CalAmp 3640HEB User Manual

9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
Contents
1 Introduction
1.1 About This Manual
1.2 About The Reader
1.3 About CalAmp
2 System Overview
2.1 Overview
2.2 Component Descriptions
2.2.1 Backend Software
2.2.2 LMU Manager
2.2.3 LM Direct Server
2.2.4 Wireless Data Network
2.2.5 LMU-3640™
2.2.6 Host Device – Laptop/PDA or MDT
2.3 Wireless Data Primer
2.3.1 SMS (Short Message Service)
3 Hardware Overview
3.1 LMU-3640™
3.1.1 Environmental Specifications
3.1.2 Physical Specifications
3.2 Location Messaging Unit - LMU-3640™
3.3 LMU-3640™ Connectors
3.3.1 I/O Connector
3.3.2 VBUS Connector
3.3.3 Accessories
3.4 GPS Receiver
3.5 I/O Descriptions
3.5.1 3-Axis Accelerometer Input
3.5.2 Ignition and Inputs
3.5.3 Outputs
3.5.4 Status LEDs
4 Configuration and Activation
4.1 Quick Start - General Config
4.2 Activating LTE Using AT Commands
4.3 Auto provisioning of GSM or HSPA LMUs
4.4 Activating GSM or HSPA LMU using AT Commands
4.5 Preparing for Installation
4.6 Plan The Installation
4.6.1 Size and Placement of LMU Unit
4.6.2 Access to the SIM (Subscriber Identity Module) Card
4.6.3 Protection from Heat
4.6.4 Visibility of Diagnostic LEDs
4.6.5 Cable Length
4.6.6 Moisture and Weather Protection
4.6.7 Preventing Accidental or Unauthorized Modification
4.7 Installing the LMU in a Vehicle
4.7.1 Place the LMU unit in the vehicle.
4.7.2 Connect power, ignition, and ground.
4.7.3 Typical Connection Sequence
4.8 Installation Verification
4.8.1 Comm Verification
4.8.2 GPS Verification
4.8.3 Inbound Verification
4.8.4 Verification via SMS
LMU-3640 Hardware & Installation Guide
LMU-3640™
Hardware and Installation Guide
IMPORTANT: DO NOT INSTALL OR USE THE SOFTWARE OR DOCUMENTATION UNTIL YOU HAVE READ AND AGREED TO THE LICENSE AGREEMENT AND REVIEWED THE LIMITED WARRANTY AND REGULATORY INFORMATION.
1 Introduction
Welcome to the LMU-3640™ Hardware and Installation Guide. This manual is intended to give you information on the basic setup and installation of the CalAmp LMU-3640™ product(s) including hardware descriptions, environmental specifications, wireless network overviews and device installation.
1.1 About This Manual
The LMU-3640™ is one of the most flexible economy mobile tracking hardware products available. In order to accurately describe the functionality of these units we have broken this manual into the following sections:
System Overview – A basic description of a CalAmp LMU-3640™ based tracking system. This includes a description of roles and responsibilities of each of the CalAmp components as well as a brief overview of the wireless data technologies used by the LMU-3640™. Hardware Overview – Describes the physical characteristics and interfaces of the LMU-3640™. Installation and Verification – Provides guidance for the installation of the LMU-3640™ versions in a vehicle and instructions on how to verify the installation is performing adequately.
1.2 About The Reader
In order to limit the size and scope of this manual, the following assumptions have been made about the reader.
1. You are familiar with GPS concepts and terminology
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 1/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
2. You have some experience with installing equipment in vehicles
3. You are familiar with the use of AT Commands
4. You are familiar with the use of terminal programs such as HyperTerminal or PuTTY
1.3 About CalAmp
CalAmp is a leading provider of wireless communications products that enable anytime/anywhere access to critical information, data and entertainment content. With comprehensive capabilities ranging from product design and development through volume production, CalAmp delivers cost-effective high quality solutions to a broad array of customers and end markets. CalAmp is the leading supplier of Direct Broadcast Satellite (DBS) outdoor customer premise equipment to the U.S. satellite television market. The Company also provides wireless data communication solutions for the telemetry and asset tracking markets, private wireless networks, public safety communications and critical infrastructure and process control applications. For additional information, please visit the Company’s website at www.calamp.com (http://www.calamp.com/) .
1.4 About the CalAmp Location Messaging Unit - LMU-3640™
The CalAmp Location and Messaging unit-LMU-3640™ is a mobile device that resides in private, commercial or government vehicles. The LMU-3640™ is a single box enclosure incorporating a processor, a GPS receiver, a wireless data modem, and a vehicle-rated power supply. The LMU-3640™ also supports inputs and outputs to monitor and react to the vehicular environment and/or driver actions..
The LMU-3640™ collects, stores and transmits vehicular and location data over a designated wireless network including LTE and HSPA. Vehicular and location data are transmitted to a customized software application that has been designed to receive, acknowledge, process, store, and respond to this data.
Unit location and vehicular information is sent at pre-determined intervals, on demand, or when pre-programmed vehicular conditions are met. Transmission of data are sent immediately when in wireless network coverage and stored for later transmission when out of the wireless coverage area. SMS messaging can be used as an alternative or redundant communication backup.
The LMU-3640™ is designed to support a variety of custom fleet applications starting with basic automatic vehicle location and including applications requiring more sophisticated features such as geo-fencing, speed and mileage monitoring, third party security monitoring, dynamic reporting routines, and an array of exception alerts.
LMU-3640™ are sold exclusively to authorized systems integrators, software firms, and service providers who have developed their offering around the capabilities of the LMU-3640™. Customers are trained by CalAmp to integrate the mobile device with their system and to assist in support and maintenance of the devices.
Installations of LMU-3640™ are performed by CalAmp customers or contracted installers. Typical installations include hook-up to power, ignition, and ground. LMU-3640™s and the corresponding wiring are almost always hidden from view and general access. Placement of the units is usually under dashboards, in trunks or in compartments.
2 System Overview
2.1 Overview
The entire purpose behind a fleet management system is to be able to remotely contact a vehicle, determine its location or status, and do something meaningful with that information. This could include displaying the vehicle location on a map, performing an address look-up, providing real-time driving directions, updating the vehicles ETA, monitoring vehicle and driver status or dispatching the vehicle to its next pick up.
These functions, of course, are completely dependent on the capabilities of the vehicle management application. The role of the CalAmp LMU­3640™ is to deliver the location information when and where it is needed.
A typical fleet management system based on a CalAmp device includes the following components:
A wireless data network An LMU-3640™ Host Device (GPS NMEA only) An LM Direct™ communications server Backend mapping and reporting software which typically includes mapping and fleet reporting functions PULS™ LMU Manager™
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 2/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
2.2 Component Descriptions
2.2.1 Backend Software
Backend software is a customer provided software application. Regardless of its purpose one of its primary functions is to parse and present data obtained from the LM Direct server. This allows the application to do any of the following:
Display location data base on reports received from the LMU-3640™ in a variety of formats. Present historic information received from the LMU-3640™ typically in a report/chart style format Request location updates from one or more LMU-3640™ Update and change the configuration of one or more LMU-3640™
2.2.2 LMU Manager
LMU Manager is the primary support and configuration tool in the CalAmp system. It allows access to almost every feature available to the LMU-3640™. Unlike the backend software, it has the option of talking directly to an LMU-3640™ or making a request forwarded by the LM Direct server.
For further details on using LMU Manager, please refer to the LMU Manager Users Guide.
2.2.3 LM Direct Server
LM Direct is a message interface specification detailing the various messages and their contents the LMU-3640™ is capable of sending and receiving. This interface allows System Integrators to communicate directly with LMU-3640™s.
Sample code is available to system integrators upon request to aid in the development of an LM Direct Server.
2.2.4 Wireless Data Network
The Wireless Data Network provides the information bridge between the LM Direct server and the LMU-3640™s. Wireless data networks can take a variety of forms, such as cellular networks, satellite systems or local area networks. At this point in time, the networks available to the LMU-3640™ are:
HSPA
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 3/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
LTE
2.2.5 LMU-3640™
The LMU-3640™ is responsible for delivering the location and status information when and where it is needed. Data requests can come from any of the following sources:
PEG™ script within the LMU-3640™ A location or status request from the LM Direct server A location or status request from LMU Manager A request made from a host device such as a laptop, PDA or MDT
2.2.6 Host Device – Laptop/PDA or MDT
In some cases, it is necessary to run an application in the vehicle while it is being tracked by the backend software. Such examples could include instant messaging between vehicles or a central office, in-vehicle mapping or driving directions, email or database access. In most of these cases you will be using the LMU-3640™ as a wireless modem as well as a vehicle-location device.
2.3 Wireless Data Primer
This section is meant to give an overview of the wireless data technologies employed by the CalAmp location products.
2.3.1 SMS (Short Message Service)
“The Short Message Service (SMS) is the ability to send and receive text messages to and from mobile telephones. The text can comprise of words or numbers or an alphanumeric combination. SMS was created as part of the GSM Phase 1 standard.(Excerpt taken from the GSM World website (http://www.gsmworld.com/technology/sms/intro.shtml#1))
SMS message are typically text based, though binary messages are possible and can range in size from 140 characters to 256 characters depending on the network being used.
3 Hardware Overview
3.1 LMU-3640™
3.1.1 Environmental Specifications
The LMU-3640™ is designed to operate in environments typically encountered by fleet vehicles, including wide temperature extremes, voltage transients, and potential interference from other vehicle equipment.
To ensure proper operation in such an environment, LMU-3640™s were subjected to standard tests defined by the Society of Automotive Engineers (SAE). The specific tests included temperature, shock, vibration, and EMI/EMC. These tests were performed by independent labs and documented in a detailed test report. In accordance with Appendix A of SAE J1113 Part 1, the Unit is considered a “Functional Status Class B, Performance Region II” system that requires Threat Level 3 Testing.
The following shows the environmental conditions the LMU-3640™ is designed to operate in and the relevant SAE tests that were performed. No formal altitude tests were conducted.
Temperature
Operating Temperature Range: -30o C to 75o C Storage Temperature Range: -40o C to 80o C
SAE Test: SAE J1455
Humidity
95% relative humidity, 50° non-condensing SAE Test: SAE J1455
Altitude
Operates at altitudes of up to 10,000 feet and can be stored safely up to 40,000 feet
Shock and Vibration
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 4/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
Ground vehicle environment with associated shock and vibration SAE Test: SAE J1455 Mil Standard 202G and 810F
Bench-Handling (Non-Operating)
4 inch pivot drops on each of the faces on which it may be placed for servicing or installation. SAE Test: SAE J1455, SAE J1113 Mil Standard 810F
Electromagnetic Compatibility (EMC)
EMC compliant for a ground vehicle environment SAE Test: SAE J1113 Parts 2, 12, 21 and 41
Operating Voltage Range
The LMU-3640™ supports vehicles with 12 or 24 VDC systems including transients and electrical system noise.; this includes ranges from 9 to 30 VDC. SAE Test: SAE J1455, SAE J1113
Backup Battery
The LMU-3640™ supports a Lithium-Ion 1000 mAh backup battery input to be used when primary power is lost; the supported voltage range is 9 to 16 VDC
Transient Protection
Input voltage transients typical of large trucks SAE Test: SAE J1113 Part 11
Electrostatic Discharge (ESD)
No damage or performance degradation after the ESD disturbance. SAE Test: SAE J1113 Part 13
Power Consumption
Average: 100mA at 13.8 VDC Peak: 200mA for 50ms transmit burst (0.1% transmit duty cycle typical) Stand By 20mA
3.1.2 Physical Specifications
Dimensions
5.7”(L) x 2.1”(W) x 1.3”(H) 145mm (L) x 53mm (W) x 33mm (H)
Weight
5oz (140g)
Operating Temperature
-30° C to +75° C (connected to primary power)
-10° C to +60° C (When using internal battery power)
Storage Temperature
-40° C to +85° C 0° C to +30° C (Long Term w/Internal Battery)
Internal Battery Charging Temperature
+5° C to +45° C
Humidity
0% to 95% relative humidity, at 50° C non-condensing
Shock and Vibration
Ground vehicle environment with associated shock and vibration
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 5/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
SAE Test: SAE J1455 Mil Standard 202G and 810F
Operating Voltage Range
The LMU-3640™ supports vehicles with 12 or 24 VDC systems including transients and electrical system noise; this includes ranges from 7 to 32 VDC.
Electrostatic Discharge (ESD)
No damage or performance degradation after the ESD disturbance.
Power Consumption
Average: 70mA at 13.8 VDC Deep Sleep: 7mA @ 12V Sleep on Network (SMS): 10mA
3.2 Location Messaging Unit - LMU-3640™
3.3 LMU-3640™ Connectors
The LMU-3640™ offers 5 connectors to access power, I/O, serial communications and other expansion capabilities. These connectors are:
Primary Power Connector I/O Connector Serial Port Connector – Host/Aux1 Serial Port Connector – Aux 2
The block diagram has been removed LMU-3640™.
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 6/23
9/27/2017 LMU-3640 Hardware & Installation Guide - PULS Wiki
LMU-3640™ Connectors
3.3.1 I/O Connector
The LMU-3640™'s features expanded power and I/O capabilities via its 24-Pin Molex 43045-2202 connector. Its pin-out is as follows:
*Refer to the Harness Diagrams page for more information on appropriate accessories for the LMU-3640™.
https://puls.calamp.com/wiki/LMU-3640_Hardware_%26_Installation_Guide 7/23
Loading...