1) Read the information for use (user manual).
2) Please keep this user manual in a safe place during the lifetime of the ampli­er. The user manual forms an integral part of the amplier. Reselling of the amplier is only possible if the user manual is available. Any changes made to the amplier have to be documentated in writing and passed on to the buyer in the event of resale.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this amplier near water (for example, in damp rooms or near a swimming pool).
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the user manual.
IMPORTANT SAFETY INSTRUCTIONS
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9) Protect the power cord from being walked on, pinched or damaged in any other way. Pay particular attention to plugs and the point where they exit from the amplier.
10) The amplier may only be used in accordance with the information provided in the user manual. Before and during the usage of the amplier please ensure that all recommendations, especially the safety recommendations as detailed in the user manual , are adhered to. The VORTEX–Amplier is designed for the amplication of pulsed audio signals and the amplier should only be connected to speakers with an average impedance that is not lower than the impedances specied in points 3.8.3, 3.8.4
and 3.8.5.
11) Do not place this amplier on an unstable cart, stand, tripod, bracket, or table. The device may fall, causing serious injury, and serious damage to the device itself.
12) The amplier can only be disconnected from the power supply by removing the plug, which must be freely accessible at all times. Unplug this amplier during lightning storms or when unused for long periods of time.
13) Refer all servicing to qualied service personnel. Servicing is required when
the power-supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the amplier,
the amplier has been exposed to rain or moisture,
the amplier has been dropped or suffered damage in any other way.
the amplier exhibits a distinct change from its normal function or
performance.
P.2
USER MANUAL
VORTEX 3 QUADRO
Page 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION – HIGH VOLTAGE HAZARDS
EXIST WITHIN THIS PRODUCT.
REFER ALL SERVICING TO AUTHORISED PERSONNEL
1. Read the information for use (user manual)
When shipping the VORTEX amplier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was origi­nally packed at the factory.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL, IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS
VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE
THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER
TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE
LITERATURE ACCOMPANYING THE AMPLIFIER
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS
THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE SPEAKON
CONNECTORS THAT COULD POTENTIALLY BE LIFE THREATENING.
CAUTION – RISK OF ELECTRIC SHOCK – DO NOT OPEN
WARNING – TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS
AMPLIFIER TO RAIN OR MOISTURE
THE AMPLIFIER MAY ONLY BE CONNECTED
TO A SOCKET WITH A CONNECTION TO GROUND.
2. Environments
Use this amplier only in E1, E2, E3 or E4 environments according to EN55103-2 – Electromagnetic compatibility – Product-family norm for audio, video and audio-visual installations as well as for studio-and lighting-control inastallations for professional applications – Part 2: Immunity.
3. Ventilation
Slots and openings in the cabinet are provided for ventilation, to ensure reliable operation of the amplier and to protect it from overheating. These openings must not be blocked or covered. This amplier should not be installed unless proper ventilation is provided or manufacturer’s instructions have been adhered to.
4. Water And Moisture
Do not use this amplier near water (for example, in damp rooms or near a swimming pool).
5. Cleaning
Unplug this amplier from the wall outlet before cleaning. Do not use liquid or aerosol cleaners.
6. Power-cord Protection
Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon them or against them, paying particular atten­tion to cords and plugs, and the point where they exit from the amplier.
USER MANUAL
VORTEX 3 QUADRO
EXPLANATION OF SYMBOLS / SAFETY
P.3
Page 5
7. Lightning
For added protection of this amplier during lightning storms, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the amplier due to lightning and power-
SAFETY
line surges. Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external disconnecting all poles from the mains.
8. Interference of external objects and/or liquids with the appliance
Never push objects of any kind into this amplier through openings as they may touch dangerous voltage points or short out parts that could result in a re or electric shock. Never spill liquid of any kind on the amplier.
9. Accessories
Do not place this amplier on an unstable cart, stand, tripod, bracket, or table. The amplier may fall, causing serious injury, and serious damage to the product. Any mounting of the amplier should follow the manufacturers instructions, and should use a mounting accessory recommended by the manufacturer.
10. Connecting
When you connect the amplier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections.
11. Sound Volume
Reduce the volume to minimum before you turn on the amplier to prevent sudden high levels of noise (decibel) which may cause hearing or speaker damage. (See also 4.2.1 Volume control)
12. Damages that require service
Unplug this amplier from the mains supply and refer to your dealer/distributor or other authorised repair workshop if any of the following situations occur:
if liquid has been spilled, or objects have fallen into the amplier
if the amplier does not operate normally as described in the user manual.
Operate the controls only as described in the user manual.
if the amplier has been dropped or damaged in any other way.
when the amplier exhibits a distinct change from its normal function or
performance.
13. Servicing
Do not attempt to service this amplier yourself. As opening or removing covers may expose you to dangerous voltage or other hazards, the amplier may only be opened by qualied personnel. Please refer to your dealer/distributor.
14. Servicing and Replacement Parts
All service and repair work must be carried out by a CAMCO authorised dealer. When replacement parts are required, please ensure that the dealer/distributor only uses replacement parts specied by the manufacturer. The use of un­authorized replacement parts may result in injury and/or damage through re or electric shock or other electricity-related hazards.
15. Safety Check
Upon completion of any service or repairs to this product, ask the dealer/ distributor to perform safety checks to determine that the amplier is in proper operating condition. Recommendations on how to carry out the safety test can be found in DIN VDE 0701-1 Maintenance, Modication and Test of Electronic Appliances.
P.4
USER MANUAL
VORTEX 3 QUADRO
Page 6
EC Declaration of Conformity in accordance to EC Directives:
electro-magnetic compatibility (Council Directive 89/336/EEC, as amended by Directives 92/31/EEC and 93/68/EEC); low-voltage electrical equipment (Council Directive 73/23/EEC )
Manufacturers Name:
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen
Manufacturers Address:
Fischpicke 5, D-57482 Wenden – Germany
Declares that the product with the model name:
CAMCO Power amplier VORTEX-3-QUADRO
Conforms to the following standards:
EN60065 Security
EN55103-1 Emission
EN55103-2 Immunity
The operating conditions and application environments presupposed in the information for use (user manual) are to be kept accordingly. Please Note: The following formulations have been chosen:
VORTEX-3-QUADRO for the type plate and for the EC declaration of conformity. VORTEX 3 QUADRO for the front face of the appliance and for the text in the
user manual.
Wenden, 09.12.2004
Joachim Stöcker
USER MANUAL
VORTEX 3 QUADRO
EC DECLARATION OF CONFORMITY
P.5
Page 7
P.6
P.2
IMPORTANT SAFETEY INSTRUCTIONS
P.3
EXPLANATION OF SYMBOLS / SAFETY
P.5
EC DECLARATION OF CONFORMITY
P.6
CONTENTS
P.7
1 WELCOME
1.1 Welcome to CAMCO
CONTENTS
1.2 Unpacking
P.8
1.3 The Amplifier
P.9
2 FACILITIES
2.1 VORTEX 3 QUADRO – The Front
2.2 VORTEX 3 QUADRO – The Rear
P.10
2.3 Factory settings
P.11
3 INSTALLATION
3.1 On/Off Switch
3.2 Precautions
3.3 Mounting
P.12
3.4 Cooling
3.5 Ground Lift
3.6 Mode Indicators
P.13
3.7 Mode Selector
3.8 Basic Concepts
3.8.1 Stereo
3.8.2 Parallel-Mono
P.14
3.8.3 Mono-Bridge
3.9 Wiring
3.9.1 XLR Connection
P.15
3.9.2 SPEAKON Connection
P.16
3.9.3 Four-Channel Operation
3.9.4 Three-Channel Operation
P.17
USER MANUAL
VORTEX 3 QUADRO
3.9.4.1 Stereo / Parallel-Mono
3.9.4.2 Stereo / Mono-Bridge
3.9.5 Two-Channel Operation
3.9.5.1 Parallel-Mono / Parallel-Mono
P.18
P.19
P.20
P.21
P.22
P.23
P.24
3.9.5.2 Mono-Bridge / Mono-Bridge
3.9.5.3 Parallel-Mono / Mono-Bridge
4 OPERATION
4.1 Precautions
4.2 Controls
4.2.1 Volume Control
4.2.2 Gain Selector
4.2.3 Limiter Switch
4.3 Indicators
4.3.1 On LEDs (multifunctional)
4.3.2 Signal LEDs
4.3.3 Clip LEDs (multifunctional)
4.4 Power Amp Protection Systems
4.4.1 Clip Limiter
4.4.2 Under Impedance Limiter
4.4.3 SOA Protection
4.4.4 Speaker Protect Limiter
4.4.5 DC Protection
4.4.6 DC Servo
4.4.7 Over Current Protection
4.4.8 Thermal Protection
4.5 Mains Protection
4.5.1 Inrush Current Limitation
4.5.2 Mains Over Voltage Detection
4.5.3 Mains Failure Detection
4.5.4 Fuse Protection
4.6 Main SMPS Protection
4.6.1 Over Current Protection
4.6.2 Thermal Protection
4.7 Fans
4.8 Filter Cleaning
P.25
5 OPTIONS
5.1 CAI (CAMCO Audio Interface)
5.1.1 Wiring
5.1.2 CAI Address Settings
P.26
5.1.3 CAI Status Indicator
P.27
6 TROUBLESHOOTING
6.1 On LED Flashing Sequences
P.28
6.2 Problem: No Sound
6.3 Problem: No Sound or Sound Is Too Low
6.4 Problem: No Channel Separation
6.5 Problem: Distorted Sound
P.29
6.6 Problem: Hiss
6.7 Problem: Squeals and Feedback
P.30
7 SPECIFICATION
P.32
8 MEASUREMENTS
P.36
9 WARRANTY INFORMATION
9.1 Summary Of Warranty
9.2 Items Excluded From This Warranty
9.3 What CAMCO Will Do
9.4 How To Obtain Warranty Service
9.5 CAMCO’s Product Improvement
P.37
10 SERVICE INFORMATION
10.1 Owner’s Information
10.2 Nature Of Problem
10.3 Expired Warranty
10.4 Shipping Address
P.38
11 MAINTENANCE INFORMATION 12 DECOMISSIONING
P.39
COMPANY INFORMATION
Page 8
1.1 Welcome to CAMCO
Established in 1983, sound reinforcement technology. Within the audio market, in the production and marketing of high quality power ampliers and sound systems for use both on tour and in static installations.
The success of the LA, DL and name synonymous with professional quality, high performance and utterly reliable power amps.
CAMCO has gained worldwide experience with professional
DX series power amps has made the
CAMCO specialises
CAMCO
1.2 Unpacking
Please unpack and inspect your new amplier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you the consignee may initiate a claim for shipping damage. CAMCO will be happy to cooperate fully as needed. Please save the shipping carton as evidence of damage for the shipper’s inspection.
Even if the amplier has arrived in perfect condition, save all packing materials so you will have them if you ever need to transport the unit.
1 WELCOME
CAMCO’s
of materials and technology but also most importantly in its highly skilled and motivated workforce, is one of the keys to its ongoing success.
With its all-new VORTEX sion in professional power amp construction. The seamless combination of groundbreaking technology with secure and proven elements is the hallmark of the new series.
Welcome to the new world of professional power ampliers –
commitment to research and development, seen not just in the area
power amp series,
CAMCO is pioneering a new dimen
WELCOME TO CAMCO!
NEVER SHIP THE AMPLIFIER WITHOUT THE ORIGINAL PACKING MATERIALS.
When shipping the VORTEX amplier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was origi
­nally packed at the factory.
-
USER MANUAL
VORTEX 3 QUADRO
P.7
Page 9
1.3 The Amplier
The VORTEX 3 QUADRO is a Class-H four channel power amplier with a power output of 750 W per channel / 4 load (1,5 kW in stereo / 2 or 8 load). These four channels are subdivided in two stereo ampliers A/B and C/D which can be independently set to stereo, Mono-Bridge or Parallel-Mono operation. This feature guarantes the most exibility of the VORTEX 3 QUADRO. It is supplied by Switched Mode Power Supplies (SMPS). These SMPS’s radically
1 WELCOME
reduce the weight and size (only 2U) of the amplier. Using SMPS, the 2 sym­metrical supply voltages of the power amplier are more stable than the power supplies used in conventional ampliers.
The VORTEX also uses three microprocessors for controlling and monitoring the power amp. Controlling a power amp designed for use in modern sound systems, has four main advantages over more traditional power amp systems:
Reduced Distortion
Improved Noise Characteristics
Integrated Remote Control
Indication of protection or failures by different LED sequences
The VORTEX has been designed as an intelligent and powerful product for performing specialised tasks within a complex audio system. Users can adapt the power amp to meet their specic audio requirements before use. Controls mounted on the front and the rear of the VORTEX allow access to the functionality.
Since some of the externally mounted controls have multiple functions, it is important that users should familiarise themselves with the entire range of con­trols and programmable features before using the power amp.
If you have questions about features of the VORTEX power amp that are not covered by the basic descriptions in this manual, CAMCO would be pleased to offer you further information. Alternatively, contact your dealer/distributor.
P.8
USER MANUAL
VORTEX 3 QUADRO
Page 10
1
2
4
3
6
5
7
2 FACILITIES
10
9
8
VORTEX 3 QUADRO – The Front
1 On LEDs (multifunctional) 2 Signal LEDs 3 Clip LEDs (multifunctional) 4 Volume Control – Channel A 5 Volume Control – Channel B 6 Volume Control – Channel C 7 Volume Control – Channel D
15
23
12
11
13 14
8 On/Off Switch 9 Enter-Switch (behind Front Panel) 10 CAI Status Indicator 11 Operating Mode Indicators ch. A/B 12 Operating Mode Indicators ch. C/D 13 Removable Air Filter System 14 Cooling Air Inlet Vents
24
VORTEX 3 QUADRO – The Rear
15 CAMCO Audio Interface (CAI) 16 Cooling Air Outlet Vents 17 Gain Selector ch. C/D 18 Mode Selector ch. C/D 19 Input Ground Lift Switch 20 Limiter Switch ch. A/B/C/D 21 Gain Selector ch. A/B 22 Mode Selector ch. A/B
16
25
17 18
26
23 AC Power Cable 24 SPEAKON Outlet ch. C/D 25 SPEAKON Outlet ch. A/B 26 XLR-Line Input ch. D 27 XLR-Line Input ch. C 28 XLR-Line Input ch. B 29 XLR-Line Input ch. A 30 Rating Plate
19
20
21
2827 29
22
30
USER MANUAL
VORTEX 3 QUADRO
P.9
Page 11
2.3 Factory settings
VORTEX 3 QUADRO ampliers are delivered with the following factory settings
2 FACILITIES
Front panel: Power switch Off Amplier is switched off
Rear panel:
Mode Channel C/D Stereo Limiter SpP Mode Channel A/B Stereo Gain Channel C/D 26 dB Input Ground Lift Grounded Gain Channel A/B 26 dB
P.10
USER MANUAL
VORTEX 3 QUADRO
Page 12
3.1 On/Off Switch
NOTE: This switch does NOT disconnect the amplier from mains.
The switch initiates start-up by activating the current limiting function. As soon as the power amplier is connected to the mains power supply, a voltage is supplied to both the line-lter and the fused input of the controllable rectier. Disconnecting the amplier from the main power supply can only be achieved by physically separating the amplier from the mains by pulling the mains plug. The mains plug therfore has to be freely accessible. Disconnect the mains plug from the mains during a lightning storm or when the amplier remains unused or un-supervised for a prolonged period of time. Alternatively, you can disconnect the amplier via an external all-pole disconnection from the mains. If a power cut occurs while the amplier is switched on, it will restart auto­matically once the power supply has been restored. All settings operation prior to the loss of power will be maintained.
3.2 Precautions
When mounting or connecting the amp always disconnect it from mains.
3.3 Mounting
Use four screws and washers when mounting the amplier to the front rack rails. For mobile use, the amplier should also be secured using the 19” mounting elements on the rear panel.
10,5 mm
76,2 mm
88,1 mm
411,0 mm
465,0 mm 442,0 mm
10,5 mm
437,0 mm
446,0 mm
76,2 mm
3 INSTALLATION
Amplier ist switched off. Amplier is switchen on
(On LEDs are lighting up).
USER MANUAL
VORTEX 3 QUADRO
P.11
Page 13
3.4 Cooling
Under normal operation of the power amp, overheating should never be a problem. The air is taken in from the front and out through the back, it is of course essential that while the power amp is running air is able to circulate around it freely. The temperature of the cooling air will depend on the immediate environment (e.g. an enclosed rack, direct sunlight) and on whether the front lter is clogged. If the amp is installed in a case, the open area at the back of the case must be at least 140 cm². This area should be in line with the amp.
3INSTALLATION
If this can not be achived a forced ventilation system has to be used.
3.5 Ground Lift
The input signal ground (pin 1 for all 4 XLRs) is tied to the ground potential in the mains supply. Opening the ground lift switch causes this connection to be broken. This allows ground loops that sometimes occur in practice to be elimi nated. The ground potential of the power amp and therefore of the loudspeaker outputs is independent of the switch setting and remains at the ground poten tial of the mains supply.
Removing or taping the mains connector ground is illegal and dangerous.
DO NOT REMOVE MAINS CONNECTOR GROUND
IT IS ILLEGAL AND DANGEROUS
3.6 Mode Indicators
On the front panel there are two pairs of yellow LEDs (A/B, C/D) to indicate the modes that are set to the ampliers A/B and C/D. In stereo mode none of them will be lit. In Parallel-Mono the (PM) LED and in Mono-Bridge the (MB) LED will be lit.
-
-
P.12
USER MANUAL
VORTEX 3 QUADRO
to Pin 1 of the XLRs
VORTEX 3 QUADRO
Example: A/B is set to stereo (no LED lit) and C/D to parallel-mono mode (PM lit).
in three channel operation,
Page 14
3.7 Mode Selectors
The switches AB MODE and CD MODE on the rear panel change the operating mode of the appropriate amplier (A/B , C/D). Moving one of these switches will shutdown the VORTEX 3 QUADRO and restart it in the new operating mode.
3.8 Basic Concepts
The VORTEX 3 QUADRO consists of two Stereo ampliers A/B and C/D. Both of them are capable to work independently in Stereo, Mono-Bridge or Parallel­Mono. Following you will nd a description about these modes for amplier A/B (in parenthesis the appropriate channels of amplier C/D).
3.8.1 Stereo Operation
Two fully independent amplier channels (normal operating mode).
Input Channel A(C)
Input Channel B(D)
ch A(C)
+
+
+
Z 4
ch B(D)
Z 4
3.8.2 Parallel-Mono Operation
Parallel operation of the two channels together.
Input Channel A(C)
ch A(C)
+
Z
2
res
+
ch B(D)
The output terminals of the two channels are congured in parallel using an internal relay. The (single) load is connected either to the output of channel A(C) or to that of channel B(D) (as if in stereo). While the total output of the amplier remains the same and the output voltage level is also the same as in stereo oper­ation, the minimum impedance that can be connected is reduced by half due to the fact that current capability is doubled. Only Channel A(C)-Input is active.
NOTE: For Parallel-Mono Operation, to prevent damage of one SPEAKON connector and to reduce loss of power because of contact or cable re­sistance, it is highly recommended to wire speaker loads using SPEAKON connector with all contacts connected.
3 INSTALLATION
USER MANUAL
VORTEX 3 QUADRO
P.13
Page 15
3.8.3 Mono-Bridge
One-channel mono bridged operation.
Input Channel A(C)
ch A(C)
+
1+
Z 8
3.9 Wiring
3.9.1 XLR Connection
Pin 1 Ground (or lifted via 15 Ohm resistor)
XLR:
Pin 2 Hot Pin 3 Cold
Always use symmetrical (balanced) shielded cable to connect the amplier.
P.14
ch B(D)
2+
3 INSTALLATION
The second channel processes the same input signal, but with reversed phase. The (single) load is connected between the two positive channel outputs (1+/2+) using a suitable connected SPEAKON connector. While the total output of the amplier remains the same, both the available output voltage and the minimum impedance that can be connected are doubled, as compared with stereo operation. Only Channel A(C)-Input is active Channel B(D) down to zero.
WARNING! In Mono-Bidge mode RMS output voltages are as high as 230 V. Wiring to the speaker loads must conform to NEC Class 3 safety standards or its equivalent that meets all national and local electric codes. All customer specic cables may only be manufactured by qualied suppliers/personnel. All cabeling or rewiring work must be carried out by qualied personnel.
USER MANUAL
VORTEX 3 QUADRO
– turn the volume on
To Ch. D
input stage
3
1
Input
Channel D
Input
Input Ground Lift in position:
Ground
grounded
Lift
To Ch. C
input stage
3
2
2
1
Input
Channel C
To Ch. B
input stage
3
1
Input
Channel B
To Ch. A
input stage
2
3
1
Input
Channel A
2
Page 16
3.9.2 SPEAKON Connection
The SPEAKON connectors are connected as shown below.
Right SPEAKON: Pin 1+ Channel A speaker signal (view from the rear) Pin 1 - Channel A speaker ground
Pin 2 + Channel B speaker signal Pin 2 - Channel B speaker ground
Left SPEAKON: Pin 1+ Channel C speaker signal (view from the rear) Pin 1 - Channel C speaker ground
Pin 2+ Channel D speaker signal Pin 2 - Channel D speaker ground
WARNING ! SPEAKON connectors marked with the lightning ashes indicate high vol­tages that are potentially life threating.
Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords.
Custom wiring should only be carried out by qualied personnel.
To prevent electric shock, do not operate the amplier with any of the conductor portion of the speaker wire exposed.
3 INSTALLATION
Input Channel A
Input Channel B
Input Channel C
Input Channel D
Right SPEAKON
Left SPEAKON
NOTE: For reasons of safety and performance, use only high-quality fully insu­lated speaker cables of stranded copper wire. Use the largest wire size that is economically and physically practical, and make sure the cables are no longer than necessary.
IMPORTANT: When connecting speaker cabinets in parallel, always use all the contacts in both SPEAKON connectors. If not, this may cause permanent damage to the connectors and considerably reduce performance.
USER MANUAL
VORTEX 3 QUADRO
P.15
Page 17
3.9.3 Four-Channel Operation
Four fully independent amplier channels give the opportunity of use in several applications, such as: multi-channel monitor systems, four channel reproduction, compact amplication in active 2- or 4-way systems ...
3 INSTALLATION
VORTEX 3 QUADRO
ch A
+
ch B
+
ch C
+
ch D
+
4
4
4
4
3.9.4 Three-Channel Operation
Three-Channel Operation is the choice for eg. stereo systems with subwoofer or compact amplication in active 3-way systems With its capability to be set to Mono-Bridge or Parallel-Mono the VORTEX 3 QUADRO gives the possibility to be adapted to the impedance of your sub­woofer .
3.9.4.1 Stereo / Parallel-Mono
With one amplier set to Parallel-Mono the VORTEX 3 QUADRO is capable to drive a two ohms load.
VORTEX 3 QUADRO
ch A
ch B
ch C
+
+
+
4
4
P.16
USER MANUAL
VORTEX 3 QUADRO
ch D
+
2
Page 18
3.9.4.2 Stereo / Mono-Bridge
If you have a high-impedance load you can set the appropriate amplier to Bridge-Mono operation.
3.9.5 Two-Channel Operation
With ampliers A/B and C/D set to mono modes you will nearly have a normal stereo amplier with the exception that you are able to choose either to drive minimum loads of 2 Ohms or 8 Ohms.
3.9.5.1 Parallel-Mono / Parallel-Mono
To drive two 2 Ohms loads just set the mode selectors to Parallel-Mono operation.
VORTEX 3 QUADRO
ch A
+
ch B
+
ch C
+
ch D
4
4
8
VORTEX 3 QUADRO
ch A
+
ch B
+
ch C
+
ch D
+
2
2
USER MANUAL
VORTEX 3 QUADRO
3 INSTALLATION
P.17
Page 19
3.9.5.2 Mono-Bridge / Mono-Bridge
With its mode selectors set to Mono-Bridge the VORTEX 3 QUADRO is able to control high impedances.
3.9.5.3 Parallel-Mono / Mono-Bridge
It is also possible to set one amplier to Parallel-Mono and the other to Mono­Bridge operation.
P.18
3 INSTALLATION
USER MANUAL
VORTEX 3 QUADRO
Vortex 3 Quadro
ch A
+
ch B
ch C
+
ch D
8
8
Vortex 3 Quadro
ch A
+
ch B
+
ch C
+
ch D
2
8
Page 20

CAMCO PRODUKTIONS- UND VERTRIEBS- GMBH
~ 
    

4.1 Precautions
Only connect the VORTEX amplier to an appropriate AC circuit and outlet, according to the requirements indicated in the second row on the rating plate.
Exemplary a rating plate of VORTEX 3 QUADRO
Power Supply Data:
Voltage Mains Frequency Current
VORTEX-3-QUADRO 100 V VORTEX-3-QUADRO 120 V 50/60 Hz 24 A 1800 W VORTEX-3-QUADRO 220 V 60 Hz 7,8 A 1070 W
NOTE: Even under normal conditions the mains current can reach levels up to 60 A (230 V) and 120 A (120 V), respectively; this could cause lamps to icker if connected to the same mains as the amp. The impedance of the AC circuit should be less than 0.157 Ohms to avoid icker according to EN61000-3-11. (Electromagnetic compatibility – sec tion 3 – 11: limits; limitation of voltage changes, voltage uctuations and icker in the public LV supply; equipment and appliances consuming more than 75 A current are subject to special conditions for connection/installation) If in any doublt, consult your local power provider. Never attempt to measure this impedance level with your ohmmeter. This may damage your meter and expose you to the risk of electric shock!
Power Consumption
4.2 Controls
4.2.1 Volume Control
Two microprocessor-controlled DCAs (Digital Controlled Attenuator) with a control resolution of 12 bits per channel is integrated into the signal path. This means that the signal is not subject to an A/D followed by a D/A conversion with associated losses. Each channel is governed by a linear potentiometer with 41 notched settings. These settings have been selected to correspond to human hearing characteristics (logarithmically) and therefore guarantee an optimal range of settings for practical applications. Each channel can be set individually except when operating in mono mode whereby only ChA (C) is active. Using an intelligent DCA control (Digital Controlled Attenuator) instead of the “conventional” VCA results in considerably reduced distortion as well as improved noise characteristics.
Set the volume to zero before turning on the amplier to prevent the occurrence of sudden high volume levels which may cause damage to your hearing and/or the speakers. The volume pots are also used to set the CAI-address. (See 5.2.2 CAI Address
Settings)
USER MANUAL
VORTEX 3 QUADRO
4 OPERATION
P.19
Page 21
4.2.2 Gain Selector
Two switches on the rear of the VORTEX allows the maximum amplication attainable to be set directly in the input stage of each amplier (A/B, C/D).
The VORTEX amplier has a 26 dB and 32 dB voltage gain setting along with a
4 OPERATION
1,4 V sensitivity setting.
Model 26 dB 32 dB 1,4 V
VORTEX 3 QUADRO
4.2.3 Limiter Switch
This switch is located at the rear of the VORTEX. It allows you to set the mode of the limiter. This limiter affects both channels in both ampliers There are three modes: (See 4.4.1 Clip Limiter and 4.4.4 Speaker Protect Limiter)
4 / 750 W 8 / 450 W
Right position:
Clip Limiter: On Speaker Protect: On
Middle position:
Clip Limiter: Off Speaker Protect: On
Left position:
Clip Limiter: Off Speaker Protect: Off
2,75 3,01
1,38 1,51 32,64
4.3 Indicators
4.3.1 On LEDs (multifunctional)
Under normal operation, after the amp has started, the green power LEDs are permanently lit. A variety of different sequences of ashing LEDs are used to indicate other operating states and errors in one of the channels of the power amp. (See 6.1 On LED Flashing Sequences)
P.20
USER MANUAL
VORTEX 3 QUADRO
Page 22
4.3.2 Signal LEDs
The green signal LED is illuminated when the voltage level at the output reaches approx. 4 V; this corresponds to a power of approx. 4 W at an impedance of 4 Ohms.
The intensity of the green light is dened by the current passing through the output stage of each channel (lowest brightness is proportional to approximately 1 A, the maximum brightness reects the maximum output current). The red colour indicates the amount of signal clipping in each respective channel. If the green LED (current indicator) and red LED (clipping indicator) light up simultaneously, the Clip LED is yellow.
4.3.3 Clip LEDs (multifunctional)
The clip LEDs are bi-coloured: green/red. Each colour indicates a different status.
If the amplier is overdriven for prolonged periods, the Clip LED will appear red to alert the user more effectively (the green component of the LED is switched off). Monitoring the output current and clip via the LEDs can aid the detection of incorrectly wired components and faults in the loudspeakers at an early stage. (See 6 Troubleshooting)
4.4 Power Amp Protection Systems
4.4.1 Clip Limiter
If the power amp is overdriven, the clip detection circuit triggers the micro­processor. The processor reduces input signal level by controlling the DCA. The strategy is implemented in software. For sinusoidal input signals the microprocessor limits the input signal in such a way that non-linear distortions of the signal never exceed 1 %. The clip limiter can work on each channel independently (except in mono­operation). To disable the Clip Limiter, see 4.2.3 Limiter Switch.
4.4.2 Under Impedance Limiter
As a result of incorrectly connected or defective loads, under impedance or even short circuits may be presented to the power amp channels. In order to detect an under impedance, the microprocessor calculates the result­ant impedance. If an impedance of less than 2,66 ohms/channel is detected, the microprocessor limits the signal to the power amp until a subsequent measure­ment indicates that impedance has risen to a safe level. Whenever the under
USER MANUAL
VORTEX 3 QUADRO
4 OPERATION
P.21
Page 23
P.22
impedance limiter is active, the corresponding channel’s On LED is turned off.
(See 6 Troubleshooting)
4.4.3 SOA Protection
Whenever the power transistors leave their Safe Operation Area (SOA), the SOA-protection in stereo mode switches back the current rail of the respective power stage. In mono modes the rails of both channels of one amplier are switched back.
4 OPERATION
4.4.4 Speaker Protect Limiter
Whenever the SOA protection of the power amp switches back the current rail there could be a small clipping at the output; but the microprocessor is also triggered by this protection and will reduce the signal level immediately to minimise the effect.
The user can decide either to use Speaker Protect or not. If you use this amp for low frequencies (bass / Sub bass) and you want to squeeze the absolute maximum out of it, Speaker Protect can be switched off. For all other applications (e.g. Full Range) it’s recommended to keep Speaker Protect switched on.
4.4.5 DC Protection
Each output of the power amp is constantly monitored for persistent DC voltage levels. If the 3 V thresholds are exceeded at any of the outputs, main SMPS will shut down and the channel at that output will be automatically disconnected. The microprocessor performs a sophisticated strategy to locate the cause of DC. If short-term DC is detected, the amplier will recover and continue to operate. DC can be located in the output stage, driver stage or at the input of the amplier.
Output Stage
When a DC voltage is located at an output stage, the main SMPS remains switched off. The On LEDs will show a ash sequence corresponding to this malfunction. (See 6 Troubleshooting)
USER MANUAL
VORTEX 3 QUADRO
Driver Stage
When a DC voltage is located at the driver stage only the defective channel’s output stage and the DCA are muted. The other channel continues to work. The On LED of the defective channel will indicate the malfunction by starting the relevant ash sequence. (See 6 Troubleshooting)
Amplier Input
When DC is located at the input stage only the DCA of the affected channel is muted. (The other channels continue to operate normally). If the DC signal at the input vanishes the microprocessor will de-mute the affected channel and the amplier will work as usual again.
4.4.6 DC Servo
To prevent DC Offset at the speaker output the VORTEX is tted with two DC Servos per channel. (Hence there are no capacitors in the signal path!)
4.4.7 Over Current Protection
Over current is permanently controlled in the output stage. There are two limi­ting levels of over current depending on output voltage. These limits will be set automatically. This improves reliability without degrading sound quality when driving complex loads.
4.4.8 Thermal Protection
The microprocessor uses several sensors in the amp in order to ascertain tem­perature data. If the microprocessor detects a temperature of more than 85 °C at the heat sinks, the input signal on that channel is reduced. If the temperature exceeds 100 °C, the main SMPS is switched off. The On LED of the overheated channel will start a blinking-sequence.
(See 6 Troubleshooting)
Page 24
4.5 Mains Protections
4.5.1 Inrush Current Limitation
Within 2 seconds of the VORTEX being switched on, the inrush current limiter will increase mains current from nearly zero to nominal value. This value depends on program material, output level and speaker loads.
4.5.2 Mains Over Voltage Detection
Mains over voltage detection is always operative. When the mains voltage exceeds approx. 267 V (230 V operation) or 134 V (120 V operation), the amplier will be switched off. The system will try to start in intervalls and will return with a soft start when the regular mains voltage returns.
4.5.3 Mains Failure Detection
Mains failure detection is always operative. When the mains supply is inter­rupted for about 2 mains cycles, the amplier will be switched off. When the mains voltage returns to a normal value, a soft start occurs.
4.5.4 Fuse Protection
The average mains current can peak temporarily, depending on the load impedance and type of signal, at values signicant higher than the nominal value allowed by the fuse protection. Continuous monitoring of the fuse protection status allows the conditions that would trigger the fuse protection to be predicted. In order to avoid shut-down of the amplier due to current overload, the amplitude of the input signals will be limited and by hard overloads the amp will be muted for the time. The limitation of the input signal allows a 6 kW VORTEX power amplier to be operated reliably from a mains power supply of 230V / 16 A (120 V / 30A).
4.6 Main SMPS Protections
4.6.1 Over Current Protection
Main SMPS (Switched Mode Power Supply) transformer current of your VORTEX is continuously monitored. If over current occurs, the main SMPS immediately stops working. Should there be an internal failure, this feature prevents other parts being damaged.
4.6.2 Thermal Protection
The temperature of the main SMPS transformer of your VORTEX is permanently monitored. If the temperature exceeds 85 °C, the microchip reduces the input signals of both channels. If the temperature surpasses 100 °C, the main SMPS is switched off. The On LEDs will start a blinking sequence corresponding to this malfunction. (See 6 Troubleshooting)
4.7 Fans
The fans mounted in your VORTEX operate permanently, but as long as the temperature remains below 40 °C, they run at their slowest speed and can hardly be heard. The highest detected temperature from either channel controls the speed of the fans. Above 40 °C the speed is increased until it reaches its maximum value.
4 OPERATION
USER MANUAL
VORTEX 3 QUADRO
P.23
Page 25
4.8 Filter Cleaning
The air intake on the front of your VORTEX is tted with a removable lter system. If the lter becomes clogged, the unit will not cool as efciently as it should and may result in reduced output levels.
4 OPERATION
VORTEX Filter Assembly
1 Clip Apertures 2 Injection Moulded Cradle 3 Foam Filter 4 Injection Moulded Surround 5 Injection Moulded CAMCO Badge
For changing the lter, no tools are required: rst, gently slide the whole plastic lter assembly a few millimetres to the left and lift it from the front panel. Next, beginning on one of the long sides, carefully unclip the moulded surround (4) from the cradle (2) and then carefully pull the CAMCO badge (5) out of the four fastening holes with both hands. Remove the foam lter (3) and clean it with a mild dishwashing detergent and warm water. Once dry, replace the foam lter carefully into the cradle and repeat the dismantling procedure in reverse. Insert the ve pins on the lter frame into the clip apertures (1) and slide the lter carefully to the right to secure.
Spare lter assembly’s may be ordered from your dealer/distributor.
3
4
5
1
2
P.24
USER MANUAL
VORTEX 3 QUADRO
Page 26
5.1 CAI (CAMCO Audio Interface)
CAI is a bus system, in which all signicant device functions can be monitored externally and remotely controlled using a master PC. Up to 99 devices can be controlled in parallel in each phase of the bus system, which simply consists of a two-core insulated cable. The master can serve several phases for larger appli cations. For more information, please contact your dealer or distributor.
CAI allows:
To control the output-level of each Channel independently
(exception: mono modes, only Channel A(C) is affected)
To mute each channel independently
(exception: mono modes, only Channel A(C) is affected)
To switch the
To monitor temperature, output-signal, clip, output-current.
into STANDBY (and back again)
VORTEX
NOTE: Ensure you return both pots to their original position after address selection is complete, otherwise the amplier will change its volume level to the new pot positions!
-
Briey press the ENTER-Switch
. This push button switch can be accessed through the 3 mm hole in the front panel located between the On/Off switch and the LEDs.
5 OPTIONS
5.1.1 Wiring
to your CAI system use a fully-wired telephone-type
To connect the
VORTEX
cable with RJ12 connectors. For longer distances use high grade cable like for RS485, DMX512 for AES/EBU digital audio. You can chain several
VORTEX
ampliers using the second CAI connector on each amplier. A linear network topology is recommended with 100 Ohm termination at its end. Please refer to RS485 specications.
5.1.2 CAI Address Settings
The VORTEX 3 QUADRO uses two addresses to communicate with the master PC. You only select the address for amplier A/B, the address of amplier C/D is automatically set to address for amplier A/B plus one. The CAI address selection procedure will not affect the operation of the
but whilst this procedure is active, the volume cannot be adjusted by
VORTEX
using the pots.
CAI LED
ENTER-Switch
Example of LED sequences for different address settings:
Adresses (A/B)/(C/D)
01/02 (factory settings)
25/26
On-LED Channel A
0* ash
2* ashes then short pause
After briey pressing the Enter-Switch
=>
1* ash then short pause
5* ashes then short pause
the actual address of amplifier A/B will be
=> Units
Channel B
On-LED
Tens
displayed by the On LEDs of ChA and ChB. The address of amplier C/D is not shown.
Flashing of On LED channel A indicates the tens
Flashing of On LED channel B indicates the units of the address of amplier A/B
USER MANUAL
VORTEX 3 QUADRO
P.25
Page 27
5 OPTIONS
USER MANUAL
VORTEX 3 QUADRO
P.26
These sequences are repeated for 30 seconds (timeout). Then the On LEDs return to their normal function.
To change CAI addresses, turn the appropriate volume potentiometer to the required address of amplier A/B (Volume Pot Ch A => T Ch B => U
nits). The address of amplier C/D is automatically set to address for
ens, Volume Pot
amplier A/B plus one.
To adjust the address you can use the scale markings of the potentio­meters. You will nd the digits 0,1,...,9 on the 10 scale spacing .
4
5
3
6
2
4
5
1
3
6
2
1
4
5
3
6
2
1
4
5
3
6
2
1
9
0
7
8
9
0
7
8
7
8
9
0
7
8
9
0
The current selected address of amplier A/B will be immediately displayed but
NOT
automatically stored or activated! After each turn of pot you have another 30 seconds to timeout. You can leave this procedure without saving the new addresses by briey pressing the Enter-Switch or waiting for timeout (as described above). To store and activate the new addresses you have to press the Enter-Switch for 3 seconds. These new addresses are stored in an EEPROM, which holds the information even if the amp is subsequently disconnected from mains. Be sure to set the CAI-Master-PC to these new addresses. If not, the communication will be interrupted.
5.1.3 CAI Status Indicator
This green LED indicates the presence of communication between PC and the amp.
Page 28
6.1 On LED Flashing Sequences
When switching on the amp the On LEDs ash twice accompanied by a ash of Clip LEDs. This is normal for the ‘Start’ sequence of the VORTEX.
When switching off the amp the On LEDs ash several times followed by a ash of Clip LEDs. This is normal for the ‘Shut Down’ sequence of the VORTEX. (It is the same as the loss of the mains voltage.)
In the following table you will nd the possible LED sequences of the On LEDs:
Operating Status
Normal (no failure) Permanently lit
Power Fail
(i.e. switch off)
High Temperature
signal attenuation
Over Temperature:
main SMPS off
DC
reason unknown
DC
input-signal-faul
DC
fault in driver stage
DC
output stage defect
Output Stage Defect without DC
Main SMPS off
(unless Hi Temp/Power Fail)
LED Sequence ( ) = ash, (__) = off
Description of repeated sequences
Short 50 ms ash + 950 ms pause
750 ms ash + 250 ms pause
250 ms ash + 750 ms pause
250 ms ash + 250 ms pause
3 * ashing + 0.5 s pause
4 * ashing + 0.5 s pause
5 * ashing + 0.5 s pause
6 * ashing + 0.5 s pause
2 * ashing + 0.5 s pause
Examples of LED Sequences
LED sequence: Ch1:
Ch2: Ch3: Ch4:
Failure: Ch1: high temperature with signal attenuation
Ch2: normal operation Ch3: normal operation Ch4: normal operation
LED sequence: Ch1:
Ch2: Ch3: Ch4:
Failure: Ch1: DC, output stage defect
Ch2: main SMPS off Ch3: main SMPS off Ch4: main SMPS off
6 TROUBLESHOOTING
USER MANUAL
VORTEX 3 QUADRO
P.27
Page 29
P.28
6.2 Problem: No Sound
Indication: On LEDs not lit
Indication: On LEDs lit
Indication: On LEDs lit
6 TROUBLESHOOTING
Indication: On LED(s) sequence
The amplier is in protective muting. Refer to On LED ashing sequences table to nd out the cause for the mute.
6.3 Problem: No Sound or Sound Is Too Low
Indication: On LED not or sporadically lit
Under Impedance Limiter is active. The load impedance is abnormally low or shorted.
USER MANUAL
VORTEX 3 QUADRO
Clip LEDs not lit
Check AC plug.
Conrm that AC outlet works by plugging in another device.
Signal LED not lit
Make sure the signal source is operating and try another cable.
Check position of Volume Pots.
Signal LEDs responding to signal level
Check the speaker wiring for breaks.
Try another speaker and cable.
Overheating will cause protective muting.
Check for proper ventilation. If the fans aren’t running the amplier
requires servicing.
Signal LED not lit Clip LED lit
Unplug each speaker one-by-one. If the On LED indicates normally when
you disconnect a cable, that cable or speaker is shorted.
Take care not to use too many speakers in parallel, which would result in an
impedance that is too low for normal operation!
Indication: On LED(s) sequence
Please refer to the On LED ashing sequences table to nd out which protection is active. High temperature will cause an attenuation of output level! DC will cause the amp to mute or shut down.
Switch off the VORTEX and unplug the source from the amp’s input to
prevent DC entering the amp via the signal source. Then switch on the VORTEX. If the On LED shows the same sequence, the amp will need to be serviced by a qualied technician.
All other On LED sequences that shut down or mute the VORTEX indicate a serious internal fault. At this point, turn the VORTEX off, remove AC power and have the amplier serviced by a qualied technician.
6.4 Problem: No Channel Separation
Check the mode indicators on the front panel and make sure the mode
selector on the rear panel is in the stereo-position.
Make sure other equipment in the signal path such as mixers and preamps
are set for stereo, not mono.
6.5 Problem: Distorted Sound
Indication: On LED lit
Signal LED responding to signal level Clip LED lit only green
A faulty speaker or a loose connection could cause this. Try another
speaker and check the wiring.
The signal source might be clipping. Keep the VORTEX volume pots at
least halfway up so that the source does not have to be overdriven.
Keep the VORTEX volume pots at least halfway up and try changing input
sensitivity from 1,4 V to 32 dB or 26 dB with the gain selector on the rear.
Page 30
6.6 Problem: Hiss
Unplug the amplier input to conrm that the hiss is coming from the
source or from a device upstream. Erratic or popping noises indicate an electronic fault in the offending unit.
To keep the noise oor low, operate the primary signal source at full level,
without clipping.
Avoid boosting the signal further between the source and the amplier.
6.7 Problem: Squeals and Feedback
Microphone feedback should be controlled with mixer controls. If noise
continues to build up with no microphone gain, there is a serious fault in the signal processors or cables. Working in succession from the signal source towards the amplier and check each device in the signal path by reducing its gain or by unplugging it.
6 TROUBLESHOOTING
USER MANUAL
VORTEX 3 QUADRO
P.29
Page 31
VORTEX 3 Quadro
1 kHz, THD < 0,1 % , in mono-bridge mode
Output Power
1 kHz, THD < 0,1 %, in parallel-mono mode
1 kHz, THD < 1 %, all channels driven
Duration limited by fuse / thermal protection for RL < 8
in stereo mode or RL < 16 in mono-bridge mode.
7 SPECIFICATION
Measurement at 2 without preconditioning (EN 60268-3)
Signal to Noise-Ratio
20 Hz - 20 kHz, 8 load, unweighted
A-weighted
Power Consumption @ 230 V
(all channels driven)
Multiply currents by 2 for 120 V
2)
2 x 1500 W / 8 2 x 900 W / 16
2 x 1500 W / 2
2 x 900 W / 4
4 x 750 W / 4 4 x 450 W / 8
Circuitry Bipolar, Class H 2-step
high efciency circuit
>103 dB
>106 dB
Typical1)Max
Idle 1,4 A /
67 W
3,9 A /
16
385 W
5,6 A /
8
638 W
7,8 A /
4
1070 W
1)
1/8 of max Output Power with pink noise to represent typical music signal
10,1 A / 1490 W
17,1 A / 2650 W
28,1 A / 4440 W
max. rated Output Power (see above)
2)
P.30
USER MANUAL
VORTEX 3 QUADRO
Page 32
Frequency Response 20 Hz - 20 kHz ± 0,15 dB
Input Impedance 40 k balanced Voltage Gain selectable: 26 dB, 32 dB, or 1,4 V input sensitivity Protection Circuits inrush-current limitation, temperature monitoring of transformers and heat-sinks,
Limiter switchable clip- and speaker protect limiter Fan 2 temperature dependent speed-controlled axial fans Ground Lift input ground lift switch on back panel Indicators LEDs for On, Signal, Clip, indicating additionally Output Current and faults
Input Connectors 3-pin XLR, male and female per channel, pin 2 = inphase Output Connectors one 4-pole SPEAKON connector for each output channel
Modes of Operation Stereo, Mono-Bridge and Parallel-Mono Options Extended User Interface / E.U.I. – modules for any kind of EQ THD+N (typical) < 0,01 %
20 Hz - 10 kHz, 8 load, 3 dB below rated power
SMPTE (typical) < 0,01 %
20 Hz - 20 kHz, 8 load, 3 dB below rated power
Damping Factor > 400
8 load, 1 kHz and below
Dimensions (WxHxD) 483 x 88,9 x 420 mm (19”, 2U) Net Weight 12,4 kg Shipping Dimensions (WxHxD) 600 x 205 x 600 mm (0,074 m3) Shipping Weight 15 kg
8 load, 1 dB below rated power
output DC protection, power transistor SOA protection, output over current protection, under impedance limiter, intelligent mains fuses protection
for example like DC and High Temp
(bi-amping possible)
7 SPECIFICATION
We reserve the right to make technical alterations without prior notice
USER MANUAL
VORTEX 3 QUADRO
P.31
Page 33
+27
+26,5
+26
+25,5
+25
+24,5
dBr
+24
+23,5
+23
+22,5
+22
8 MEASUREMENTS
+21,5
+21
10 20 50 100 200 500 1k 2k 5k 10k 20k 50k 100k
Hz
Figure 8.1
Gain vs. frequency
(Measurements of a typical performance)
+180
+135
+90
+45
+0
deg
-45
-90
-135
-180 10 20 50 100 200 500 1k 2k 5k 10k 20k 50k 100k
Hz
Figure 8.3
Phase vs. frequency
(Measurements of a typical performance)
P.32
-10
-20
-30
-40
-50
dBr
-60
-70
-80
-90
-100
-110
20 50 100 200 500 1k 2k 5k 10k 20k
USER MANUAL
VORTEX 3 QUADRO
Hz
Figure 8.2
Channel separation vs. frequency
(Measurements of a typical performance)
-20
-30
-40
-50
-60
dB
-70
-80
-90
-100
-110
-120 20 50 100 200 500 1k 2k 5k 10k
Hz
Figure 8.4
THD + N vs. frequency (BW 22 kHz), 3 dB below clip, 8 Ohms
(Measurements of a typical performance)
Page 34
300m
200m
100m
50m
V
20m
10m
5m
1k
800
600
V
400
200
2m
20 50 100 200 500 1k 2k 5k 10k 20k
Hz
Figure 8.5
Output Impedance vs. frequency @ 1 Amp RMS injected current
equivalent 11 m + 2,1 µH (Measurements of a typical performance)
-20
-30
-40
-50
-60
-70
dB
-80
-90
-100
-110
-120 100u 200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2 5
Vrms
Figure 8.6
THD+N @ 1 kHz, 4 load vs. input voltage
(Measurements of a typical performance)
0
20 50 100 200 500 1k 2k 5k 10k 20k
Hz
Figure 8.7
Damping factor into 8 vs. frequency
equation: damping factor = loaded impedance / amplier output impedance
(Measurements of a typical performance)
-40
-50
-60
-70
-80
dBr
-90
-100
-110
-120 20 50 100 200 500 1k 2k 5k 10k 20k
Hz
Figure 8.8
CMRR
(Measurements of a typical performance)
VORTEX 3 QUADRO
USER MANUAL
8 MEASUREMENTS
P.33
Page 35
P.34
dB
8 MEASUREMENTS
dB
USER MANUAL
VORTEX 3 QUADRO
-20
-40
-60
-80
-100
-120 100u 200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2 5
Vrms
Figure 8.9
CCIF difference frequency method (10,5 kHz und 11,5 kHz) @ 8
vs. input level (Measurements of a typical performance)
-20
-30
-40
-50
-60
-70
-80
-90
-100 100u 200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2 5
Vrms
Figure 8.10
SMPTE Intermodulation distortion (60 Hz und 7 kHz) @ 8
vs. input level (Measurements of a typical performance)
Channel A
Channel B
Channel C
Channel D
Page 36
1000
952
785
750
570
Watt
500
250
0
4
Impedance (Ohms)
475
306
265
8
16
Figure 8.11
VORTEX 3 Quadro (Measurements of a typical performance)
Distortion limited output power (0,1 %)
Peak power
Peak power
Distortion limited output power (0,1 % THD)
USER MANUAL
VORTEX 3 QUADRO
8 MEASUREMENTS
P.35
Page 37
9.1 Summary Of Warranty
guarantees the VORTEX amplier to be free from defective material
CAMCO
and/or workmanship for a period of three years from the date of sale. Provided that the amplier is returned to your dealer/distributor in a factory pack with a copy of the proof of purchase, i.e., sales receipt, products under this warranty when a defect occurs under normal installation and use.
This warranty provides that examination of the returned product must indicate, in our judgment, a manufacturing defect.
9.2 Items Excluded From This Warranty
is not liable for any damage caused by shipping accidents, misuse,
CAMCO
abuse, operation with incorrect AC voltage, operation with faulty associated equipment, modication, or alteration without prior factory approval, service by an unauthorised service center, and normal wear and tear. Ampliers on which
9 WARRANTY INFORMATION
the Serial Number has been removed or defaced are not eligible for warranty service.
9.3 What CAMCO Will Do
CAMCO (or its appointed agent) will rectify any defect, regardless of the reason for failure (except as excluded), by repair, replacement, or refund, as it sees t.
CAMCO
will repair faulty
9.4 How To Obtain Warranty Service
You must notify your dealer/distributor of your need for warranty service. All components must be shipped in a factory pack.
9.5 CAMCO’s Product Improvement
Due to CAMCO’s policy to continuous product improvement, specication is liable to change without notice. Please consult your dealer/distributor or for clarication if necessary.
CAMCO direct
P.36
USER MANUAL
VORTEX 3 QUADRO
Page 38
PLEASE ENCLOSE THIS COMPLETED FORM WITH THE AMPLIFIER
DO NOT SEND SEPARATELY
10.1 Owner’s Information
Company Name: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Contact: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Address: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Telephone: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Facsimile: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ eMail Address: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Model: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Serial Number: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Purchase Date: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
10.3 Expired Warranty
If the warranty has expired, payment will be:
Cash/Cheque
VISA
MasterCard
10.4 Shipping Address
To transport the amplier, the original packing materials must be used. Please return the amplier to the following address or your nearest CAMCO appointed distributor.
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen, Fischpicke 5, D-57482 Wenden, Germany
10.2 Nature Of Problem
Please describe the conditions that existed when the problem occured and what attempts were made to correct it: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Other equipment in your system: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Our web site: www.camcoaudio.com provides a complete list of CAMCO dealers/distributors.
USER MANUAL
VORTEX 3 QUADRO
10 SERVICE INFORMATION
P.37
Page 39
11 Maintenance Information
Cleaning and servicing the inside of the aplier must never carry out by unquali­ed personnel. The amplier must never be opened by unqualied personnel.
Cleaning and servicing work on the inside of the amplier must only be carried out by qualied personnel.
Qualied personnel is dened as a person who has gained specialised relevant knowledge of electronic engineering through education, training and experi­ence and who has sufcient knowledge of all relevant governmental work safety regulations to be in a position to judge the safe functioning of power ampliers based on technical rules according to IEC 60065. (IEC 60065 (Din EN 60065) Safety Requirements for Audio, Video or simlar Elec­tronic Appliances)
In order to guarantee the safe functioning of the amplier, it has to be checked regularly, depending on its application but at least once a year, by a properly qualied person. Advice on how to carry out these checks can be found in DIN VDE 0702-1 Safety Checks for Electronic Appliances.
An amplier that is considered to be unsafe must be labelled accordingly and stored in a safe place to prevent this amplier being used mistakenly.
12 Decomissioning
During the decomissioning process of the amplier, all legally prescribed rules and procedures must be adhered to.
11 MAINTENANCE INFORMATION/12 DECOMISSIONING
USER MANUAL
VORTEX 3 QUADRO
P.38
Page 40
CAMCO Produktions- und Vertriebs- GmbH
für Beschallungs- und Beleuchtungsanlagen
Mailing Address:
Fischpicke 5
D-57482 Wenden
Germany
Telephone:
+49 (0) 27 62/4 08- 0
+49 (0) 27 62/4 08- 10
www.camcoaudio.com
postmaster@camco.de
Facsimile:
Internet:
Email:
USER MANUAL
VORTEX 3 QUADRO
COMPANY INFORMATION
P.39
Page 41
P.40
USER MANUAL
VORTEX 3 QUADRO
Page 42
www.camcoaudio.com
Loading...