CAMDEN CX-ED1079L, CX-ED1079DL Installation Instructions Manual

This Package Includes:
1- 4 PIN power connector
1- 3 PIN door status connector
1- ESP1B, ESP3B and ESP4B faceplates
4- Wire nuts
5- M5 x 12 mm screws
1. Description
2- #10 x 1 1/4” wood screws
2- #10-32 x 1/2” screws
2- Mounting brackets
2- Spacers
1- Varistor
CX-ED1079L/DL
‘Universal’ Electric Strike
Installation Instructions
UL 1034 UL 294
Camden CX-ED1079L/DL Grade 1 ANSI strikes for cylindrical locksets offer the very best strike quality and performance, with three stainless steel faceplates provided. The ‘Universal’
strike design delivers unparalleled application exibility, with eld selectable voltage, fail safe/fail secure operation and
mechanical adjustment of the strike body.
2. Specifications
Voltage
Current Draw
Static Strength
Dynamic Strength
Endurance
Mode
Mech. Adjustment
Operation
Duty
12/24V AC/DC
260mA@12V DC 150mA@24V DC
1,500 Lbs.
70 Ft-Lbs.
1,000,000 Cycles (Factory Tested) 250,000 Cycles (UL Verified)
Field Selectable Fail Safe/Fail Secure
Strike Body/Faceplate
AC-Buzz, DC-Silent
Continuous
UL 294 Performance Levels
- Line Security = Level I
- Attack Level = Level I
- Endurance Level = Level IV
- Standby Power = Level I
3. Dimensions
5/8”
(16mm)
4 1/8”
(104mm)
4 7/8”
(123mm)
1 7/32”
(31mm)
1 3/8”
(35mm)
1 3/4”
(44mm)
1 1/4”
(32mm)
1 5/8”
(42mm)
3/4”
(19mm)
Latch Bolt Monitor
SPDT, 100mA @ 24V DC
Dimensions (Body) CX-ED1079L:
3 3/8” H x 1 3/4” W x 1 7/32” D (86mm x 44mm x 31mm)
CX-ED1079DL: 3 3/8” H x 1 3/4” W x 1 3/8” D (86mm x 44mm x 35mm)
Page 1 of 3
3 3/8”
(86mm)
CX-ED1079L
1/8”
(3mm)
3 3/8”
(86mm)
(3mm)
CX-ED1079DL
1/8”
(32mm)
1 7/32”
(31mm)
1 3/8”
(35mm)
1 1/4”
1/2”
(12mm)
CX-ED1079L
CX-ED1079DL
4. Installation
Jamp
CX-ED1079L/DL ‘Universal’ Electric Strike
1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws
and pressed metal nuts. Do not tighten.
3. Spacers are used to assure ush nal assembly of
faceplate into jamb. Add one or more spacers between
jamb and mounting bracket when face plate extends
beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting
Mounting Bracket
Spacer
Spacer (Option)
M5x12 Flat-Head Screw (2pcs)
Spacer
bracket & the lip bracket. Make sure the clearance hole in the spacer aligns with the hole in mounting bracket.
4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32 screws and lockwashers.
6. Tighten secure M5x12 screws holding mounting brackets
to jamb.
4 7/8”
(124mm)
3 1/2”
(89mm)
4 1/8”
(105mm)
ESP1B + ESP2B
DL:
L:
1 7/32”
(31mm)
1 3/8” (35mm)
3 3/8”
(86mm)
M5x12 Screw
Vertical Centerline
Note: The products are intended to be installed in accordance with the installation wiring diagram, mechanical assembly drawings provided with each product, the local authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70. When installed in fail secure mode, the local authority shall be consulted with regard to the use of possible panic hardware to allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and in such a location so as to not impair the operation of an emergency exit device or panic hardware mounted on the door.
DL:
DL:
L:
L:
1 7/32”
(31mm)
1 3/8” (35mm)
1 7/32”
(31mm)
1 3/8” (35mm)
3 3/8”
(86mm)
3 3/8”
(86mm)
1 3/8”
(35mm)
5 11/16”
(144mm)
6 1/8”
(155mm)
ESP3B
(200mm)
6 3/8”
(168mm)
7 3/8”
(187mm)
6 7/8”
(173mm)
7 7/8”
ESP4B