME: CM-324N
1a – If mounting directly in a 1¾” wide aluminum jamb, make a cutout in the door frame at the intended location
as per Diagram 2. (See Diagram 2 on page 4)
Drill and tap two mounting holes as shown.
1b – If mounting the unit in our CM-23d deep jamb box, rst mount the jamb box according to the instructions packaged with the enclosure. Using the CM-23D as a guide, drill a wire access hole through the jamb to sh the
wiring through.
2 – Bring your 4-conductor wire through the back or side
of the enclosure (or Jamb) and leave approximately 6” tail
for wiring connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)
5 – Attach the unit to the enclosure or jamb using the two #6-32 screws provided.
6 – Apply power and adjust range and time delay via the potentiometers on the front of the unit. (See Section 4 for adjustments)
7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Page 2 to 4
Wiring
CAUTION: Do not apply power to the unit until all second- ary wiring is complete, and dip-switches have been set.
The CM-324 can be powered from 12 or 24 volts, AC or DC. Connect the two Red wires, (which are non-polarity
sensitive) to the power source.
The output is a form C relay. N.O is Blue, N.C. is Violet, and Common is Green. Selecting the correct output is also dependant on the operating mode chosen. (See Section
4) Most applications will utilize the N.O. and Common
terminals.
Section 3: Applications & Set-up Applications
See Diagram 3 for the location of the Dip switches.
Range
Adjustment
Photo Eye
Red LED
Time Delay Adjustment
Diagram 3 - Location of Adjustments
CM-324
Dip Switch
Switch 1 – Normal Mode/Fail-Safe Mode
Choose Normal Mode if you wish the N.O. contact to remain open if the power were to fail. This is the factory setting.
Choose Fail-safe Mode if you wish the contacts to close upon power fail. Move the Dip switch to OFF position, and wire your device to the Common and N.C. wires.
Switch 2 – Time Delay Mode/Toggle Mode
Factory setting is Time Delay (Sense) mode, whereby the
contact closure will be adjustable from 1 – 5 seconds
using the Time Delay Potentiometer.
In Toggle (or Switch) mode, when the CM-324 is activated
once, the relay will stay energized until it is activated once again. (The adjustable timer is inactive in this mode)
Wiring Pigtail
Red Red Blue Green Violet
12-24V Power
N.O. COM N.C.
CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
Switch 3 – LED On/LED Off
This switch disables the LED,
should this feature be desired.
Door Frame
CM-324/N3
Factory setting is ON.
Once the Dip switches have been
set, and the unit is installed in the frame or enclosure, apply power to the unit and observe operation.
Set both potentiometers to minimum setting initially (fully counter-clockwise).
See Diagram 3 for location.
Adjust the range potentiometer by turning the pot in a clockwise
1
"
25mm
manner, and passing your hand
in front of the unit. Rotate the pot
until the desired range is obtained.
See Diagram 5 for patterns.
Next, adjust the time delay potentiometer by turning clockwise
Diagram 5
Wheelchair
Sticker
Placement
until the desired time delay is
obtained. It is sometimes benecial
to leave this adjustment set to minimum and utilize the time delay on the door operator, if present.
NOTE: Timer is non-functional in Toggle Mode.
Install the faceplate using the screws provided.
Do not overtighten!!
OPTIONAL – Apply the included Wheelchair logo to the
frame or wall at desired location. See Diagram 5 on page 4.
Do not apply directly to the faceplate!!
If using this product with an Automatic Door, proceed to
Section 4 for System Inspection Instructions.
Section 4: System Inspection Instructions
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10 or A156.19 guidelines). This will advise the person entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how to test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of its components become damaged.
4. Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement.
Section 5: Technical Data
Model CM-324
Body Size 4” L x 1” W x 1 ½” Deep
Mounting 2 x #6-32 MS
Faceplates Sizes Jamb, 1-gang, & 2-gang
Technology Infra-Red with Coded Modulated Carrier
Security Automatic Self-changing ID
Operating Modes Pulse (sense) / Toggle
Operating Temp -4 to +153 ºF (-20 to +85 ºC)
Operating Voltage 12-24 Volts, AC/DC ± 12%
Current Draw 50 - 60 mA.
Response Time 100 ms.
Activation Range: Minimum Maximum
Relay Output Form C (SPDT)
Relay Contact Rating 5 amps @ 30 VDC
Output Type Normal or Fail-Safe
Connections 11” 22 AWG Leads
Time Delay 1 to 5 Seconds
Electrical Life 100,000 Operations@ Rated Capacity
1” – 3” 1” – 26” Factory Set to 12” (304mm)
500,000 Operations@ ½ Rated Capacity
Section 6: Warranty
Camden Door Controls guarantees the Sure-Wave™ to be free from manufacturing defects for 3 years from date of sale.
If during the rst 3 years the CM-324 fails to perform
correctly, it may be returned to our factory where it will be repaired or replaced (at our discretion) without charge. Except as stated herein, Camden extends no warranties expressed or implied regarding function, performance or service.
Questions? Call us toll-free at 1-877-226-3369
Page 3 to 4
CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
1
1
/2"
38 mm
9
/32"
3
83mm
Drill & Tap 6-32 (2 holes)
Diagram 4
Jamb Cutout Dimensions
7
/8"
2
73mm
3”
(75mm)
0’
1’
2’
3’
30”
(762mm)
Diagram 4
Adjustable Range Settings
Push Buttons
Key Pads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
www.camdencontrols.com Toll Free: 1.877.226.3369
Page 4 to 4
File: CM-324 hands-free switches manual_R3.indd Revised: 05/03/2018 Part No: 40-82B100
Loading...