Calomax Eclipse Series Installation, Operation And Servicing Instructions

INSTALLATION, OPERATION AND SERVICING INSTRUCTIONS
FOR THE ECLIPSE RANGE OF WATER BOILERS
Please read these instructions carefully before operating your boiler for the first time
Issue 5
DCR :939
Calomax Limited
Lupton Avenue, Leeds LS9 7DD
Tel. 0113 249 6681 Fax. 0113 235 0358
e-mail: service@calomax.co.uk www.calomax.co.uk
Page 2
CONTENTS
INTRODUCTION 3
CHECK LIST 3
APPROVALS 3
CONSTRUCTION 4
INSTALLATION 4
LOCATION 4
COLD WATER INLET 5
ACCESS INSTRUCTIONS 6
VENT / OVERFLOW 7
ELECTRICAL CONNECTIONS 8
USER INSTRUCTIONS 8
SCALE 9
GENERAL OPERATION 9
CLEANING 9
TROUBLE SHOOTING 10
ACCESSORIES 11
SPARE PARTS 12/13
EXPLODED DIAGRAM 14/15/16/17
SERVICE INSTRUCTIONS 18/19
GENERAL FUNCTION 20
WIRING DIAGRAM 21
DIMENSIONS AND WEIGHTS 22
WARRANTY 23
PRODUCT SPECIFICATION 24
PAGE
Page 3
INTRODUCTION
Thank you for purchasing a boiler from the Calomax Eclipse range. All our products are designed to give years of simple, reliable operation. To ensure this, it is important that the installation and subsequent servicing and maintenance is carried out by a suitably qualified engineer in accordance with these instructions. For assistance in finding a suitable engineer in your area, visit our website www.calomax.co.uk, contact our service department on 0113 249 6681 or e-mail: service@calomax.co.uk
CHECK LIST counter top models
Before commencing installation, check that the following parts have been supplied with the boiler:
1. Wall mounting bracket
This product conforms to the CE marking directive 93/68/EEC through compliance with the following standards:
Electromagnetic Compatibility Directive Low Voltage Directive 73/23/EEC in accordance with: BS EN 60335-2-75:2004. Compliance with these standards has been confirmed through testing by an independent NAMAS approved body
APPROVALS
CHECK LIST wall mounted models
Before commencing installation, check that the following parts have been supplied with the boiler:
1. WRAS approved flexible water inlet hose suitable for potable water.
2. Drip tray kit
The tap handle and drip tray (part ref: MDTBK where supplied) have been treated with Steritouch additive and independently tested to prove the effectiveness of the surface hygiene.
Page 4
LOCATION
INSTALLATION AND MAINTENANCE
All metallic components of the machine, in direct contact with drinking water are manufactured from high quality 304 grade stainless steel, or non ferrous materials, providing maximum resistance to corrosion.
CONSTRUCTION
To comply with recommendations from the Health and Safety Executive it is important that due consideration be given to safe operation of the controls of the boiler. The boiler should therefore be mounted in such a manner that the operator can stand directly facing the machine with the controls at a recommended height from the floor to the draw-off tap handle of 1200mm +/- 100mm. Consideration should also be
The boiler must be installed in a location where access is restricted to operators that are suitably trained, or where untrained operators of the machine can be supervised by trained personnel.
Calomax products have been tested and found to comply with the requirements of the Water Supply (Water Fittings) Regulations 1999 for England and Wales Water Bylaws 2000, Scotland and the Water Regulations Ireland.
given to the servicing requirements of the machine. The maximum and minimum ambient operating conditions must be between 5 °C and 35 °C. The appliance is not suitable for installation where a water jet could be used. Install the boiler on a surface or wall suitable for the working weight of the boiler. Allow clearance for ventilation and for the easy removal of the outer casing lid and front panel. Calomax ltd recommend a minimum clearance of 50mm on all sides of the boiler. A suitably qualified engineer must install this unit. Plumbing and electrical installation work may be involved.
p PP
Page 5
COLD WATER INLET
TO COMPLY WITH U.K. WATER SUPPLY
REGULATIONS A SINGLE CHECK VALVE MUST BE FITTED. BEFORE CONNECTING, THE SUPPLY PIPE
MUST BE THOROUGHLY FLUSHED OUT TO ENSURE THAT FOREIGN MATTER DOES NOT BLOCK OR ENTER THE SOLENOID VALVE The boiler must be connected to a potable water supply using the food grade hose where provided, or rigid 15mm pipe in a manner which complies with UK water regulations via an appropriate isolating valve. Always use the new hose supplied (counter-top models only). Do not reuse old hoses. The supply must provide a constant pressure of between 20 KPa and 1000 KPa (0.2 to 10 Bar). If the water supply contains excessive solids in suspension it is recommended that a fine mesh “in line” water filter is fitted in the pipe work. Failures due to scale and sediment are not covered by the warranty.
3 point fixing wall bracket .for wall mounted range
Hang the boiler on the wall bracket and secure into place with 4th fixing. The electrical cable should be routed as shown. The use of 6mm Rawl-Bolts is recommended to secure the bracket to a wall of appropriate construction to support the working weight of the boiler.
Cold water inlet
Vent & overflow
4th fixing
Page 6
ACCESS INSTRUCTIONS
Access to the internals of the machine is gained by the removal of the front panel. Prise off the outercasing lid from its mounting clips. remove the top two panel mounting screws, and the third bottom mounting screw (where fitted). Remove the cover. The 3C5C model does not have the third screw, it is fitted with two more clips at the bottom of the panel which can be prised off.
Page 7
VENT & OVERFLOW
The vent / overflow pipe must be extended and laid with a
continuous
fall,
discharging to a safe and visible point. The pipe should not be directly connected to a closed waste, as taste problems may occur and should never be allowed to become blocked or restricted.15mm copper or ‘Speedfit’ pipe should be used. The drip tray kit provided with the counter top models allow the option of plumbing the overflow pipe to discharge into the drip tray and then plumbing the drip tray to a safe and visible point of discharge. If the machine is operated without the overfill pipe being extended as advised, any subsequent damage incurred will be the responsibility of the installer.
If the boiler is required to drip or overflow into the drip tray, the configuration of pipework may be altered as follows. Remove the machine front panel and unclip the pipework elbow. Carefully pull the elbow in the direction of the arrow, out of the silicone connecting tube on the end of the main water pipe. The silicone connecting tube will now direct water into the drip tray.
Page 8
This equipment is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance
In the event of the power supply lead to the boiler becoming damaged, the appliance must be removed from service. A replacement genuine part is available from Calomax Ltd, and must be fitted by a suitably qualified engineer
Commissioning
Turn on the water supply and then switch on the electrical supply. When the power switch is pressed on the front fascia the Wait light will illuminate and the unit will fill with water (1.3 L/Min). When water reaches the low water level sensor, the element will be energised and the solenoid will continue to fill the boiler to the normal operating water level. When the water has reached the normal operating temperature, the Wait light will extinguish and the ready light will illuminate. At this time the full light will be illuminated indicating that the machine has reached full capacity of boiling water.
Subsequent Use
After the boiler has finished the commissioning cycle, and water is drawn from the tap, water will be replenished in short cycles (Small amount of water and then heat). The solenoid and element will never be on at the same time unless the boiler is switched off and on again (Re-setting commission mode). In normal use the boiler will always be
USER INSTRUCTIONS
During normal operation some external parts will become very hot, particularly the tap body. Care must be taken to avoid injury, a burn or scald.
ELECTRICAL CONNECTIONS
The boiler should be connected to a 240v ac 13A electrical supply, capable of carrying a load of 3kW. The installation of a residual current device (RCD) having a rated residual operating current not exceeding 30 mA is advisable.