Tel: 714-891-7797
Fax: 714-891-2478
Toll Free: 800-822-8855
www.calfaucets.com
WALL DIVERTER VALVE
INSTALLATION
INSTRUCTIONS
WDV-R & WDV-NS-R
IMPORTANT
R
All
products are engineered to provide quality performance provided
they are installed and operated properly. To fully enjoy the comfort, safety, and reliability of your
new Wall Diverter Valve, please follow the instructions below.
California Faucets reserves the right to make modification and specification changes at any time.
Please visit www.calfaucets.com for most current technical data.
Fig. 2A
Oulet:
Outlet:
Port #3
Intlet Port
Valve
Body
Port #1
Detent Disk
Cartridge
3-Way Stop Ring
Outlet:
Port #2
Fig. 1B
Nut
Broach
Cartridge
Outlet
Supplied on unit
3-Way Installation
Fig. 2B
L
Included if needed for
2-Way Installation Left
Fig. 2C
All Thread
Fig. 1A
Inlet/Outlets: 1/2" NPT Male (or) 1/2" Copper Sweat.
Included if needed for
R
2-Way Installation Right
Wall Diverter Installation
-Diverter valve has the capability for 3 port / 5 mode or 2 port / 3 mode operation.
-Inlet is located at the back and bottom of the valve with an arrow for inlet identification.
The outlets are also marked with numbers 1, 2, and 3 respectively.
Connection types: NPT Thread (or) copper sweat "solder"
-For solder connections either directly to the valve, or within 6" of the valve, the CARTRIDGE MUST BE REMOVED
from the body. When soldering do not apply excessive heat directly to the body. Failure to follow these directions
can cause damage to the body, detent disk and or cartridge, and may nullify the warranty.
-Remove all thread, broach, body nut, cartridge and detent disk from valve body.
-Valve comes as standard with default 3 port / 5 mode and can be configured to 2 port / 3 mode.
-Define how many ports and modes are needed for your application and install the valve according
to the inlet / outlets to meet those requirements. (See Fig. 1A & 4)
-Connect the mixed water supply to the diverter valve inlet.
-Connect the outlets to the desired number of applications. (for 3 way) use all 3 outlet ports, and for (2 way) use outlets 1
and 2 to the right, (or) use outlets 1 and 3 to the left. Cap off any unused outlets to avoid potential water leakage
behind the wall. (See Fig. 1 & 4)
-Install adequate bracing support in the wall, and secure the diverter valve to the bracing.
-Remove the 3 way stop ring from the cartridge (See Fig. 1)
-Apply some silicone O-Ring grease to the detent disk and attach it to the bottom of the cartridge aligning the 2 pins
horizontal to the outlet opening of the cartridge. (See Fig. 1B)
-Align the cartridge outlet with the top outlet and insert the cartridge into the body and gently push it all the way in so the detent
disk pins fit into the holes inside the body. When fully inserted the cartridge will be recessed in th top of the valve.
-Install the stop ring according to installation type you have. (2 way stop ring) for 2 way function to the left or right) or 3 way
for all outlets. (See Fig. 2A, 2B & 2C). Parts 2B & 2C are the same, but reversible for 2-Way right or left.
-Install body nut and tighten securely. Then install the broach and all thread (do not overtighten all thread onto body nut).
WDV-R_ii_130920
Pg 1
Valve Body
1
Detent Disk
2
3
Cartridge
4
2-Way Stop Ring
5
3-Way Stop Ring
Body Nut
6
7
Broach O-Ring
Broach
8
All Thread
9
1
3
IN
(O-Rings)
1 2 3 86
5
4
7
-Install trim, (base ring if applicable), escutcheon and handle and tighten set screws with allen key
provided.
NOTE:
Cap off any unused outlets to
avoid potential water leakage
Outlets:
1/2" NPT
(Marked "1, 2 & 3")
behind the wall.
5-1/4"
4-3/4"
"A" Dimension
Ø 1-1/2" Opening
1
3
IN
Finished
Wall
9/16"
All Thread
3"
1
3
2
IN
Inlet:
3"
1/2" NPT
(Marked "IN")
6-1/8"
Fig. 4
Front View
Fig. 5
Side View
NOTE: When fitting handle it
may be necessary to shorten
broach and/or all thread to
eliminate gaps between
Pressure:
handle and escutcheon.
Maximum = 125 P.S.I. - 8.6 Bar
Hot water supply temperature = Maximum 185 °F/ 85 °C
C.S.A., A.S.S.E. & I.A.P.M.O. U.S. & CA. & WDR-NS-R: CA GREEN
Stem
Broach
Fig. 5
9
Fig. 3
"A"
DIMENSION
"A" Dimension is
from finished wall
to tip of stem broach
HANDLE
SERIES No. "A"
33 2-3/8"
34 2-3/8"
35 2-3/8"
36 2-3/8"
38 2-5/8"
40 2-5/8"
42 2-5/8"
44 2-7/16"
46 2-1/2"
47 2-1/2"
48 2-5/16"
50 2-1/4"
51 2-1/2"
53 2-1/4"
55 2-5/8"
57 2"
59 2-5/8"
60 2-1/4"
62 1-7/16"
63 3"
64 2-5/8"
65 2-1/8"
66 2-1/8"
67 2-1/4"
68 2-3/8"
69 2-3/8"
70 1-3/8"
71 1"
72 1"
73 1"
WDV-R_ii_130920
TROUBLE SHOOTING
1. Leak at body nut, and or between
broach and sleeve.
2. While using one outlet, there is water
leaking from the other outlet.
The stem O-ring is damaged.To replace the o-ring,
remove trim, body nut, then the stem.
Replace cartridge. The stem O-Ring on cartridge is defective.
To replace, remove all thread, broach, body nut and cartridge.
Fit new O-Ring and apply silicone grease. Reinstall cartridge
as described in the instruction sheet.