running Scheduled watering Cycle, Manual
Cycle, Test Cycle, Manual Special Sequence.
2 MANUAL – The MANUAL key will perform
Manual Water, Test, Master Valve Override and
Manual Program 1 & 2, Walk-thru,
and Use Hold-over.
3 NO WATER – The NO WATER key will turn the
controller Off and set No Water Days.
4 ? – The ? key is used to access the controller
Help screens.
5 ENGLISH / ESPANOL – The ENGLISH /
ESPANOL key allows you to toggle the displayed
text between English and Spanish.
6 BACK – The BACK key will go back to the
previous screen.
8
5
6
7
7 MAIN MENU – The MAIN MENU key is used to
access the different program features of the
controller.
8 MENU KEYS – MENU keys select the different
features of commands in the different screens
and are adjacent to the left and right side of the
controller’s display screen. The text in the screen
will point towards the MENU key that needs to
be pressed.
9 LEFT / RIGHT ARROW KEYS – The LEFT /
RIGHT ARROW keys move the highlighted
cursor around the different screens when setting
up or editing the controller’s features and
options.
10 PLUS / MINUS KEYS – The PLUS / MINUS
keys increase or decrease values or answer Yes
or No questions in the different screens.
8. Press the SENSOR ASSIGNMENT Menu key. This
will take you to the MOISTURE
SENSOR ASSIGNMENT
SCREEN (Figure 6).
Figure 6
Next you will have to enter the settings for each
Moisture sensor assigned to a station.
A representative station for each different climatic
and plant material zone on the controller is given a
sensor and is known as a Master station. Slave
stations are stations without sensors and are
assigned to a master station which share similar
water requirements. The choice of groups of stations
controlled by the same sensor is done at the
controller within the MOISTURE SENSOR
ASSIGNMENT screen.
9. Press the PLUS or MINUS keys to
change the entry.
Figure 7
12. Press the PROGRAMS &
STATIONS Menu key (Figure 7).
This will take you to the PROGRAMS & STATIONS
screen. (Figure 8).
Figure 8
13. Press the STATIONS Menu key.
(Figure 8).
This will take you to the STATION PROGRAMMING
screen (Figure 9).
10. Press the Blue ARROW keys to
move the cursor to the next entry.
Once all of the Moisture Sensors have been set up
properly,
11. Press the MAIN MENU
key to return to the MAIN MENU
screen (Figure 7).
Figure 9
14. Press the Blue ARROW keys to
move the cursor to the MAX DAYS
entry.
MAX DAYS: This entry is used to automatically
bypass the moisture sensors of individual stations,
separate program stations or all stations, for one to
thirty-one days. Stations will receive their maximum
programmed water time. The controller will display
the number of days remaining in override and can
be cleared at any time. After the programmed
Maximum Water has elapsed, the system will
automatically return to moisture sensing operation
(Figure 10).
Figure 10
15. Press the PLUS or MINUS keys to
change the entry.
Figure 11
MOIST READ: This entry is non-changeable. The
Calsense Moisture sensor is not an On / Off switch.
It will never irrigate more than what is programmed
on the controller. As a moisture sensor reading goes
above the determined moisture set point, the
controller irrigates less of the programmed time until
it may not water at all.As the controller irrigates less,
the moisture level reading drops below the moisture
set point. Once this occurs, the controller
automatically begins to irrigate more of the
programmed time to where it may water the full
programmed amount (Figure 12).
16. Press the Blue ARROW keys to
move the cursor to the MOIST SET
entry.
MOIST SET: The Calsense Moisture Sensor has it’s
own numerical system of moisture readings.
Typically it reads between the range of 45 (dry) to 85
(wet). By keeping moisture set points at 99, the
sensors are never allowed to read above the set
point value, and the controller waters the full
programmed time. This occurs for the Master station
as well as all slave stations assigned to the Master
Station. After a few weeks, the slave areas should
be checked and readjusted if necessary. If the slave
area is to dry, adjust it’s maximum time to 25%
more. If the area is to wet, decrease it by the same
percentage. In both cases, the area should be
rechecked after another few weeks, with
adjustments made until the proper irrigation level is
achieved (Figure 11).
Figure 12
17. Press the TEST Menu key to test
the station that you are currently
on.
18. If you want to test a different station
press the STATION UP or STATION DOWN keys to the right of the
display screen (Figure 13).
This will only test the station selected, but will not
get a reading from the moisture sensor.
If you want to retrieve a current reading from the
moisture sensor,
19. Press the MANUAL Menu key.
This will take you to the MANUAL
IRRIGATION screen (Figure 14).
Figure 14
Figure 16
22. Press the PLUS or MINUS key to
change the station entry.
Note: Only Master stations can be tested for
Moisture sensors, slave stations will not be able to
test.
23. Press the TEST STATION # FOR MOISTURE SENSOR Menu key to
activate test. The screen will show
“READING SENSOR ON # please
wait (Less than 15 seconds)” for
which ever station you selected.
After a brief test the STATION
PROGRAMMING screen will
appear with the new Moisture
sensor reading displayed
(Figure 17).
20. Press the TEST Menu key to
access the VALVE TESTING
screen (Figure 15).
Figure 15
21. Press the Blue ARROW keys
to move the cursor to the TEST
STATION # FOR MOISTURE
SENSOR Entry (Figure 16).
Figure 17
24. Press the MAIN MENU key to
return to the MAIN MENU screen
(Figure 1).
making
Page 6
since 1986
water work
MOISTURE SENSOR SETUP ®
2075 Corte del Nogal, Suite P, Carlsbad CA 92011
1-(800)-572-8608 FAX: 1-(760)-438-2619
Stock Number: PG1-MS-D3 Rev. 02/06