CGU486SDLSS
22 3/4" Min.
7/8"
2 1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
Non-
combustible
material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
Front of deep cabinets can align with control
panel beveled edge.
Rangetop
1/2" Above Adjacent
Countertops
13" Max.
18" Min.
22 3/4" Min.
46 1/4"
7/8"
*48"
2 1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
48" Minimum
to Combustibles
Non-
combustible
material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
47 7/8" Width
GE Café™ Series 48" Professional Gas Rangetop with
6 Burners and Griddle (Natural Gas)
DIMENSIONS AND INSTALLATION INFORMATION
Professional rangetops offer a number of choices in
size and rangetop configurations.
PRODUCT DIMENSIONS AND CLEARANCE:
A suitable overhead vent hood is required for models
with a grill and is recommended for all other models.
Due to the high heat capacity of this unit, particular
attention should be paid to the hood and ductwork
installation to assure it meets local building codes.
Clearances between rangetop and side wall or
combustible material must be at least 12" on
each side.
Allow 8" free space below the top surface of countertop.
Allow additional clearances below the burner box
to install the regulator and make house gas supply
connections. Use a 90° elbow to route the gas
connections and limit interference with drawers or other
cabi net ry.
* The opening between a 4" high backsplash must be
36" to allow the rangetop to slide back against the wall.
WAR N I N G : Installations without a hood require
48" minimum to combustibles above the rangetop.
A custom hood installation with exposed horizontal
combustible surfaces must have an “auto-on” feature.
Refer to hood installation instructions for specific
hood clearances. The surface of the entire back wall
above the countertop and below the hood must be
covered with a non-combustible material such as
metal, ceramic tile, brick, marble or other stone.
27 1/2" to
47 7/8" Width
Rangetop
1/2" Above Adjacent
Countertops
Control panel projects forwards from
Front of
Bullnose
standard depth cabinets.
Rangetop
1/2" Above Adjacent
Countertops
Front of deep cabinets can align with control
8 1/2"
Height
13" Max.
18" Min.
48" Minimum
to Combustibles
*48"
46 1/4"
22 3/4" Min.
Noncombustible
material
48"
12" Min.
Each Side
12" Minimum to
Adjacent Wall
7/8"
2 1/2"
8"
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 6/17
CGU486SDLSS
GE Café™ Series 48" Professional Gas Rangetop with
6 Burners and Griddle (Natural Gas)
DIMENSIONS AND INSTALLATION INFORMATION
BACKSPLASH ACCESSORIES: The rangetop requires a 12" minimum
clearance to a vertical combustible surface at the rear. A backsplash
is required for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-combustible
backsplash can be used.
UXADJB48PSS, 48" backsplash with shelf
BACKSPLASH WITH WARMING SHELF: All Professional Hoods
feature infrared warming lights. The 30"-36" adjustable backsplash with
warming shelf is a perfect complement when installed with the tapered or
straight-sided hoods.
- Restaurant-Style Professional Hoods are shipped with a 22" stainless
steel backsplash and warming shelf.
ADVANCE PLANNING FOR PROFESSIONAL RANGETOPS:
Professional rangetops offer a number of choices in size and rangetop
configurations.
- All Professional rangetops are factory set for natural or liquid propane
gas. The correct model should be ordered for the installation situation.
NOTE: Conversion kits are included with the rangetop if the wrong gas
type was ordered. High Altitude kit, WB28K10553, is also available. The
kits must be installed by a qualified service technician at additional cost.
Side View with a Backsplash
Universal Utility Locations
ELECTRICAL REQUIREMENTS: Rangetops must be supplied with
120V, 60Hz, and connected to an individual, properly grounded branch
circuit protected by a 15 amp circuit breaker or time-delay fuse.
GAS SUPPLY:
- Natural gas models are designed to operate at 5" water column
pressure. For proper operation, the pressure of the natural gas supplied
to the regulator must be between 7" and 13" water column.
- The liquid propane models are designed to operate at 10" water
column pressure. For proper operation, the pressure of the LP source
to the regulator must be between 11" and 13" water column.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 6/17