www.caldura.co.uk DG30/DG40/PL22/PL30/PL40/05092013
Advanced Settings (Digital Plus Models Only)
The Caldura Digital Plus range has a number of advanced features that can
be configured using the same programming method as the thermostat
setting above. Digital units can be upgraded to Digital Plus within 6 weeks of
purchase. For upgrade information, visit www.caldura.co.uk/upgrade.
To configure advanced features, follow the steps above but use step 5 to
select the desired feature for modification as indicated in the table below.
# Confirmation Description Range Notes
2 Lo, Hi, Lo Thermostat 1 - 8 Coldest is 8
3 Lo, Hi, Hi Quick Set 1 - 4 1 Fridge
2 Minibar @ 4°C
3 Minibar @ 7°C
4 Student Fridge
4 Hi, Lo, Lo Door Opened Indicator 1 - 2 1 Off, 2 On
5 Hi, Lo, Hi Door Closed Confirmation 1 - 2 1 Off, 2 On
6 Hi, Hi, Lo Automatic Power Save 1 - 10 1 Off, 2 - 10 Days
7 Hi, Hi, Hi Automatic Standby 1 - 10 1 Off, 2 - 10 Days
8 Hi, Lo, Lo, Lo Manual Standby 1 - 2 1 Off, 2 On
9 Hi, Lo, Lo, Hi Open Door Alert 1 - 2 1 Off, 2 On, 3
Progressive
10 Hi, Lo, Hi, Lo Over Temperature Alert 1 - 2 1 Off, 2 On
Quick Set
Enables all features to be set in one go for a specific operating mode. See
table below for modes/features.
Fridge
Minibar @
4°C
Minibar @
7°C
Student
Fridge
Can Store Perishables
Yes Yes No Yes*
Thermostat Level
6 6 4 6
Door Opened Indicator
● ●
Door Closed
Confirmation
● ●
Automatic Power Save
3 Days
Automatic Standby
10 Days
Manual Standby
● ● ●
Open Door Alert
Tone Progressive Progressive Progressive
Over Temperature Alert
● ●
* Student Fridge Mode - Users should be informed that the fridge will