(2) 0.15" x 1.06" (4mm x 27mm)
Self-tapping screws
(1) 1N4007 Two-electrode valve
(2) 0.23" x 1.2" (6mm x 30mm)
Rubber plug
1. DESCRIPTION
The CM-550SK is a single door standalone keypad with a
Wiegand input/output interface. It is suitable for mounting
either indoors or outdoors in harsh environments. It is
housed in a strong, sturdy and vandal proof Zinc Alloy
electroplated case. The electronics are fully potted so the
CM-550SK is waterproof and conforms to IP68.
The CM-550SK supports up to 2000 users with a 4~6 digit PIN.
These features make CM-550SK an ideal choice for door access
for commercial and industrial applications such as factories,
oces, warehouses, laboratories, banks and prisons.
2. FEATURES
• Waterproof, conforms to IP68
• Strong Zinc Alloy Electroplated anti-vandal case
• Full programming from the keypad
• 2,000 users
• PIN length 4~6 digits
• Backlit keypad
• Wiegand input & output
• One programmable Relay output, NO, NC, COM
• Adjustable Door Output time, Alarm time, Door Open time
• Very low power consumption (< 60mA)
• Easy to install and program
• Built in light dependent resistor (LDR) for anti-tamper
• Built in buzzer
• Red, Yellow and Green LEDs display the working status
• 12-24V DC +/- 10%
• Three-year warranty
(1) 0.78" x 2.4" (20mm x 60mm)
Star screw driver
3. SPECIFICATIONS
Model
Voltage
IP rating
Idle Current
Contact Type
Contact Rating
Alarm Output Load
Ring Bell Load
Card Read Distance
Card Frequency
Keypad Format
Operating Temp.
Dimensions
CM-550SK-V2
12 DC +/- 10%
68
25mA
(1) Form 'C'
1 Amp@30VDC
1 Amp@30VDC
1 Amp@30VDC
1.75" (40Mm) Max
125KHz, EM and HID
4 bit, 8 bit and 26 Bit
-49°F to 113°F (-45°C to 55°C)
4 13/16" H x 3 1/8" W x 1 1/16" D
(121.67mm x 79.5mm x 26.42mm)
Page 1 of 11
Page 2
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Front View
1 1/16”
(26.42mm)
(79.50mm)
(16.49mm)
2 3/8”
(60.83mm)
3 1/8”
5/8”
4 13/16”
(121.67mm)
3 1/8”
(79.50mm)
(91.71mm)
3 5/8”
4 13/16”
(121.67mm)
5. WIRING
No.MarksColourDescription
1BELL_APinkDoorbell button
2BELL_BPinkDoorbell button
3D0GreenWiegand output D0
4D1WhiteWiegand output D1
5ALARMGrayAlarm
6OPENYellowRequest to Open (BUZ)
7D_INBrownDoor Contact (LED)
8DCRedPower IN
9GNDBlackGround
10NOBlueRelay NO
11COMPurpleRelay Com
12NCOrangeRelay NC
Side View
1/2”
(13.46mm)
Back View
1 9/16”
(39.75mm)
4. INSTALLATION
1. Remove the back cover from the keypad using the supplied
special screw driver.
2. Drill 2 holes on the wall for the self tapping screws and 1 hole
for the cable.
3. Put the supplied rubber plugs into the two holes.
4. Fix the back cover rmly on the wall with 4 at head screws.
5. Thread the cable through the cable hole.
6. Attach the keypad to the back cover.
6. SOUND AND LIGHT INDICATION
OperationLED ColourBuzzer
StandbyRed Flash
Press KeyDI-
Read CardGreenDi-
Door 1 OpenGreenDi-
Door 2 OpenGreen FlashDi-
Operation SuccessfulGreenDi-
Operation FailedDi-Di-Di-
PIN inputtingRed
Pin ReadingRed
Under MenuRed
Under SettingOrange
Page 2 of 11
Manager Card EnterOrangeDi-Di-
Manager Card ExitRed FlashDi-
AlarmRed Quick FlashAlarm
Page 3
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
7. QUICK PROGRAMMING GUIDE
7.1 Administrator Setting
StandbyMaster CodeMenuSettingRemarksFunctions
Red FlashRedRedOrange
*Master Code #
00
05Anti-duress PIN#Anti-duress PIN
070000#Delete All Users
51Master open
New Master Code #,
Repeat New Master Code #
(Note: Code length: 6-8 digits)
Factory Default:
999999
Change the Master Code
7.2 User Setting
StandbyMaster CodeMenuSettingRemarksFunctions
Red FlashRedRedOrange
*Master Code #
11User ID number #, PIN #
12User ID Number #
132 #Default 2Entrer by Card/PIN
140-99 #Default 5Set Door Relay Time
0 #
15
1 #Ready Setting-Toggle Mode
Users can be added
continuously
without exiting
programming
mode
Users can be added
continuously
without exiting
programming
mode
Default 0
To add PIN users
To Delete Users
Ready Setting-Pulse Mode
Page 3 of 11
Page 4
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
7.3 System Setting
StandbyMaster CodeMenuSettingRemarksFunctions
Red FlashRedRedOrange
*Master Code #
300-15 #
31
330-2 #
341-3 #Default 1To set alarm time in minutes
35
0 #
1 #Standalone for Single Door
0 #
1 #Lock out mode
2 #Alarm mode
Default 0To Set Facility Code
This setting is not
affected by resetting
to factory default.
This setting is not
affected by resetting
to factory default.
Default 0
7.4 User Optional Setting
StandbyMaster CodeMenuSettingRemarksFunctions
Red FlashRedRedOrange
*Master Code #
41
0 #Buzzer is turned off, except while in programming mode
1 #Default 1Buzzer will sound during key presses
Wiegand Reader
To set keypad
transmission format
0=26 bit weigand
1=4 bit burst
2=8 bit burst
Normal mode
42
43
Notes:
1. Master code must be 6-8 digits.
2. Anti-duress PIN must be 8 digits.
3. User PIN is 4-6 digits.
4. The user ID number is any number from 1-2000
5. Door open time is 0-99 second, 0=50mS.
6. While operating the keypad, pressing # means to conrm the input digits, in operation of a cycle adding or deleting PIN
code, pressing # means to end the cycle operation and back up the operation; pressing * means to exit the operation.
7. Keypad Wiegand modes are set at the factory to 26 bit. If the output format is changed through programming, the
changes are not affected by a reset to factory defaults.
Facility code is any digit between 0-15, PIN code is 4-6 digits.
Example: facility code: 15
PIN code: 999999
Press 999999#, then output format will be 0015999999
Model 1: 4 Bit
The output data is provided in the following format after every
key is pressed:
KeyOutput in HexOutput in Binary
000000
11. MULTI-WORKING MODE
There are 3 working modes with this device.
1. Wiegand Reader.
2. Standalone for single door.
3. Anti-passback for single door.
The factory default is Standalone for single door (we can
change the default model according to customer order). User
can modify the working mode when the device reset to factory
default, the setting is still valid.
11.1 Wiegand Reader Mode
In this mode, the access control works as a reader, connected
with the common access controller.
It has the following function:
• Modify master pin
• Set facility code
• Set the keypad transmission format
• Set optional setting
• Anti-Tamper alarm
110001
220010
330011
440100
550101
660110
770111
881000
991001
*A1010
#B1011
Page 7 of 11
Page 8
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Model 2: 8 Bit
The output data is transmitted in the following format after
every key is pressed:
KeyOutput in HexOutput in Binary
0011110000
1111100001
2211010010
3311000011
4410110100
5510100101
6610010110
7710000111
8801111000
9901101001
*A01011010
#B01001011
11.2 Stand alone for single door
In this mode, the device supports connecting external card
reader for exiting door. The users of Zone 1 or external can
open the door by valid card or PIN.
11.3 Anti-Passback for single door
In this mode, this unit install outside is for entering door,
external reader inside for exiting door, the users can only
enter door when read valid card on the machine, and
exit from the inside external reader. If without the
entering record.
Note: this is only for card users of Zone 1, PIN users
of Zone 1 an all users of Zone 1 are invalid.
12. DIAGRAMS FOR WORKING MODES
BELL_A
BELL_B
Bell
Orange
PinkPink
Power off the lock keep unlocking
NC1
COM1
NO1
Purple
Blue
Power on the lock keep unlocking
ALARM1-
Gray
Alarm
D_IN1(LED)
Brown
Exit button
Door contact
OPEN1(BZ)
GND
Yellow
Black
AC1(+12V)
Red
White
+12V
D1
D0
Green
12V
RF
SIB
External Reader
12V
D1
D0
Power Supply
GND
Means connect together
DC12V common power
Page 8 of 11
Connect with GND
Mode Standalone for single door diagram
Mode Anti-passback for single door diagram
IN4007
Page 9
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
BELL_B
Bell
BELL_A
PinkPink
NC1
Orange
Connect with special power 1
Means connect together
COM1
Purple
PUSH
NO1
Blue
GND
ALARM1-
Gray
Alarm
D_IN1(LED)
Brown
Door contact
Connect with GND
OPEN1(BZ)
Yellow
Exit button
GND
Black
IN4007
AC1(+12V)
Red
D1
White
+12V
D0
Green
RF
SIB
External Reader
12V
D1
D0
GND
COM
NC
Power off the lock keep unlocking
DC12V special power
DC12V/3A
Special power 1
NO PUSH
Power on the lock keep unlocking
GND
special power with lock 1 diagram
Mode Standalone for single door diagram
Mode Anti-passback for single door diagram
+12V
+12V
Relay for zone 1
COM1
NC1
Orange
Purple
NO1
Blue
Page 9 of 11
Page 10
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
BELL_B
Bell
BELL_A
PinkPink
NC1
Orange
COM1
Purple
NO1
Blue
Means connect together
ALARM1-
Gray
Alarm
D_IN1(LED)
Brown
OPEN1(BZ)
Yellow
LED
BZ
GND
Black
GND
AC1(+12V)
Red
12V
Access Controller
D1
White
D1
D0
Green
D0
Mode Wiegand reader diagram
Page 10 of 11
Page 11
13. SIMPLE TROUBLESHOOTING
CodeFaultFault CauseSolutions
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
1Problem in PIN setting
2PIN can't open door
3Alarms at normal condition
1. PIN is not standard
2. Set Password at reader mode
1 use PIN 1234
2 entry mode setting
During installation, light leak
under bottom
4
5Keypad light is not bright
Mode of keypad light setting
is wrong
6Can't enter master modeForget master code
14. RESET TO FACTORY DEFAULT
a. Disconnect power from the unit.
b. Press and hold # key whilst powering the unit back up.
c. On hearing two “Di” release # key, system is now back factory settings.
Note: Only installer data is restored, user data will not be affected.
1. PIN shouldn’t be 1234
2. PIN is 4 to 6 digits
3. Don’t set PIN at reader mode
1. 1234 is original PIN, can’t open the door,
should be modied as other PIN
2. Set open mode as entry by card or PIN.
During installation, device should be close to wall
1. Set keypad light as shine or auto
2. Under auto mode, light shine after press
keypad, delay 30 seconds
Reset to Factory Default, master code will be
999999, only installer data is restored, user data
will not be affected
Opening New Doors to