Camden CV-634PR User Manual

OPERATION MODES:
Model CV-634PR
Everswitch Proximity Reader Plus Keypad
Installation Instructions
Output formats: 26 bit Wiegand with programmable
site code
Power Supply: 5 to 12 VDC
Power Consumption: Max 150 mA
Mounting: Universal (single gang box)
Environment: IP68 ; 100% relative humidity
Operating Temperature: - 20 to + 70ºC
Dimensions: 120 x 90 x 20mm (4.72” x 3.54” x .79”)
Anti-tamper Optical protection
Certifications: Complies with FCC Part 15
Model CV-634PR is equipped with 2 electronically interlocked devices - the Proximity Reader and the Piezoelectric Keypad.
It supports the following operation modes:
1. Prox + Pin. Present Prox card. The unit will read the content and send it over the Data wires to the host. Enter PIN code. The unit will send each digit over the same Data wires to the host. The Keypad and the Prox reader are interlocked so that when one is functioning the other is inhibited until the data is transmitted.
2. Prox Only. The prox electronics is independently communicating via Data wires.
Wiring
COLOR FUNCTION ELECTRICAL FUNCTION
RED Input Voltage 5 to 12 VDC
BLACK Ground
GREEN Data 0 Open collector 1Kohm pull-up to internal +5V
WHITE Data 1 Open collector 1Kohm pull-up to internal +5V
BROWN LED Input No Voltage
BLUE CCTV output
VIOLET Housing Ground
ORANGE Buffered Input
GREY Tamper Output Open collector 0,100 A “Low” when light sensed
3. Keypad Only. The keypad electronics is independently communicating via Data wires..
Verification
Apply power to the unit. During the rst 5 seconds it is
possible to reprogram the Site code (see instructions on next page). The unit will activate the buzzer and the Yellow LED 3 times. At the same time the RED or the Green LED will come ON depending on the Central Computer setup.
Present a valid HID encrypted card at 5 cm (2”) distance maximum. The unit will activate the Buzzer and the Yellow Led once.
Enter any combination of PIN code up to 65534. The unit will activate the Buzzer and the Yellow Led with each pressed key.
Open collector 0,250 A activated with each
key for 30 sec
26 BIT WIEGAND SPECIFICATIONS:
Model CV-634PR Piezo Proximity Reader Manual
The following WIEGAND output is sent each time the # (enter) key is pressed.
P S S S S S S S S N N N N N N N N N N N N N P
BIT 1 2 9 10 25 26
BIT 1 is an even parity for the following 12 bits. The sum of bits 1-13 is even.
BITS 2-9 are the programmable SITE CODE. While pressing * during the rst 3 seconds on power up it is possible to program the site code. Any number from 000 to 255 is possible.
BITS 10-25 this is the number entered prior to pressing # (enter). Leading 0’s are added as required.
Bit 10 is most signicant.
BIT 26 Odd parity over previous 12 bits. The sum of bits 14-26 is odd.
EXAMPLE: A card code of 123 entered:
1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1 (site code 004)
The data is sent at 2 msec per bit with a pulse duration
of 70 μsec
A buzzer beeps with each key press.
Note: Camden Piezo Proximity readers plus Keypad are programmed with default Site Code “000”. The maximum Site Code is 255.
Example to set site code to 100. Disconnect the power supply for a minimum of 10 seconds. Connect the power
supply, and the unit will start beeping. During the rst 5
seconds perform the following:
Enter * The keypad enters programming mode, the red LED flashes.
Enter 100 # The site code of 100 is assigned.
1. Blue Wire - PRESSING any key on the keypad will generate a 30 second 0.25 amp intermittent duty grounding output.
2. Orange Wire - When the Hold Line, Orange wire, is pulled “low”, any codes entered on the keypad are stored in the buffer. When the Hold Line is released to logic “high” – the buffered code data is sent.
2. Grey Wire - When the photodiode senses ambient light the Grey wire is pulled “LOW”
An error code is generated by any of the following:
a) Pressing the # key with no preceding digits;
b) Pressing any number of only zero’s prior to pressing the # key, or;
c) Pressing 65,535 or any number above 65,535. An Error Code will send all binary 1’s to your panel.
DO NOT Program your panel to accept code number 65,535.
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
www.camdencontrols.com Toll Free: 1.877.226.3369
File: CV-634PR Instructions..indd- Rev1 Revised: July 4th, 2014
Part No: 40-82B042
Page 2 of 2