• Cutout height dimensions are different for
installations with an accessory storage drawer.
Make sure to use the correct cutout when preparing
the opening.
• Allow for clearance to adjacent corners, walls,
drawers, etc.
• Cabinets installed adjacent to wall ovens must have
an adhesion spec of at least 194ºF temperature
rating.
The oven must be securely installed in a cabinet that
is firmly attached to the house structure. Weight on
the oven door could cause the oven to tip and result
in injury. Never allow anyone to climb, sit, stand or
hang on the oven door.
If installing the drawer accessory, the drawer must
be assembled to the oven prior to installation into
the cabinet. See the Accessory Storage Drawer
Assembly Instructions.
31-2000354 Rev.03
Installation Preparation
ELECTRICAL REQUIREMENTS
Single Advantium Built-In Oven Installation:
This product requires a 120-volt, 60 Hz, 15-amp
circuit and draws 1.8 kilowatts. This product must be
connected to a supply circuit of the proper voltage and
frequency.
• Wire size must conform to the requirements of the
National Electrical Code or the prevailing local code for
this kilowatt rating.
• The power supply cord and plug should be brought
to a separate 15 or 20 ampere branch circuit single
grounded receptacle. The outlet box should be located
within reach of the 48” power cord.
ELECTRICAL LOCATION
6”
9”
Locate outlet box in the shaded area
Install a recessed electrical outlet
in the back wall of the opening
within 6Ǝ of either side and at least
9Ǝ above the cutout floor.
GROUNDING INSTRUCTIONS
WARNING
Ensure Proper ground
exists before use.
power cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded.
Consult a qualified electrician or service technician if
the GROUNDING INSTRUCTIONS are not completely
understood, or if doubt exists as to whether the
Improper use of the grounding plug can result in a risk of electric shock.
This appliance must be grounded.
In the event of an electrical short
circuit, grounding reduces the risk
of electric shock by providing an
escape wire for the electric current.
This appliance is equipped with a
appliance is properly grounded.
If the outlet is a standarf 2-prong wall outlet, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
Do not under any circumstacnes cut or remove the third
(ground) prong from the power cord.
Do not use an extension cord. If the power cord is too
short, have a qualified electrician or service technician
install an outlet near the appliance.
For best operation, plug this appliance into its own
electrical outlet to prevent flickering of lights, blowing of
fuse or tripping of circuit breaker.
431-2000354 Rev. 0
Standard Installation Preparation
PREPARE THE OPENING
Advantium Built-In Oven can be installed in
combination with other Built-In appliances. Always
follow each product’s Installation Instructions to
complete the installation.
Single Advantium Built-In Oven Installation:
Order a 30” wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
30”
17-1/2”
36-3/4”
Min.
23-1/2”
25-1/4”
Construct
solid bottom
- Min. 3/8”
plywood
supported
on all four
sides. Must
be able to
support
weight of
oven and
contents.
PREPARE THE OPENING (CONT.)
Installation over a Warming Drawer:
30”
17-1/2”
36-3/4”
Min.
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven supports
above the Warming Drawer location does not obstruct
the required interior depth and height. See Warming
Drawer installation instructions for details.
23-1/2”
25-1/4”
Construct
solid bottom
- Min. 3/8”
plywood
supported
on all four
sides. Must be
able to support
weight of oven
and contents.
2” Min.
(3” Recommended)
Per Warming
Drawer
Requirement
• Allow 2-1/4” case trim overlap at the
top and 1” overlap on the bottom and 2-1/4” overlap
for each side of the opening.
• Oven overlaps will conceal cut edges on all sides of
the opening.
When installed over a single oven or a warming
drawer, allow at least 2” between the two openings.
This separation will provide clearance for bottom
overlap of the Advantium 120 and the other
appliance overlaps.
• The support must be level and rigidly mounted, flush
with the bottom edge of the cutout.
31-2000354 Rev.05
Standard Installation Preparation
PREPARE THE OPENING (CONT.)
Installation over a Wall Oven:
Construct
solid bottom
- Min. 3/8”
plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
2” Min.
(3” Recommended)
Per Oven
Requirement
45-1/4”
Min.
30”
17-1/2”
23-1/2”
25-1/4”
PREPARE THE OPENING (CONT.)
Installation over a Wall Oven and Warming
Drawer:
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by
2x4 or 2x2
Runners all
Four Sides
2” Min.
(3” recommended)
Per Oven
Requirement
2” Min.
45-1/4”
Min.
30”
17-1/2”
23-1/2”
25-1/4”
• If you are replacing an electric double oven with the
combined installation of an Advantium Built-In Oven
and a single oven, use the dimensions shown. The
middle rail separating the two openings may need to
be larger than the 2” minimum shown.
Per warming drawer requirement
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven supports
above the Warming Drawer location does not obstruct
the required interior depth and height. See Warming
Drawer installation instructions for details.
CAUTION
mounting surface must be capable of supporting the
cabinet load, in addition to the added weight of the
oven and drawer, plus additional oven loads.
For personal safety, the
631-2000354 Rev. 0
Standard Installation Preparation
PREPARE THE OPENING (CONT.)
Installation over another Advantium Built-In
Oven:
30Ǝ
17-1/2Ǝ
17-1/2Ǝ
23-1/2Ǝ
25-1/4Ǝ
Construct
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
2 1/2Ǝ Min.
(3 1/2Ǝ Recommended)
PREPARE THE OPENING (CONT.)
Installation under a Microwave Oven and over
a Warming Drawer:
Construct
30Ǝ
Per Microwave
Oven Requirement
17-1/2Ǝ
Per Warming
Drawer
Requirement
23-1/2Ǝ
25-1/4Ǝ
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
3.5Ǝ Min.
(4.5Ǝ Recommended)
2Ǝ Min.
(3Ǝ Recommended)
• If you are mounting a GE Appliances Appliances/
Monogram Built-In
use the dimensions
separating the two openings may need to be larger
than the 2Ǝ minimum shown.
Advantoum Oven over another,
shown. The middle rail
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct
the required interior depth and height. See Warming
Drawer installation instructions for details.
CAUTION
mounting surface must be capable of supporting the
cabinet load, in addition to the added weight of the
oven and drawer, plus additional oven loads.
For personal safety, the
31-2000354 Rev.07
Standard Installation Preparation
PREPARE THE OPENING (CONT.)
Installation beside another Advantium Built-In
Oven:
• If you are mounting an Advantium Built-In
another, use the dimensions shown. The middle rail
separating the two openings may need to be larger
than the 4-1/2Ǝ minimum shown.
Oven
beside
25-1/4Ǝ
17-1/2Ǝ
23-1/2Ǝ
25-1/4Ǝ
17-1/2Ǝ
4-1/2Ǝ Min.
(5-1/2Ǝ Recommended)
PREPARE THE OPENING (CONT.)
Installation under an Advantium 30Ǝ or 36Ǝ Cooktop or Countertop:
Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for the cutout size.
See the label on top of the oven for approved cooktop models. This oven requires a separate, properly grounded
15-Amp, 120-Volt, 60Hz power supply. The cooktop requires a separate power supply. Use a 36Ǝ or wider base
cabinet.
Cooktop
Cooktop
1-1/2Ǝ Min.
25Ǝ
36Ǝ
Countertop
Height
Ǝ
Cooktop height including depth
of electrical box on some
models. Refer to cooktop
installation instructions.
No minimum clearance required
between cooktop and oven.
23-1/2
4Ǝ High
Toekick
17-1/2
25-1/4Ǝ
Ǝ
831-2000354 Rev. 0
Flush Mount Installation Preparation
PREPARE THE INTERIOR
Cut and install side cleats:
• Cut side wood cleats to height of cabinet opening
and approx. 2-1/2” in depth. Install, on each side,
1-3/8” from the front face of the cabinet.
Cut and install bottom cleat:
• Cut bottom wood cleat to a height of 1-1/8”, a depth
of the cabinet minus 1-3/8” and a width of 25-1/4”
to fit between side cleats. Install onto the cabinet
floor between the side cleats, push it all the way
back against cabinet wall and make sure its front face
aligns with the front faces of the side cleats (1-3/8”
gap from the front cabinet face).
AA
C
B
D
E
PREPARE THE OPENING
The Advantium Built-In Oven can be installed
in combination with other Advantium Built-In
ovens. Always follow each product’s Installation
Instructions to complete the installation.
Single Advantium Built-In Oven
Installation:
Cut the opening in a cabinet to the dimensions
shown.
23-1/2” min.
F *
**20 5/8”
Construct
solid bottom
- Min. 3/8”
plywood
supported on
all four sides.
Must be able to
support weight
of oven and
contents.
ASide cleats depth2-1/2” min.
BBottom cleat height1-1/8”
CBottom cleat depthCabinet depth minus 1-3/8”
DBottom cleat width25-1/4”
EAll three cleats1 1/4”
D
TOP
C
VIEW
AA
Front Face of Cabinet
EE
36-3/4”
Min.
• The support must be level and rigidly mounted,
flush with the bottom edge of the cutout.
Approved Flush Installation
Single Advantium30”30-1/4”
Over Warming Drawer30”30-1/4”
Over Oven
Over Oven and Warming Drawer
Over Advantium Built-In Oven
Double Advantium (side by side)
Under Cooktop or CountertopSee page 10
Dimension F
1/8” Reveal 1/4” Reveal
30”30-1/4”
30”30-1/4”
30”30-1/4”
See page 10
** Top and bottom reveals are set to 1/8”.
31-2000354 Rev.09
Flush Mount Installation Preparation
PREPARE THE OPENING
The Advantium Built-In Oven can be installed beside
another Advantium Built-In Oven in a side-by-side
combination.
Double Advantium Built-In Oven
Installation:
Cut the opening in a cabinet to the dimensions shown.
• Center divider acts as cleat for side of each respective
unit. Only one additional side cleat needed per oven
cutout.
• The support must be level and rigidly mounted, flush
with the bottom edge of the cutout.
Dimension 1/8” Reveal1/4” Reveal
G59-7/8”60-1/4”
H5-1/8”5-1/4”
I27-3/8”27-1/2”
36-3/4”
Min.
23-1/2” min.
G*
H*
I*
I*
20 5/8”
1 1/4”
Construct solid bottom
- Min. 3/8” plywood
supported on all four
sides. Must be able
to support weight of
oven and contents.
PREPARE THE OPENING
Installation under an Advantium 30Ǝ or 36Ǝ Cooktop or Countertop:
Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for the cutout size.
See the label on top of the oven for approved cooktop models. This oven requires a separate from the cooktop,
properly grounded 15-Amp, 120-Volt, 60Hz power supply. Use a 36Ǝ or wider base cabinet.
23-1/2
1-1/2Ǝ Min.
Cooktop
Cooktop
20-5/8”
J*
Ǝ
25Ǝ
36Ǝ
Countertop
Height
Cooktop height including
depth of electrical box
on some models. Refer
to cooktop installation
instructions.
No minimum clearance
required between cooktop
and oven.
*1/8” reveals on
sides and top
4Ǝ High
Toekick
*See table for desired reveals on sides.
Dimension1/8” Reveal1/4” Reveal
J30”30-1/4”
1031-2000354 Rev. 0
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.