This manual applies to the following replaces and repits:
FPT50 FRP1000
FPT80 FRP1500
FPT90 FRP2000
FPT95 FRP3000
FPT100 FRP3100
FPT125 FRP4000
FPT200 FRP4100
FPT600 FRP4200
FPT650 FRP4300
FPT800 FRP4300A
FPT900 FRP4300B
FPT950
Copyright 2006-2007 California Acrylic Industries,
Inc. All rights reserved. Duplication without written
consent is strictly prohibited.
Cal Spas™ and Cal Flame™ are registered
trademarks.
Due to continuous improvement programs, all
models, operation, and/or specications are
subject to change without prior notice.
LTR20071006, Rev. A
11/5/2006
CONTACT INFORMATION
For customer service, please contact your authorized
dealer immediately. If you need additional information
and/or assistance, please contact:
C.A.I. Customer Service Department
1462 East Ninth Street
Pomona, CA 91766.
Toll Free: 1-800-CAL-SPAS
Fax: 1-909-629-3890

Table of Contents
WARNING
If the information in this manual is not
followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
Do not store an LP cylinder not connected
for use in the vicintiy of this or any other
appliance. A re resulting in serious injury
or death may occur.
If you are installing a natural gas grill,
you are responsible for ensuring that the
natural gas line installed is safe to use.
California Acrylics Industries (C.A.I.) will
not be held responsible for an improperly
installed gas line.
Safety Instructions . . . . . . . . . . . . . . . . . . . 2
Planning For Your Firepit or Fireplace . . . 4
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Built-in Installation. . . . . . . . . . . . . . . . . . . . . . . .4
LP Gas Requirements . . . . . . . . . . . . . . . . . . . . .4
Natural Gas Requirements . . . . . . . . . . . . . . . . .5
Testing for Leaks . . . . . . . . . . . . . . . . . . . . . . . . .6
Leak Testing Procedure. . . . . . . . . . . . . . . . . . . .6
Using Your Fireplace or Firepit . . . . . . . . . 7
Safety Information . . . . . . . . . . . . . . . . . . . . . . . .7
Lighting Your Gas Firepit . . . . . . . . . . . . . . . . . .7
Lighting and Operating Your Gas Fireplace . . .7
Turning Off the Gas for Your Gas Fireplace . . .8
Lighting Your Wood Burning Fireplace . . . . . . .8
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintaining Your Firepit or Fireplace. . . . . . . . .9
After Use Care . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Covering Your Firepit. . . . . . . . . . . . . . . . . . . . . .9
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . .9
Warranty Information. . . . . . . . . . . . . . . . . . . . .10
2007 Fireplace and Firepit Owner’s Manual Page 1
LTR20071006, Rev. A

Safety Instructions
Safety Instructions
Read this before installing or operating your new Cal Flame repit or replace.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
Unless specically recommended in this manual, do not repair or replace any part of your repit or replace. Have
a qualied technician perform all of the service. Any repairs made by a non- C.A.I. approved dealer technician will
void your warranty.
Most cities and counties require permits for exterior construction and electrical circuits. In addition, some
communities have codes requiring residential barriers such as fencing and/or self-closing gates on property to
prevent unsupervised access to the property by children under the age of 5. Your dealer can provide information
on which permits may be required and how to obtain them prior to the delivery of your equipment.
Placement and Location
Cal Flame™ replaces and repits are designed
•
for outdoor use only.
Never locate this appliance in an enclosed room,
•
under a sealed overhead structure, or in any
type of enclosed area such as a garage, shed, or
breezeway. Keep clear of trees and shrubs.
Do not place this grill under or near windows or
•
vents that can be opened into your home.
Maintain sufcient distance as to not overheat any
•
overhead combustible material such as a patio
cover.
The area surrounding your replace or repit
•
should be kept clean and free from ammable
liquids and other combustible materials such
as mops, rags or brooms, as well as solvents,
cleaning uids, and gasoline.
Do not store the liquid propane (LP) cylinder in the
•
vicinity of this or any other appliance when it is not
being used.
Do not block the vents located near the base of
•
your repit or replace as gas may build up in case
of leak and cause serious damage.
Set-Up
Your are responsible for ensuring that a natural
•
gas line (if required) is installed and safe for use.
We recommend that a licensed contractor install
your replace or repit. Installation must conform to
local codes, or in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1
/ NFPA54, Natural Gas and Propane Installation
Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2), as applicable.
Your replace or repit must be plugged into a
•
permanent, grounded 110V outlet with a dedicated
15A GFCI breaker in accordance with local codes
or the National Electrical Code, ANSI / NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
Do not use an extension cord to supply power to
•
your replace or repit. Such use may result in
re, electrical shock or other personal injury. Do
not install a fuse in the neutral or ground circuit.
A fuse in the neutral or ground circuit may result
in an electrical shock hazard. Do not ground this
appliance to a gas supply pipe or hot water pipe.
Keep any electrical supply cords and the fuel
supply hose away from any heated surfaces.
To prevent re and smoke damage, remove all
•
packaging material before operating the replace
or repit.
Operation
Do not use charcoal in this repit or replace.
•
In the event that a burner goes out, turn burner
•
knobs to the full OFF position and let it air out. Do
not attempt to use the repit or replace until the
gas has had time to dissipate.
Keep all electrical supply cords away from the
•
heated areas of the replace or repit.
Never use the replace or repit in windy
•
conditions. If used in a consistently windy area a
windbreak will be required. Always adhere to the
specied clearances listed in this manual.