Calsense ET2000 Setup Instructions

Page 1
since 1986
® MOISTURE SENSOR SETUP
MOISTURE SENSOR
ET2000 (500 SERIES) MOISTURE SENSOR SETUP
8
4
3
2
1
10 9
1 STOP – The STOP key will stop any currently
running Scheduled watering Cycle, Manual Cycle, Test Cycle, Manual Special Sequence.
2 MANUAL – The MANUAL key will perform
Manual Water, Test, Master Valve Override and Manual Program 1 & 2, Walk-thru, and Use Hold-over.
3 NO WATER – The NO WATER key will turn the
controller Off and set No Water Days.
4 ? – The ? key is used to access the controller
Help screens.
5 ENGLISH / ESPANOL – The ENGLISH /
ESPANOL key allows you to toggle the displayed text between English and Spanish.
6 BACK – The BACK key will go back to the
previous screen.
8
5
6
7
7 MAIN MENU – The MAIN MENU key is used to
access the different program features of the controller.
8 MENU KEYS – MENU keys select the different
features of commands in the different screens and are adjacent to the left and right side of the controller’s display screen. The text in the screen will point towards the MENU key that needs to be pressed.
9 LEFT / RIGHT ARROW KEYS – The LEFT /
RIGHT ARROW keys move the highlighted cursor around the different screens when setting up or editing the controller’s features and options.
10 PLUS / MINUS KEYS – The PLUS / MINUS
keys increase or decrease values or answer Yes or No questions in the different screens.
making
Page 2
since 1986
Setup Status
Flow Radio Remote
Weather Reports
CALSENSE WATER MANAGEMENT SYSTEM
Programs & Stations Lights
Rain Switch
Wind Gage Moisture
Rain Bucket Budget
WEATHER SETUP
ET Gage ET
Moisture Sensing in Use ? NO
MOISTURE SENSING SETUP
Moisture Sensing in Use ? YES
PROG A . . . . . . . . . . . . . . . . . . . . . . . . . . YES
MOISTURE SENSING SETUP
USE BY PROGRAM
PROG C . . . . . . . . . . . . . . . . . . . . . . . . . . YES
PROG B . . . . . . . . . . . . . . . . . . . . . . . . . . YES
PROG D . . . . . . . . . . . . . . . . . . . . . . . . . . YES
Sensor Assignment
PROG E . . . . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 1 . . . . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 2 . . . . . . . . . . . . . . . . . . . . . . . . . . YES
Moisture Sensing in Use ? YES
PROG A . . . . . . . . . . . . . . . . . . . . . . . . . . YES
MOISTURE SENSING SETUP
USE BY PROGRAM
PROG C . . . . . . . . . . . . . . . . . . . . . . . . . . YES
PROG B . . . . . . . . . . . . . . . . . . . . . . . . . . YES
PROG D . . . . . . . . . . . . . . . . . . . . . . . . . . YES
Sensor Assignment
PROG E . . . . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 1 . . . . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 2 . . . . . . . . . . . . . . . . . . . . . . . . . . YES
MOISTURE SENSOR SETUP ®
MOISTURE SENSOR
1. Press the MAIN MENU key.
2. Press the WEATHER menu key
(Figure 1).
Figure 1
The WEATHER SETUP screen will appear (Figure 2).
The default setting is NO. If you are currently using Moisture sensors on this controller then change the setting to YES.
4. Press the PLUS or MINUS keys to change the settings.
The MOISTURE SENSOR SETUP screen will change to reveal the Use by Program settings (Figure 4).
Figure 4
5. Press the Blue ARROW keys to move the cursor to the next entry.
Figure 2
3. Press the MOISTURE Menu key. This will bring up the MOISTURE SENSING SETUP screen (Figure 3).
Figure 3
Figure 5
To change the Use by Program,
6. Press the PLUS or MINUS keys. (Figure 5).
7. Press the Blue ARROW keys to move the cursor to the next entry.
This will allow you to set up the programs that you want to use Moisture Sensors on.
making
Page 3
since 1986
Sensor 01 02 03 04 05 06 07 08 09 10
Station 21 22 23 24 25 26 27 28 29 30
Sensor 21 22 23 24 25 26 27 28 29 30
Station 31 32 33 34 35 36 37 38 39 40
Sensor 11 12 13 14 15 16 17 18 19 20
Station 11 12 13 14 15 16 17 18 19 20
Sensor 31 32 33 34 35 36 37 38 39 40
MOISTURE SENSOR ASSIGNMENT
Station 01 02 03 04 05 06 07 08 09 10
Setup Status
Flow Radio Remote
Weather Reports
CALSENSE WATER MANAGEMENT SYSTEM
Programs & Stations Lights
PROGRAMS & STATIONS
Start Times & Water Days
Stations
Station-to-Station Copy
Total Mins : 5.0
Test
Moist Set : 99
Moist Read : - -
MASTER
Soak-In Time : 5 No Water Days 0
Max Days : 00
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
® MOISTURE SENSOR SETUP
8. Press the SENSOR ASSIGNMENT Menu key. This will take you to the MOISTURE SENSOR ASSIGNMENT SCREEN (Figure 6).
Figure 6
Next you will have to enter the settings for each Moisture sensor assigned to a station.
A representative station for each different climatic and plant material zone on the controller is given a sensor and is known as a Master station. Slave stations are stations without sensors and are assigned to a master station which share similar water requirements. The choice of groups of stations controlled by the same sensor is done at the controller within the MOISTURE SENSOR ASSIGNMENT screen.
9. Press the PLUS or MINUS keys to change the entry.
Figure 7
12. Press the PROGRAMS & STATIONS Menu key (Figure 7).
This will take you to the PROGRAMS & STATIONS screen. (Figure 8).
Figure 8
13. Press the STATIONS Menu key. (Figure 8).
This will take you to the STATION PROGRAMMING screen (Figure 9).
10. Press the Blue ARROW keys to move the cursor to the next entry.
Once all of the Moisture Sensors have been set up properly,
11. Press the MAIN MENU key to return to the MAIN MENU screen (Figure 7).
Figure 9
14. Press the Blue ARROW keys to move the cursor to the MAX DAYS entry.
making
Page 4
since 1986
Total Mins : 5.0
Max Days : 00
Moist Set : 99
Moist Read : - -
MASTER
Soak-In Time : 5 No Water Days 0
Test
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
Total Mins : 5.0
Max Days : 00
Moist Set : 99
Moist Read : - -
MASTER
Soak-In Time : 5 No Water Days 0
Test
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
Total Mins : 5.0
Max Days : 00
Moist Set : 99
Moist Read : - -
MASTER
Soak-In Time : 5 No Water Days 0
Test
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
MOISTURE SENSOR SETUP ®
MAX DAYS: This entry is used to automatically bypass the moisture sensors of individual stations, separate program stations or all stations, for one to thirty-one days. Stations will receive their maximum programmed water time. The controller will display the number of days remaining in override and can be cleared at any time. After the programmed Maximum Water has elapsed, the system will automatically return to moisture sensing operation (Figure 10).
Figure 10
15. Press the PLUS or MINUS keys to change the entry.
Figure 11
MOIST READ: This entry is non-changeable. The
Calsense Moisture sensor is not an On / Off switch. It will never irrigate more than what is programmed on the controller. As a moisture sensor reading goes above the determined moisture set point, the controller irrigates less of the programmed time until it may not water at all.As the controller irrigates less, the moisture level reading drops below the moisture set point. Once this occurs, the controller automatically begins to irrigate more of the programmed time to where it may water the full programmed amount (Figure 12).
16. Press the Blue ARROW keys to move the cursor to the MOIST SET entry.
MOIST SET: The Calsense Moisture Sensor has it’s own numerical system of moisture readings. Typically it reads between the range of 45 (dry) to 85 (wet). By keeping moisture set points at 99, the sensors are never allowed to read above the set point value, and the controller waters the full programmed time. This occurs for the Master station as well as all slave stations assigned to the Master Station. After a few weeks, the slave areas should be checked and readjusted if necessary. If the slave area is to dry, adjust it’s maximum time to 25% more. If the area is to wet, decrease it by the same percentage. In both cases, the area should be rechecked after another few weeks, with adjustments made until the proper irrigation level is achieved (Figure 11).
Figure 12
17. Press the TEST Menu key to test the station that you are currently on.
18. If you want to test a different station press the STATION UP or STATION DOWN keys to the right of the display screen (Figure 13).
This will only test the station selected, but will not get a reading from the moisture sensor.
making
Page 5
since 1986
Total Mins : 5.0
Max Days : 00
Moist Set : 99
Moist Read : - -
MASTER
Soak-In Time : 5 No Water Days 0
Test
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
MANUAL MENU
Manual Watering Manual Program 1
Test Manual Program 2
MV Override Walk-Thru
Use Hold-Over
Test Station 1 for 2.0 minutes
Test Station 1 for Moisture Sensor
( MASTER )
VALVE TESTING
Learn the Expected at Station 1
Test Station 1 for 2.0 minutes
Test Station 1 for Moisture Sensor
( MASTER )
VALVE TESTING
Learn the Expected at Station 1
Total Mins : 5.0
Max Days : 00
Moist Set : 99
Moist Read : 45
Soak-In Time : 5 No Water Days 0
Test
STATION PROGRAMMING
Station 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROG A
Mins per Cycle : 2.5
MASTER
® MOISTURE SENSOR SETUP
Figure 13
If you want to retrieve a current reading from the moisture sensor,
19. Press the MANUAL Menu key. This will take you to the MANUAL IRRIGATION screen (Figure 14).
Figure 14
Figure 16
22. Press the PLUS or MINUS key to change the station entry.
Note: Only Master stations can be tested for Moisture sensors, slave stations will not be able to test.
23. Press the TEST STATION # FOR MOISTURE SENSOR Menu key to activate test. The screen will show “READING SENSOR ON # please wait (Less than 15 seconds)” for which ever station you selected. After a brief test the STATION PROGRAMMING screen will appear with the new Moisture sensor reading displayed (Figure 17).
20. Press the TEST Menu key to access the VALVE TESTING screen (Figure 15).
Figure 15
21. Press the Blue ARROW keys to move the cursor to the TEST
STATION # FOR MOISTURE SENSOR Entry (Figure 16).
Figure 17
24. Press the MAIN MENU key to return to the MAIN MENU screen (Figure 1).
making
Page 6
since 1986
MOISTURE SENSOR SETUP ®
2075 Corte del Nogal, Suite P, Carlsbad CA 92011
1-(800)-572-8608 FAX: 1-(760)-438-2619
Stock Number: PG1-MS-D3 Rev. 02/06
www.calsense.com
making
®
Loading...