The CIG name, the CIG logo, and all CIG product names are trademarks of Cambridge Industries
Group Co. Ltd (CIG). All other brand and product names are trademarks of their respective holders.
Specifications, products, and products names are subject to change without notice.
This document may not be reproduced in whole or in part without the express written permission of
CIG. This document contains confidential, proprietary information belonging to CIG, and may not be
used or disclosed except in accordance with applicable agreements.
Performance figures and data quoted in this document are typical and must be specifically confirmed
in writing by CIG before they become applicable to any particular order or contract. The company
reserves the right to make alterations or amendments to the detailed specification at its discretion.
Copyright 2006, 2007 Cambridge Industries Group Co. Ltd. All rights reserved.
Document History
Part Number Summary of Changes
-01, Rev. A Initial release
-02, Rev. B Bug fixing
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd I
ONT G-25E Hardware Installation Manual
Product Information
To learn more about this product or CIG, contact your local sales representative or contact CIG
Marketing at:
Address:
Hong Kong
25th Floor, Jardine House, 1 Connaught Place
Hong Kong, PRC
Phone: +852 2827 1778
Shanghai
Building 4, 3/F, Block D
889 Yishan Road
Shanghai 200233, China
Phone: +86 21 6121 3299
Fax: +86 21 6121 3277
Email: info@cambridgeig.com
Web URL: http://www.cambridgeig.com
Ordering
To order CIG components and documents, contact your local sales representative, or contact
CIG at the address, telephone, fax number or e-mail address listed above.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd II
ONT G-25E Hardware Installation Manual
Technical Support
CIG offers technical support 24 hours a day, 7 days a week. To contact the CIG technical
assistance center, use one of the following methods:
NOTE: For urgent support requests, please contact CIG by telephone. Delays caused by email may result in a longer response time.
Telephone: +86 21 6121 3299
Email: support@cambridgeig.com
When you contact CIG, please have the following information ready:
z Product model name, part number, and serial number
z List of system hardware and software, including version
z Diagnostic error messages, if any
z Details about recent configuration changes, if applicable
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd III
ONT G-25E Hardware Installation Manual
Compliance with CE Marking Certification (Class B)
The equipment was tested and found to comply with EN 60950-1:2001. The equipment is
tested and only used with power adaptor included in the package.
The equipment complies with the requirements according to the following standard:
ETSI EN 300 386 V1.3.3: 2005 Electromagnetic compatibility and radio spectrum Matters
(ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC)
requirements
EN 61000-6-1:2001: Electromagnetic compatibility (EMC) — Part 6-1: Generic standards
Immunity for residential, commercial and light-industrial environments.
EN 61000-6-3:2001: Electromagnetic compatibility (EMC) — Part 6-3: Generic standards —
Emission standard for residential, commercial and light-industrial environments, which refers to
the following basic standards:
EN 55 022+A1:2000+A2:2003: Information technology equipment – Radio disturbance
characteristics Limits and methods of measurement.
EN 61000-4-2: 1995/+A1:1998/+A2:2001: Electromagnetic Compatibility (EMC) – Part 4:
testing and measurement techniques – section 2: electrostatic discharge immunity test
EN 61000-4-3: 2002/+A1:2002: Electromagnetic Compatibility (EMC) – Part 4: testing and
measurement techniques – section 3: radiated, radio frequency, electromagnetic field immunity
test
EN 61000-4-4: 2004: Electromagnetic Compatibility (EMC) – Part 4: testing and measurement
techniques – section 4: electric fast transient/burst immunity test
EN 61000-4-5: 1995/+A1: 2001: Electromagnetic Compatibility (EMC) – Part 4: testing and
measurement techniques – section 5: surge immunity test
EN 61000-4-6: 1996/+A1:2001: Electromagnetic Compatibility (EMC) – Part 4: testing and
measurement techniques – section 6: immunity to conducted disturbance, induced by radio
frequency field.
EN 61000-4-11:2004: Electromagnetic Compatibility (EMC) – Part 4: testing and
measurement techniques – section 11: voltage dips, short interruption and voltage variations
immunity test
EN 61000-3-2:2000/+A2:2005: Limits for harmonic current emissions (equipment input
current <=16A per phase)
EN 61000-3-3:1995/+A1:2001/+A2:2005: Limitation of voltage fluctuations and flicker in
low-voltage supply systems for equipment with rated current <=16A
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd IV
ONT G-25E Hardware Installation Manual
Table of Contents
About This Document
Purpose ___________________________________________________________________________ VI
Intended Audience _________________________________________________________________ VI
Chapter Overview __________________________________________________________________ VI
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd V
ONT G-25E Hardware Installation Manual
About This Document
Purpose
This guide describes how to install the CIG optical network termination unit (ONT) at the
customer premises.
Intended Audience
This document is intended for technicians responsible for:
z Unpacking and mounting the ONT and power supply
z Connecting the ONT to the PON network
z Connecting services to the ONT
Chapter Overview
This manual is organized as follows:
Chapter 1: Product Description
Provides an introduction to the ONT including physical, electrical, environmental and optical
specifications. Compliance information is also provided.
Chapter 2: Safety
Provides electrical, electrostatic, and laser safety information; fiber optic cable handling
techniques are also discussed.
Chapter 3: Installing the ONT
Describes installation procedures including site preparation, unpacking and mounting the ONT,
connecting power and fiber optic and cables, connecting service cables, activating the ONT, and
verifying the installation.
Chapter 4: Troubleshooting
Explains ONT LED behavior and provides basic troubleshooting guidelines.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd VI
ONT G-25E Hardware Installation Manual
1. Product Description
1.1 Introduction
Optical Network Terminal (ONT) model G-25E is an ITU-T G.984 compliant device that receives
voice, data, and video traffic in the form of optical signal from the service provider’s passive
optical network (PON) and transmitted it to the desired format - voice, data, or video - at
residential or business premises.
Upstream traffic is likewise trans mitted to the PON network via the fiber optic cable. A sin gle
optical fiber carries both upstream and downstream traffic.
1.2 Services
Equipped with ITU-T G.984 compliant 2.5G Downstream and 1.25G Upstream GPON UPLINK
interface, ONT G-25E supports the full Triple Play of servic es including voi ce, video (IPTV/ VOD),
and high speed internet access.
1
ONT G-25E is equipped with the following service interfaces
z Four 10/100 Base-T Ethernet ports for high speed internet access and IPTV/VOD services
z Two POTS (VoIP) service ports for voice services
ONT G-25E has built-in capability for remote management like supervision, monitoring, and
maintenance.
:
1.3 Features
The ONT incorporates the following features:
zSingle fiber GPON interface with 1244Mbit/s upstream and 2488Mbit/s downstream data
rates
z Advanced data features such as VLAN tag manipulation, classification, and filtering.
z Traffic classification and QoS capability
z Analog Telephone Adapter (ATA) function integrated based on SIP (RFC3261), with various
CLASS services supported - Caller ID, Call Waiting, Call Forwarding, Call Transfer, etc.
z5 REN per line
2
z Multiple voice Codec
z Rich set of LED indications for alarming and maintenance
1
Some customized models may only provide a subset of service interfaces mentioned in this manual, for example, only four 10/100
Base-T Ethernet ports are provided.
2
These services may be unavailable within a specific carrier network and may require additional subscription.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 1
ONT G-25E Hardware Installation Manual
1.4 Specifications
ONT physical, electrical, optical, and environmental specifications and compliance information
are listed in the following tables.
Dimensions 127mm (height) by 170mm (width) by 39mm (depth)
Weight 0.4 KG excluding power adaptor
GPON interface SC/APC angled optical co nnector
POTS
interface
Ethernet
interface
RJ-11 connector
RJ-45 connector
Table 1 Physical specification
Input Power +12V DC power input
Power Supply AC power supply with included power adapter
Power
Consumption
< 7.5W
Table 2 Electrical specification
Temperature 0 ~ 40° C
Humidity 5 ~ 85% relative humidity
Table 3 Environmental specification
PON ITU-T G.984.1, G.984.2, G.984.2 amd1, G.984.3, G.984.4, G.983.2
EMC ETSI EN 300386, EN 55022 (Class B)
Safety
Laser
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 2
EN 60950
z ITU-T Rec.G.984.2 (Class B+), G983.3
z FCC 47 CFR Part 15, Class B
z FDA 21 CFR 1040.10 and 1040.11, Class I
z IEC 60825, Class I
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 3
ONT G-25E Hardware Installation Manual
2. Safety
CAUTION: Product installation should be performed only by trained service personnel.
Read and follow all warning notices and instructions marked on the product or included in its
packaging, and observe all safety instructions listed in this guide while handling any ONT.
Figure 1 ONT G-25E product label
2.1 Electrical Safety
z Always use caution when handling live electrical connections.
z Do not install electrical equipment in wet or damp conditions.
z Ensure that the power source for the system is adequately rated to assure safe operation
and provides current overload protection.
zDo not allow anything to rest on the power cable, and do not place this product where
people will stand or walk on the power cable.
zTo avoid electric shock of user which caused by over-voltage from PSTN, DO NOT connect
the POTS port on this unit directly to external PSTN line.
zThis unit can only be used with the certified adaptor model included inside the package,
which complies with the requirement of limited power source.
DANGER: Do not open the enclosure without CIG’s permission and technical support, which
is dangerous and voids the warranty.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 4
ONT G-25E Hardware Installation Manual
2.2 Laser Safety
CAUTION: Use of controls or adjustments, or performance of procedures other than those
specified herein may result in hazardous laser radiation exposure.
Invisible laser radiation may be emitted from the ends of un-terminated fiber cables or
connectors. Never look directly into an un-terminated cable or connector.
This ONT uses a class I laser device.
DANGER: Personnel handling fiber optic cables must be trained for laser safety.
CAUTION: Do not bend the fiber optic cable to a diameter smaller than 7.5 cm/3 inches.
Doing so may damage the fiber or prevent the signal from passing through properly.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 5
ONT G-25E Hardware Installation Manual
3. Installation
3.1 Site Preparation
3.1.1 Environmental Requirements
The ONT will operate in temperatures ranging from 0° C to 40° C, relatively humidity ranging
from 0° C to 85° C.
3.1.2 Power Requirements
The ONT will be shipped with a universal power adaptor. However, before installation, check if
the AC power input matches the specification printed on the power adaptor (input voltage,
current, etc.)
CAUTION: Please use the power adaptor within the package only, or the replacement unit
that provided by CIG. Other power adaptor may cause damage to the ONT and other
disasters.
3.2 Connecting to Network
1. Remove the Laser Lock Door (Figure 2).
Figure 2 Remove the Laser Lock Door
2. Remove the dust covers from the SC/APC optical connectors. Clean the connector if
necessary.
3. Plug in the fiber connector to connect the ONT to the network (
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 6
Figure 3).
ONT G-25E Hardware Installation Manual
Figure 3 Plug in the fiber connector
4. Attach the Laser Lock Door to the ONT (Figure 4).
Figure 4 Attach the Laser Lock Door
5. Finally it looks like figure below (Figure 5).
Figure 5 Connect to network: final view
3.3 Connecting Power
1. Plug the circle two pin 12V DC power connector of power converter to ONT power port
2. Plug the input of power converter into a live AC outlet
3. Verify that the power (POWER) LED on the ONT is lit green indicating that local power is on
and voltage is good.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 7
ONT G-25E Hardware Installation Manual
3.4 Connecting Telephone (POTS) Service
1. Locate the premises’ telephone wire pair.
2. If the wire pair is not terminated, follow local practices to attach an RJ-11 connector.
3. Plug the wire pair with RJ-11 connector into one of the ONT RJ-11 phone jacks.
4. Repeat step 2-3 as needed to connect additional phone lines.
Pin Signal Pin Signal
1 Unused 3 Tip
2 Ring 4 Unused
Table 6 POTS RJ-11 connector wiring pattern
DANGER: Please make sure the wire pair connected is from/to the telephone. Using the
wire pair from/to the PSTN network falsely may cause damage to user and the device.
3.5 Connecting Ethernet Service
1. Locate the premises’ Ethernet LAN cable.
2. If the cable is not terminated, follow local practices to attach an RJ-45 connector. Table
shows Ethernet RJ-45 connector wiring information.
3. Plug the Ethernet cable into the ONT RJ-45 Ethernet port.
4. Repeat step 2-3 as needed to connect additional Ethernet cables.
Pin Color Signal Pin Color Signal
1 Orange/White Tx + 5 Blue/White Unused
2 Orange Tx — 6 Green Rx —
3 Green/White Rx + 7 Brown/White Unused
4 Blue Unused 8 Brown Unused
Table 7 Ethernet RJ-45 connector wiring pattern
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 8
ONT G-25E Hardware Installation Manual
3.6 Verify the Installation
Check LED states to verify ONT status (Section 3.6.1).
Services are not available until the ONT is ranged and provisioned in the PON network. If
services must be verified at the time of installation, refer to Section
instructions.
3.6.2 for additional
3.6.1 Verif ying ONT Stat us
Once the ONT installation is complete, follow the procedure below for verifying ONT status.
Figures below show the typical status LED display after the ONT boot sequence is complete.
Figure 6 ONT has not yet been provisioned
Figure 7 ONT has already been provisioned
• Verify that the POWER LED lights green indicating that local power level is good.
• Verify that the OPTICAL LED lights green indicating that the ONT is operating normally.
- If the ONT has already been provisioned in the network, the OPTICAL LED lights green after
the ONT boot sequence and PON ranging process is complete (approximately 1 minute after
power up). During that ranging process, the OPTICAL LED flashes continually.
The ONT is placed into service remotely through the OLT. Services to the ONT are likewise
provisioned and turned up remotely through the PON network.
• If the OPTICAL LED lights green, indicating that the ONT is communicating with the PON
network, no further activation is necessary and you can proceed to Section
Services.
3.6.2: Verifying
• If the OPTICAL LED does not light green, contact the NOC
activate the line. You may be required to provide or confirm the following information about the
ONT: vendor, model number, serial number. Once the ONT has been activated in the network,
and the OPTICAL LED lights green, you can proceed to Section
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 9
(Network Operation Center) to
3.6.2: Verifying Services.
ONT G-25E Hardware Installation Manual
3.6.2 Verifying Services
Follow local practices to connect to each active service port in the ONT to confirm service
activation.
1. Connect to each active phone jack to verify telephone numbers and services. Verify that the
POTS LED lights green when a line is off hook.
2. If Ethernet service is included in this installation, confirm that data is being received and
transmitted normally. The LAN LED flashes during data transmission.
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 10
ONT G-25E Hardware Installation Manual
4. Troubleshooting
4.1 ONT Status LEDs
The ONT status LEDs located on the enclosure (Figure 8) assist with installation and
maintenance procedures. These LEDs are described in detail in
Table 8.
Figure 8 ONT Status LEDs location
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 11
ONT G-25E Hardware Installation Manual
LED Name Color Indicates
Green/Solid ONT operating from AC power.
POWER
OPTICAL
LAN
UPGRADE
Green/Quick Flash System Booting.
ONT operating from battery power
Green/Flash
Red/Solid Optical interface abnor mal (L OS/LO F) .
Green/Solid ONT working normally.
Green/Flash ONT in ranging and synchronization process.
Green/Solid
Green/Flash
OFF
Green/Flash In upgrading.
Red/Solid Upgrade failure.
OFF ONT working normally.
only for ONT equipped with UPS power
interface).
At least one of the Ethernet links at the ONT is
up.
At least one of the Ethernet links at the ONT is
up and there is activity of receiving and
transmitting data.
No Ethernet link is up at the ONT or the ONT
is not ready for running Ethernet service.
(applicable
Green/Solid No alarm with local access enabled
Red/Flash Software out of order.
ALARM
Red/Solid Hardware out of order.
OFF No alarm.
At least one POTS interfaces is in off-hook
condition.
At least one POTS interfaces is in off-hook
condition for at least one hour.
All POTS interfaces are in the on-hook
condition
POTS service.
or the ONT is not ready for running
POTS
Green/Solid
Green/Flash
OFF
Table 8 ONT Status LEDs description
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 12
ONT G-25E Hardware Installation Manual
4.2 Troubleshooting Procedures
Problem Possible Solutions
Make sure the power cable connector is properly
seated in the ONT power input.
Verify that the power adapter is plugged into a live
AC outlet.
The POWER LED is off
The ALARM LED is red
flashed or in red solid
The OPTICAL LED is in red
solid
The OPTICAL LED is
always green flashed If provisioning is correct, have the NOC
The UPGRADE LED is in
red solid
Check the power cable for shorts or breaks.
Disconnect the power input co nnector at the ONT
and use a voltmeter to verify that the proper
voltage level is present on the 12 V pin (power and
power return) from the power adapter.
Power cycle the ONT by unplugging it from the
power adapter, then plugging it back in. If the
ONT fails the self test a second time, replace
the unit.
Check the optical path.
Reset the ONT by reset button. If the ONT fails
again, replace the unit.
This is normal at boot-up and may take up to 1
minute to turn green. If this state persists, contact
the NOC (Network Operation Center) to verify that
the ONT serial number, password, and vendor ID
match those provisioned in the network database.
determine whether there are alarms on the PON
feeding the ONT. If no alarms exist, use an
optical power meter to troubleshoot the fiber
network.
Contact NOC.
The POTS LED is off when
telephone off-hook
The Data LED is off
Check the telephone connection, or voice service
is disabled. Contact NOC for verification.
Check the Ethernet connection, or data service is
disabled. Contact NOC for verification.
Table 9 Troubleshoot procedures
313-12201-02 Rev. B: August 2007 Cambridge Industries Group Co. Ltd 13
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.