California Faucets TO-THCN-XX User Manual

TO-THN-XX & TO-THCN-XX
¾” Thermostatic Valve Trim
StyleTherm
Installation Instructions
TH75-R
(ROUGH)
TO-THN-XX_ii_120227.doc Pg 1
CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED BY
A LICENSED PROFESSIONAL
TEMPERATURE SETTING
Remove SCREW (2), WASHER (3), MUDGUARD
(4) and SLEEVE (5) from installed VALVE (1)
Push plastic TEMPERATURE LIMIT STOP (6) onto
THERMOSTATIC CARTRIDGE (7) as shown
Temporarily place BONNET (8) onto
THERMOSTATIC CARTRIDGE STEM (7a)
With both hot and cold water supplies on, open
stop/volume control valve to one output device
Use temperature measuring device to confirm
temperature is 100°F when BONNET (8) button is positioned straight up at 12 o’clock
When button on BONNET (8) is depressed and
rotated full left (CCW), the maximum temperature discharged from valve will be 115°F (Note: Follow all applicable local plumbing codes when setting maximum discharge water temperature)
Carefully remove BONNET (8) and place aside
until trim is installed
Note: If temperature is not 100°F with BONNET (8), button at 12 o’clock, the CARTRIDGE STEM (7a) must be rotated to change temperature setting (clockwise (CW) for cooler & counter-clockwise (CCW) for warmer)
WARNING: Forcibly rotating thermostatic cartridge stem prior to installing handle trim, will damage cartridge and void warranty.
INSTALL TRIM
Position FACEPLATE (9) onto CARTRIDGE NUT
(10) as shown
Install SLEEVE (11) onto CARTRIDGE NUT (10)
and tighten to secure FACEPLATE (9) against shower wall
Place BONNET (8) onto THERMOSTATIC
CARTRIDGE STEM (7a)
Secure BONNET (8) with SCREW (12)
Place HANDLE (13) onto BONNET (8) and
tighten handle SETSCREW (14)
100°F
Rotate CW for Cooler (shown)
Rotate CCW for Warmer
Note: Depending on handle style, it may be necessary
to cut BONNET STEM (8a) and SCREW (12) to allow HANDLE (13) to fully seat against BONNET (8)
TO-THN-XX_ii_120227.doc Pg 2