Cafe CGU486SDLSS Specifications

CGU486SDLSS
panel beveled edge.
22 3/4" Min.
7/8"
2 1/2"
48"
8"
12" Minimum to Adjacent Wall
12" Min. Each Side
Non- combustible material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
Front of deep cabinets can align with control panel beveled edge.
Rangetop
1/2" Above Adjacent Countertops
13" Max.
18" Min.
22 3/4" Min.
46 1/4"
7/8"
*48"
2 1/2"
48"
8"
12" Minimum to Adjacent Wall
12" Min. Each Side
48" Minimum to Combustibles
Non- combustible material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
47 7/8" Width
GE Café™ Series 48" Professional Gas Rangetop with 6 Burners and Griddle (Natural Gas)
DIMENSIONS AND INSTALLATION INFORMATION
Professional rangetops offer a number of choices in size and rangetop configurations.
PRODUCT DIMENSIONS AND CLEARANCE: A suitable overhead vent hood is required for models with a grill and is recommended for all other models. Due to the high heat capacity of this unit, particular attention should be paid to the hood and ductwork installation to assure it meets local building codes.
Clearances between rangetop and side wall or combustible material must be at least 12" on each side.
Allow 8" free space below the top surface of countertop. Allow additional clearances below the burner box to install the regulator and make house gas supply connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabi net ry.
* The opening between a 4" high backsplash must be 36" to allow the rangetop to slide back against the wall.
WAR N I N G : Installations without a hood require 48" minimum to combustibles above the rangetop. A custom hood installation with exposed horizontal combustible surfaces must have an “auto-on” feature. Refer to hood installation instructions for specific hood clearances. The surface of the entire back wall above the countertop and below the hood must be covered with a non-combustible material such as metal, ceramic tile, brick, marble or other stone.
27 1/2" to
47 7/8" Width
Rangetop
1/2" Above Adjacent Countertops
Control panel projects forwards from
Front of
Bullnose
standard depth cabinets.
Rangetop
1/2" Above Adjacent Countertops
Front of deep cabinets can align with control
8 1/2"
Height
13" Max.
18" Min.
48" Minimum to Combustibles
*48"
46 1/4"
22 3/4" Min.
Non­combustible material
48"
12" Min. Each Side
12" Minimum to Adjacent Wall
7/8"
2 1/2"
8"
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 6/17
CGU486SDLSS
GE Café™ Series 48" Professional Gas Rangetop with 6 Burners and Griddle (Natural Gas)
DIMENSIONS AND INSTALLATION INFORMATION
BACKSPLASH ACCESSORIES: The rangetop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used.
UXADJB48PSS, 48" backsplash with shelf
BACKSPLASH WITH WARMING SHELF: All Professional Hoods feature infrared warming lights. The 30"-36" adjustable backsplash with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods.
- Restaurant-Style Professional Hoods are shipped with a 22" stainless steel backsplash and warming shelf.
ADVANCE PLANNING FOR PROFESSIONAL RANGETOPS:
Professional rangetops offer a number of choices in size and rangetop configurations.
- All Professional rangetops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
NOTE: Conversion kits are included with the rangetop if the wrong gas type was ordered. High Altitude kit, WB28K10553, is also available. The kits must be installed by a qualified service technician at additional cost.
Side View with a Backsplash
Universal Utility Locations
ELECTRICAL REQUIREMENTS: Rangetops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse.
GAS SUPPLY:
- Natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
- The liquid propane models are designed to operate at 10" water column pressure. For proper operation, the pressure of the LP source to the regulator must be between 11" and 13" water column.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 6/17